Yuping Li

Dr. Yuping Li


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in Environmental Science & Technology
Verified
Journal Article
Closed access
CSChunlei Su
Chunlei Su
THThomas Horseman
Thomas Horseman
HCHongbin Cao
Hongbin Cao
KCKofi S.S. Christie
Kofi S.S. Christie
YLYuping Li
Yuping Li
SLShihong Lin
Shihong Lin

10 December 2018 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
KTKexin Tang
Kexin Tang
SYSotira Yiacoumi
Sotira Yiacoumi
YLYuping Li
Yuping Li
CTCostas Tsouris
Costas Tsouris

1 May 2014 in Journal of Environmental Sciences
Verified
Journal Article
Closed access
FDFeng Duan
Feng Duan
YYYuezhu Yang
Yuezhu Yang
YLYuping Li
Yuping Li
HCHongbin Cao
Hongbin Cao
YWYi Wang
Yi Wang
YZYi Zhang
Yi Zhang

1 April 2015 in Chemosphere
Verified
Journal Article
Closed access
FDFeng Duan
Feng Duan
YLYuping Li
Yuping Li
HCHongbin Cao
Hongbin Cao
YWYi Wang
Yi Wang
JCJohn C. Crittenden
John C. Crittenden
YZYi Zhang
Yi Zhang

8 November 2017 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
KTKexin Tang
Kexin Tang
JCJunjun Chang
Junjun Chang
HCHongbin Cao
Hongbin Cao
CSChunlei Su
Chunlei Su
YLYuping Li
Yuping Li
YZYi Zhang
Yi Zhang

29 November 2019 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
JCJunjun Chang
Junjun Chang
FDFeng Duan
Feng Duan
CSChunlei Su
Chunlei Su
YLYuping Li
Yuping Li
HCHongbin Cao
Hongbin Cao
Non-carbon materials in capacitive deionization (CDI) can help to enhance the capacity of removed ions. Here, we report for the first time the removal of chloride ions (Cl−) with a bismuth (Bi) anode when coupled with an activated carbon (AC) cathode in CDI. The effects of carbon black in the Bi electrode, applied voltage, electrode mass loading and initial concentration on Cl− removal are investigated. Moreover, its cycle performance is also tested. Results show that addition of carbon black to a Bi electrode (Bi@CB) significantly improves Cl− removal. The declining trend of Cl− concentration and appearance of peaks assigned to products of bismuth oxychloride (BiOCl) in XRD patterns confirm Cl− storage by the Bi electrode, which is enhanced with an increase in voltage. When coupled with AC in a fixed mass, increasing the Bi mass does not contribute to more Cl− removal. Although the cycle performance is not excellent (the attenuation rate is 74% after 10 cycles), its chloride removal capacity is ∼2–3 times the value of AC (e.g. 0.95 vs. 0.32 mmol gBi −1 at 1.2 V in 500 mg L−1 NaCl solution). Besides, the Bi–AC electrode pair in CDI is more suitable to remove Cl− from a solution with a Cl− concentration of below 600 mg L−1.