27 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
JCJongmin Cheon
Jongmin Cheon
JKJinwook Kim
Jinwook Kim
JLJoohoon Lee
Joohoon Lee
KLKichang Lee
Kichang Lee
YCYoungkiu Choi
Youngkiu Choi
This paper deals with the development of a wind turbine pitch control system and the construction of a Hardware-in-the-Loop-Simulation (HILS) testbed for the performance test of the pitch control system. When the wind speed exceeds the rated wind speed, the wind turbine pitch controller adjusts the blade pitch angles collectively to ensure that the rotor speed maintains the rated rotor speed. The pitch controller with the individual pitch control function can add individual pitch angles into the collective pitch angles to reduce the mechanical load applied to the blade periodically due to wind shear. Large wind turbines often experience mechanical loads caused by wind shear phenomena. To verify the performance of the pitch control system before applying it to an actual wind turbine, the pitch control system is tested on the HILS testbed, which acts like an actual wind turbine system. The testbed for evaluating the developed pitch control system consists of the pitch control system, a real-time unit for simulating the wind and the operations of the wind turbine, an operational computer with a human–machine interface, a load system for simulating the actual wind load applied to each blade, and a real pitch bearing. Through the several tests based on HILS test bed, how well the pitch controller performed the given roles for each area in the entire wind speed area from cut-in to cut-out wind speed can be shown.

1 July 2006
Verified
Conference Paper
Closed access
JCJongmin Cheon
Jongmin Cheon
CKChoon-Kyoug Kim
Choon-Kyoug Kim
JLJong-Moo Lee
Jong-Moo Lee
SKSoonman Kwon
Soonman Kwon
In this paper, we introduce a new method for detecting failures of a power converter module in control rod control system of a nuclear power plant. The failure called the phase failure and occurring in a power converter module can exert harmful influence upon the operation of the associated control rod drive mechanism for driving neutron-absorbing control rods controlling the thermal output of the reactor. Because of this adverse condition, it is necessary that the phase failure should be detected quickly and correctly. We devised a new method for detecting the phase failure for the digital power controller and solved the drawbacks of the existing failure detector