Ferry Kienberger

Dr. Ferry Kienberger

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2015 in Nanoscale
Verified
Journal Article
Open access
PDF file
EBEnrico Brinciotti
Enrico Brinciotti
GGGeorg Gramse
Georg Gramse
SHSoeren Hommel
Soeren Hommel
TSThomas Schweinboeck
Thomas Schweinboeck
AAAndreas Altes
Andreas Altes
FKFerry Kienberger
Ferry Kienberger
We present a new method to extract resistivity and doping concentration of semiconductor materials from Scanning Microwave Microscopy (SMM) S11 reflection measurements. Using a three error parameters de-embedding workflow, the S11 raw data are converted into calibrated capacitance and resistance images where no calibration sample is required. The SMM capacitance and resistance values were measured at 18 GHz and ranged from 0 to 100 aF and from 0 to 1 MΩ, respectively. A tip–sample analytical model that includes tip radius, microwave penetration skin depth, and semiconductor depletion layer width has been applied to extract resistivity and doping concentration from the calibrated SMM resistance. The method has been tested on two doped silicon samples and in both cases the resistivity and doping concentration are in quantitative agreement with the data-sheet values over a range of 10−3 Ω cm to 101 Ω cm, and 1014 atoms per cm3 to 1020 atoms per cm3, respectively. The measured dopant density values, with related uncertainties, are [1.1 ± 0.6] × 1018 atoms per cm3, [2.2 ± 0.4] × 1017 atoms per cm3, [4.5 ± 0.2] × 1016 atoms per cm3, [4.5 ± 1.3] × 1015 atoms per cm3, [4.5 ± 1.7] × 1014 atoms per cm3. The method does not require sample treatment like cleavage and cross-sectioning, and high contact imaging forces are not necessary, thus it is easily applicable to various semiconductor and materials science investigations.

19 February 2016 in Nanotechnology
Verified
Journal Article
Open access
PDF file
STSilviu-Sorin Tuca
Silviu-Sorin Tuca
GBGiorgio Badino
Giorgio Badino
GGGeorg Gramse
Georg Gramse
EBEnrico Brinciotti
Enrico Brinciotti
MKManuel Kasper
Manuel Kasper
FKFerry Kienberger
Ferry Kienberger
The application of scanning microwave microscopy (SMM) to extract calibrated electrical properties of cells and bacteria in air is presented. From the S 11 images, after calibration, complex impedance and admittance images of Chinese hamster ovary cells and E. coli bacteria deposited on a silicon substrate have been obtained. The broadband capabilities of SMM have been used to characterize the bio-samples between 2 GHz and 20 GHz. The resulting calibrated cell and bacteria admittance at 19 GHz were Y cell = 185 μS + j285 μS and Y bacteria = 3 μS + j20 μS, respectively. A combined circuitry-3D finite element method EMPro model has been developed and used to investigate the frequency response of the complex impedance and admittance of the SMM setup. Based on a proposed parallel resistance–capacitance model, the equivalent conductance and parallel capacitance of the cells and bacteria were obtained from the SMM images. The influence of humidity and frequency on the cell conductance was experimentally studied. To compare the cell conductance with bulk water properties, we measured the imaginary part of the bulk water loss with a dielectric probe kit in the same frequency range resulting in a high level of agreement.

16 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AMAmin Moradpour
Amin Moradpour
MKManuel Kasper
Manuel Kasper
JHJohannes Hoffmann
Johannes Hoffmann
FKFerry Kienberger
Ferry Kienberger
Electrochemical impedance spectroscopy (EIS) is a widely used method for battery tests in manufacturing and automotive field applications. As such, accurate measurement of the impedance over a broad frequency spectrum is of high relevance, also requiring specific calibration methods and evaluation of error bounds. Here, we report for the first time a comprehensive uncertainty analysis of calibrated EIS for batteries. We aim to identify two uncertainty sources, the fixture repeatability and measurement noise, and evaluate their effect on the measured impedances. To this end, an error model assigned to each of them and the real and imaginary parts of the model parameters are characterized in the frequency range of 100 mHz–5 kHz by performing specific impedance measurements on a shunt resistor and a short standard. We demonstrate how different uncertainties are combined with the measured impedances, incorporating also the impedance calibration procedure. The errors are propagated through the calibration and correction functions by applying the linear error propagation method provided by the UncLib package from METAS. The error bounds are derived from uncertainty propagation in the shunt standard and the prismatic battery cell EIS and verified by conducting a series of measurements. Thereby, the uncertainty is shown as ellipsoids in every frequency point of the Nyquist plot. For instance, at 1 Hz, the 34-Ah prismatic cell shows a calibrated real-part impedance and two standard deviation error bounds of 1.07 $\text{m}\Omega $ ± $26~ \mu \Omega $ .

24 September 2021 in Batteries
Verified
Journal Article
Open access
PDF file
LHLouisa Hoffmann
Louisa Hoffmann
MKManuel Kasper
Manuel Kasper
MKMaik Kahn
Maik Kahn
GGGeorg Gramse
Georg Gramse
Gabriela Ventura SilvaGabriela Ventura Silva
Gabriela Ventura Silva
FKFerry Kienberger
Ferry Kienberger
Lithium-ion batteries are a key technology for electromobility; thus, quality control in cell production is a central aspect for the success of electric vehicles. The detection of defects and poor insulation behavior of the separator is essential for high-quality batteries. Optical quality control methods in cell production are unable to detect small but still relevant defects in the separator layer, e.g., pinholes or particle contaminations. This gap can be closed by executing high-potential testing to analyze the insulation performance of the electrically insulating separator layer in a pouch cell. Here, we present an experimental study to identify different separator defects on dry cell stacks on the basis of electric voltage stress and mechanical pressure. In addition, finite element modeling (FEM) is used to generate physical insights into the partial discharge by examining the defect structures and the corresponding electric fields, including topographical electrode roughness, impurity particles, and voids in the separator. The test results show that hard discharges are associated with significant separator defects. Based on the study, a voltage of 350 to 450 V and a pressure of 0.3 to 0.6 N/mm2 are identified as optimum ranges for the test methodology, resulting in failure detection rates of up to 85%.

11 October 2023 in Energy Reports
Verified
Journal Article
Open access
NRNawfal Al-Zubaidi R-Smith
Nawfal Al-Zubaidi R-Smith
MMManuel Moertelmaier
Manuel Moertelmaier
GGGeorg Gramse
Georg Gramse
MKManuel Kasper
Manuel Kasper
MRMykolas Ragulskis
Mykolas Ragulskis
FKFerry Kienberger
Ferry Kienberger

27 March 2006 in ChemBioChem
Verified
Journal Article
Closed access
PDF file
Andreas EbnerAndreas Ebner
Andreas Ebner
FKFerry Kienberger
Ferry Kienberger
CHCarina Huber
Carina Huber
AKA. S. M. Kamruzzahan
A. S. M. Kamruzzahan
VPVassili Ph. Pastushenko
Vassili Ph. Pastushenko
PHPeter Hinterdorfer
Peter Hinterdorfer