Richard Kouitat Njiwa

Dr. Richard Kouitat Njiwa


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
BKBlagoj KARAKASHOV
Blagoj KARAKASHOV
MTM’barek Taghite
M’barek Taghite
RNRichard Kouitat Njiwa
Richard Kouitat Njiwa
Vanessa FierroVanessa Fierro
Vanessa Fierro
Alain CelzardAlain Celzard
Alain Celzard
The ability of various commercial fibrous carbon materials to withstand stress and conduct heat has been evaluated through experimental and analytical studies. The combined effects of different micro/macro-structural characteristics were discussed and compared. Large differences in mechanical behavior were observed between the different groups or subgroups of fibrous materials, due to the different types of fibers and the mechanical and/or chemical bonds between them. The application of the Mooney–Rivlin model made it possible to determine the elastic modulus of soft felts, with a few exceptions, which were studied in-depth. The possible use of two different mechanical test methods allowed a comparison of the results in terms of elastic modulus obtained under different deformation regimes. The effective thermal conductivity of the same fibrous materials was also studied and found to be much lower than that of a single carbon fiber due to the high porosity, and varied with the bulk density and the fiber organization involving more or less thermal contact resistances. The thermal conductivity of most materials is highly anisotropic, with higher values in the direction of preferential fiber orientation. Finally, the combination of compression and transient thermal conductivity measurement techniques allowed the heat conduction properties of the commercial fibrous carbons to be investigated experimentally when compressed. It was observed that thermal conductivity is strongly affected under compression, especially perpendicular to the main fiber orientation.

1 July 2022 in Materials
Verified
Journal Article
Open access
PDF file
ATAlex TCHINDA
Alex TCHINDA
LCLaëtitia CHEZEAU
Laëtitia CHEZEAU
GPGaël PIERSON
Gaël PIERSON
RNRichard Kouitat Njiwa
Richard Kouitat Njiwa
BRBertrand H Rihn
Bertrand H Rihn
PBPierre Bravetti
Pierre Bravetti
The osseointegration of implants is defined as the direct anatomical and functional connection between neoformed living bone and the surface of a supporting implant. The biological compatibility of implants depends on various parameters, such as the nature of the material, chemical composition, surface topography, chemistry and loading, surface treatment, and physical and mechanical properties. In this context, the objective of this study is to evaluate the biocompatibility of rough (Ra = 1 µm) and smooth (Ra = 0 µm) surface conditions of yttria–zirconia (Y-TZP) discs compared to pure zirconia (ZrO2) discs by combining a classical toxicological test, morphological observations by SEM, and a transcriptomic analysis on an in vitro model of human Saos-2 bone cells. Similar cell proliferation rates were observed between ZrO2 and Y-TZP discs and control cells, regardless of the surface topography, at up to 96 h of exposure. Dense cell matting was similarly observed on the surfaces of both materials. Interestingly, only 110 transcripts were differentially expressed across the human transcriptome, consistent with the excellent biocompatibility of Y-TZP reported in the literature. These deregulated transcripts are mainly involved in two pathways, the first being related to “mineral uptake” and the second being the “immune response”. These observations suggest that Y-TZP is an interesting candidate for application in implantology.

23 February 2024 in Crystals
Verified
Journal Article
Open access
PDF file
MKMonika Kušter
Monika Kušter
ZSZoran Samardžija
Zoran Samardžija
Matej KomeljMatej Komelj
Matej Komelj
Miroslav HuskićMiroslav Huskić
Miroslav Huskić
Marko BekMarko Bek
Marko Bek
SŠSašo Šturm
Sašo Šturm
We examined the effect of Al59Cu25Fe13B3 (at.%) quasicrystalline (QC) reinforcement particles on the mechanical and surface properties of a polymer-matrix composite by applying a technical polymer polyphthalamide (PPA). The observed increase in the tensile Young’s modulus ranged from 1810 MPa for the pure polymer to 4114 MPa for the composite with a QC filling of 35 vol.%. The elongation at fracture decreased with the filling fraction, being equal to 16.9% for a pure polymer and dropping to 4.8% for the composite with a QC filling of 35 vol.%. The same trend was noticeable with flexural Young’s modulus, which ranged from 100 MPa for a pure polymer to 125.5 MPa for the composite with 35 vol.% of QC. It was found that the increase in the mechanical strength led to a simultaneous increase of brittleness, which was reflected in a decrease of the impact strength for a pure polymer from 98.5 kJ/m2 to 42.4 kJ/m2 for composites with a QC filling of 35 vol.%. In contrast, when filled with 5 vol.% of QC, the impact strength increased by 8%. The friction coefficient against 100C6 steel dropped from 0.15 for pure PPA down to 0.10 for 5 vol.% of the QC filling, followed by an increase to 0.26 for further QC fillings up to 35 vol.%. Interestingly, a local minimum of friction was achieved at filling factors between 5 to 20 vol.% of QC. Independently, a clear surfenergy minimum was also found for the composite material with 20 vol.% of QC filling associated with a net drop in the polar component of the surfenergy. Surfenergy refers to the surface energy related to the top of the oxide layer under ambient conditions. We hypothesise that this is related to the percolation threshold at about 13 vol.% QC, reflected in the observed behaviour of both the friction coefficient and surfenergy. For the pure QC annealed in air for 1 h at 500 °C significant wear tracks were observed accompanied by a wear debris formation. On the other hand, a pure polymer exhibited slightly visible wear tracks with no apparent debris formation, and for the composites with different QC filling factors, the wear traces were barely visible with negligible debris formation.

28 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
ATAlex Pérez TCHINDA
Alex Pérez TCHINDA
GPGaël PIERSON
Gaël PIERSON
RNRichard Kouitat Njiwa
Richard Kouitat Njiwa
PBPierre Bravetti
Pierre Bravetti
The success of titanium dental implants depends on their osseointegration into the bone, which is determined by the composition and surface properties of the implant in close contact with the bone. There is a wide variety of implants on the market. Is it possible to identify the implant with the best composition and surface topography for optimal osseointegration? To this aim, 13 brands of dental implants from nine distinct manufacturers have been selected and their composition and surface topography determined. The obtained results show differences between these implants, in this case, the Ssk averages of the three measurements performed on each implant were positive, or 0.4 (0.1–0.8), indicating that the roughness of all implants analyzed was primarily textured and not flat. Like Sa, we found the highest Sdr for implants subjected only to sandblasting. In addition, only the ALS-active® implant had a modified microstructure on its surface. However, analysis of the NANOTITE implant surface revealed a 1.40% presence of calcium which we consider too low to have an effect on bone formation around the implant. As a result, we have also highlighted the lack of a recognized independent standard for dental implant surface conditions and the lack of independent quality control vis-à-vis manufacturers. Of all the surface types studied, none proved more satisfactory than another.

20 September 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
ATAlex TCHINDA
Alex TCHINDA
ALAugustin Lerebours
Augustin Lerebours
RNRichard Kouitat Njiwa
Richard Kouitat Njiwa
PBPierre Bravetti
Pierre Bravetti
Modern dental implantology is based on a set of more or less related first-order parameters, such as the implant surface and the intrinsic composition of the material. For decades, implant manufacturers have focused on the research and development of the ideal material combined with an optimal surface finish to ensure the success and durability of their product. However, brands do not always communicate transparently about the nature of the products they market. Thus, this study aims to compare the surface finishes and intrinsic composition of three zirconia implants from three major brands. To do so, cross-sections of the apical part of the implants to be analyzed were made with a micro-cutting machine. Samples of each implant of a 4 to 6 mm thickness were obtained. Each was analyzed by a tactile profilometer and scanning electron microscope (SEM). Compositional measurements were performed by X-ray energy-dispersive spectroscopy (EDS). The findings revealed a significant use of aluminum as a chemical substitute by manufacturers. In addition, some manufacturers do not mention the presence of this element in their implants. However, by addressing these issues and striving to improve transparency and safety standards, manufacturers have the opportunity to provide even more reliable products to patients.

6 September 2019 in International Journal of Computational Methods
Verified
Journal Article
Closed access
RNRichard Kouitat Njiwa
Richard Kouitat Njiwa
GPGael Pierson
Gael Pierson
AVArnaud Voignier
Arnaud Voignier