Miguel A. Palacios

Dr. Miguel A. Palacios


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
TFTobias Finazzi
Tobias Finazzi
JKJohn R. van Sörnsen de Koste
John R. van Sörnsen de Koste
MPMiguel A. Palacios
Miguel A. Palacios
FSFemke O.B. Spoelstra
Femke O.B. Spoelstra
BSBerend J. Slotman
Berend J. Slotman
SSSuresh Senan
Suresh Senan
Single-fraction stereotactic ablative radiotherapy (SABR) is an effective treatment for early-stage lung cancer, but concerns remain about the accurate delivery of SABR in a single session. We evaluated the delivery of single-fraction lung SABR using magnetic resonance (MR)-guidance. An MR-simulation was performed in 17 patients, seven of whom were found to be unsuitable, largely due to unreliable tracking of small tumors. Ten patients underwent single-fraction SABR to 34 Gy on a 0.35 T MR-linac system, with online plan adaptation. Gated breath-hold SABR was delivered using a planning target volume (PTV) margin of 5 mm, and a 3 mm gating window. Continuous MR-tracking of the gross tumor volume (GTVt) was performed in sagittal plane, with visual patient feedback provided using an in-room monitor. The real-time MR images were analyzed to determine precision and efficiency of gated delivery. All but one patient completed treatment in a single session. The median total in-room procedure was 120 min, with a median SABR delivery session of 39 min. Review of 7.4 h of cine-MR imaging revealed a mean GTVt coverage by the PTV during beam-on of 99.6%. Breath-hold patterns were variable, resulting in a mean duty cycle efficiency of 51%, but GTVt coverage was not influenced due to real-time MR-guidance. On-table adaptation improved PTV coverage, but had limited impact on GTV doses. Single-fraction gated SABR of lung tumors can be performed with high precision using MR-guidance. However, improvements are needed to ensure MR-tracking of small tumors, and to reduce treatment times.

25 September 2020 in Cancers
Verified
Journal Article
Open access
PDF file
STShyama Tetar
Shyama Tetar
OBOmar Bohoudi
Omar Bohoudi
SSSuresh Senan
Suresh Senan
MPMiguel A. Palacios
Miguel A. Palacios
SOSwie S. Oei
Swie S. Oei
ABAnna Bruynzeel
Anna Bruynzeel
Novel magnetic-resonance-guided radiotherapy (MRgRT) permits real-time soft-tissue visualization, respiratory-gated delivery with minimal safety margins, and time-consuming daily plan re-optimisation. We report on early clinical outcomes of MRgRT and routine plan re-optimization for large primary renal cell cancer (RCC). Thirty-six patients were treated with MRgRT in 40 Gy/5 fractions. Prior to each fraction, re-contouring of tumor and normal organs on a pretreatment MR-scan allowed daily plan re-optimization. Treatment-induced toxicity and radiological responses were scored, which was followed by an offline analysis to evaluate the need for such daily re-optimization in 180 fractions. Mean age and tumor diameter were 78.1 years and 5.6 cm, respectively. All patients completed MRgRT with an average fraction duration of 45 min. Local control (LC) and overall survival rates at one year were 95.2% and 91.2%. No grade ≥3 toxicity was reported. Plans without re-optimization met institutional radiotherapy constraints in 83.9% of 180 fractions. Thus, daily plan re-optimization was required for only a minority of patients, who can be identified upfront by a higher volume of normal organs receiving 25 Gy in baseline plans. In conclusion, stereotactic MRgRT for large primary RCC showed low toxicity and high LC, while daily plan re-optimization was required only in a minority of patients.

9 May 2023 in BMC Cancer
Verified
Journal Article
Open access
PDF file
YCYasmin A. Civil
Yasmin A. Civil
Arlene L. OeiArlene L. Oei
Arlene L. Oei
KDKatya M. Duvivier
Katya M. Duvivier
NBNina Bijker
Nina Bijker
PMPhilip Meijnen
Philip Meijnen
HBH. J. G. Desiree Van Den Bongard
H. J. G. Desiree Van Den Bongard
Background: Partial breast irradiation (PBI) is standard of care in low-risk breast cancer patients after breast-conserving surgery (BCS). Pre-operative PBI can result in tumor downstaging and more precise target definition possibly resulting in less treatment-related toxicity. This study aims to assess the pathologic complete response (pCR) rate one year after MR-guided single-dose pre-operative PBI in low-risk breast cancer patients. Methods: The ABLATIVE-2 trial is a multicenter prospective single-arm trial using single-dose ablative PBI in low-risk breast cancer patients. Patients ≥ 50 years with non-lobular invasive breast cancer ≤ 2 cm, grade 1 or 2, estrogen receptor-positive, HER2-negative, and tumor-negative sentinel node procedure are eligible. A total of 100 patients will be enrolled. PBI treatment planning will be performed using a radiotherapy planning CT and -MRI in treatment position. The treatment delivery will take place on a conventional or MR-guided linear accelerator. The prescribed radiotherapy dose is a single dose of 20 Gy to the tumor, and 15 Gy to the 2 cm of breast tissue surrounding the tumor. Follow-up MRIs, scheduled at baseline, 2 weeks, 3, 6, 9, and 12 months after PBI, are combined with liquid biopsies to identify biomarkers for pCR prediction. BCS will be performed 12 months after radiotherapy or after 6 months, if MRI does not show a radiologic complete response. The primary endpoint is the pCR rate after PBI. Secondary endpoints are radiologic response, toxicity, quality of life, cosmetic outcome, patient distress, oncological outcomes, and the evaluation of biomarkers in liquid biopsies and tumor tissue. Patients will be followed up to 10 years after radiation therapy. Discussion: This trial will investigate the pathological tumor response after pre-operative single-dose PBI after 12 months in patients with low-risk breast cancer. In comparison with previous trial outcomes, a longer interval between PBI and BCS of 12 months is expected to increase the pCR rate of 42% after 6–8 months. In addition, response monitoring using MRI and biomarkers will help to predict pCR. Accurate pCR prediction will allow omission of surgery in future patients. Trial registration: The trial was registered prospectively on April 28th 2022 at clinicaltrials.gov (NCT05350722).

24 February 2022 in Radiotherapy and Oncology
Verified
Journal Article
Open access
CVClaire van Vliet
Claire van Vliet
CDChris Dickhoff
Chris Dickhoff
IBIdris Bahce
Idris Bahce
AEAnton F. Engelsman
Anton F. Engelsman
SHSayed Hashemi
Sayed Hashemi
FSFamke L. Schneiders
Famke L. Schneiders
We studied treatment patterns for adrenal metastases using surgery or SABR at a single institution during a 10-year period. The number of patients undergoing SABR doubled since 2016, without a change in numbers undergoing surgery. Both treatments resulted in low rates of acute toxicity and similar survivals.

4 April 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
MPMiguel A. Palacios
Miguel A. Palacios
GGGeorgi Gerganov
Georgi Gerganov
PCPaul Cobussen
Paul Cobussen
STShyama U. Tetar
Shyama U. Tetar
TFTobias Finazzi
Tobias Finazzi
IKIwan Kawrakow
Iwan Kawrakow
Intra-fraction motion management is key in Stereotactic Ablative Radiotherapy (SABR) gated delivery. This study assessed the accuracy of automatic tumor segmentation in the delivery of MR-guided radiotherapy (MRgRT) by comparing it to manual delineations performed by experienced observers. Twenty patients previously treated with MR-guided SABR for thoracic and abdominal tumors were included. Five observers with at least two years of experience in MRgRT manually delineated the gross tumor volume (GTV) for 20 patients on 240 frames of a cine MRI on a sagittal plane. Deformable Image Registration (DIR) based GTV contours were propagated using four different algorithms from a reference frame to subsequent frames. Geometrical analysis based on the Dice Similarity Coefficient (DSC), centroid distance and Hausdorff Distance (HDD) were performed to assess the inter-observer variability and the accuracy of automatic segmentation. A Confidence Value (CV) metric for the reliability of the tumor auto-contouring was also calculated. Inter-observer delineation variability resulted in mean DSC of 0.89, HDD of 5.8 mm and centroid distance of 1.7 mm. Tumor auto-contouring by the four DIR algorithms resulted in an excellent agreement with the manual delineations by the experienced observers. Mean DSC for each algorithm across all patients was greater than 0.90, whereas the HDD and centroid distances were below 4.0 mm and 1.5 mm, respectively. The CV showed a strong correlation with the DSC. DIR-based auto-contouring in MRgRT exhibited a high level of agreement with the manual contouring performed by experts, allowing accurate gated delivery.

1 November 2020 in Radiotherapy and Oncology
Verified
Journal Article
Open access
JKJohn R. van Sörnsen de Koste
John R. van Sörnsen de Koste
MPMiguel A. Palacios
Miguel A. Palacios
HCHanbo Chen
Hanbo Chen
FSFamke L. Schneiders
Famke L. Schneiders
ABAnna Bruynzeel
Anna Bruynzeel
SSSuresh Senan
Suresh Senan
Delivery of breath-hold MR-guided SABR is time-consuming, and the use of real-time tumor-tracking in a sagittal plane may fail to detect out-of-plane displacements of organs-at-risk. Analysis of daily MR-scans performed pre- and post-SABR revealed frequent decreases in stomach volumes, and in the planned stomach doses.