Introduction: Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator‐ and center‐dependent. This study sought to evaluate a novel machine learning software algorithm named VX1 (Volta Medical), trained to adjudicate multipolar electrogram dispersion.Methods: This study was a prospective, multicentric, nonrandomized study conducted to assess the feasibility of generating VX1 dispersion maps. In 85 patients, 8 centers, and 17 operators, we compared the acute and long‐term outcomes after ablation in regions exhibiting dispersion between primary and satellite centers. We also compared outcomes to a control group in which dispersion‐guided ablation was performed visually by trained operators.Results: The study population included 29% of long‐standing persistent AF. AF termination occurred in 92% and 83% of the patients in primary and satellite centers, respectively, p = 0.31. The average rate of freedom from documented AF, with or without antiarrhythmic drugs (AADs), was 86% after a single procedure, and 89% after an average of 1.3 procedures per patient (p = 0.4). The rate of freedom from any documented atrial arrhythmia, with or without AADs, was 54% and 73% after a single or an average of 1.3 procedures per patient, respectively (p < 0.001). No statistically significant differences between outcomes of the primary versus satellite centers were observed for one (p = 0.8) or multiple procedures (p = 0.4), or between outcomes of the entire study population versus the control group (p > 0.2). Interestingly, intraprocedural AF termination and type of recurrent arrhythmia (i.e., AF vs. AT) appear to be predictors of the subsequent clinical course.Conclusion: VX1, an expertise‐based artificial intelligence software solution, allowed for robust center‐to‐center standardization of acute and long‐term ablation outcomes after electrogram‐based ablation.
9 June 2011 in Pacing and Clinical Electrophysiology
Introduction: During atrial fibrillation (AF) ablation, it is generally considered that atrial tachycardia (AT) episodes are a consequence of ablation. Objective: To investigate the spatial relationship between localized AT episodes and dispersion/ablation regions during persistent AF ablation procedures. Methods: We analyzed 72 consecutive patients who presented for an index persistent AF ablation procedure guided by the presence of spatiotemporal dispersion of multipolar electrograms. We characterized spontaneous or post-ablation ATs’ mechanism and location in regard to dispersion regions and ablation lesions. Results: In 72 consecutive patients admitted for persistent AF ablation, 128 ATs occurred in 62 patients (1.9 ± 1.1/patient). Seventeen ATs were recorded before any ablation. In a total of 100 ATs with elucidated mechanism, there were 58 localized sources and 42 macro-reentries. A large number of localized ATs arose from regions exhibiting dispersion during AF (n = 49, 84%). Importantly, these ATs’ locations were generally remote from the closest ablation lesion (n = 42, 72%). Conclusions: In patients undergoing a persistent AF ablation procedure guided by the presence of spatiotemporal dispersion of multipolar electrograms, localized ATs originate within dispersion regions but remotely from the closest ablation lesion. These results suggest that ATs represent a stabilized manifestation of co-existing AF drivers rather than ablation-induced arrhythmias.
Aims: There is still conflicting evidence if women with persistent atrial fibrillation (AF) profit from a pulmonary vein isolation (PVI) plus strategy. We evaluated the efficacy of a spatio-temporal dispersion-targeted ablation strategy in women from the TAILORED-AF trial. Methods and results: In TAILORED-AF, 370 patients were randomised to either a personalised, artificial intelligence (AI)-guided tailored ablation or to PVI-only. AF substrate mapping data and 12-month ablation outcomes were compared between women and men. Overall, 21% patients were female (70.4 ± 6.9 vs. 64.5 ± 8.5 years for men, P < 0.001). While spatio-temporal dispersion extent was similar between groups, left atrial low-voltage surface area (<0.2 mV) was significantly larger in women (P < 0.01). In women, the single-procedure freedom from AF (76% vs. 50%, log-rank P < 0.001) and any atrial arrhythmia (56% vs. 38%, log-rank P < 0.05) were significantly superior to PVI alone with a tailored procedure. In the PVI-only group, the single-procedure freedom from AF (50% vs. 70%, log-rank P < 0.001) and any atrial arrhythmia (38% vs. 61%, log-rank P < 0.001) were significantly lower in women. After a tailored ablation, no significant differences were observed between women and men regarding freedom from AF (76% vs. 91%, log-rank P = 0.07) or any atrial arrhythmia (56% vs. 62%, log-rank P = 0.69) free survival. Conclusion: Compared to men, PVI-only in women with persistent AF leads to a significantly lower freedom from atrial arrhythmia. A personalised spatio-temporal dispersion-targeted ablation strategy led to a higher rate of freedom from any atrial arrhythmia than standard PVI after a single procedure in women and comparable outcomes between women and men. Registration identification: clinicaltrials.gov NCT04702451