Hatem Alkadhi

Prof. Dr. Hatem Alkadhi

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2006 in European Radiology
Verified
Journal Article
Open access
PDF file
HSHans Scheffel
Hans Scheffel
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
APAndré Plass
André Plass
RVRobert Vachenauer
Robert Vachenauer
LDLotus Desbiolles
Lotus Desbiolles
SLSebastian Leschka
Sebastian Leschka
The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9 kg/m2 (range 22.4–36.3 kg/m2), mean heart rate during CT was 70.3±14.2 bpm (range 47–102 bpm), and mean Agatston score was 821±904 (range 0–3,110). Image quality was diagnostic (scores 1–3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

1 November 2006 in Radiology
Verified
Journal Article
Closed access
SLSebastian Leschka
Sebastian Leschka
SWSimon Wildermuth
Simon Wildermuth
TBThomas Boehm
Thomas Boehm
LDLotus Desbiolles
Lotus Desbiolles
LHLars Husmann
Lars Husmann
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Purpose: To evaluate prospectively the effect of average heart rate and heart rate variability on image quality at 64-section computed tomographic (CT) coronary angiography. Materials and Methods: The study protocol had local ethics committee approval; written informed consent was obtained. There were 125 patients (45 women, 80 men; mean age, 59.9 years ± 12.9 [standard deviation]; 79 receiving β-blockers) who underwent 64-section CT coronary angiography with retrospective electrocardiographic gating. Data sets were reconstructed in 5% steps from 20% to 80% of R-R interval. Heart rate variability was calculated as 1 standard deviation from mean rate during scanning. Two observers rated image quality of each coronary segment at least 1.5-mm diameter (1 = no motion artifacts, 5 = not evaluative). Repeated analysis of variance measurements were performed to evaluate quantitative parameters. Pearson correlation analysis was performed to compare image quality in each patient with average heart rate and heart r...

8 April 2008 in European Radiology
Verified
Journal Article
Closed access
PDF file
SLSebastian Leschka
Sebastian Leschka
PSPaul Stolzmann
Paul Stolzmann
FSFlorian T. Schmid
Florian T. Schmid
HSHans Scheffel
Hans Scheffel
BSBjoern Stinn
Bjoern Stinn
SWSimon Wildermuth
Simon Wildermuth

6 August 2011 in European Radiology
Verified
Journal Article
Closed access
PDF file
AWAnna Winklehner
Anna Winklehner
CKChristoph Karlo
Christoph Karlo
GPGilbert Puippe
Gilbert Puippe
BSBernhard Schmidt
Bernhard Schmidt
TFThomas Flohr
Thomas Flohr
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi

31 May 2022 in Investigative Radiology
Verified
Journal Article
Open access
VMVictor Mergen
Victor Mergen
TSThomas Sartoretti
Thomas Sartoretti
MBMatthias Baer-Beck
Matthias Baer-Beck
BSBernhard Schmidt
Bernhard Schmidt
MPMartin Petersilka
Martin Petersilka
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Objectives: The aim of this study was to evaluate the feasibility and quality of ultra-high-resolution coronary computed tomography angiography (CCTA) with dual-source photon-counting detector CT (PCD-CT) in patients with a high coronary calcium load, including an analysis of the optimal reconstruction kernel and matrix size. Materials and Methods: In this institutional review board–approved study, 20 patients (6 women; mean age, 79 ± 10 years; mean body mass index, 25.6 ± 4.3 kg/m2) undergoing PCD-CCTA in the ultra-high-resolution mode were included. Ultra-high-resolution CCTA was acquired in an electrocardiography-gated dual-source spiral mode at a tube voltage of 120 kV and collimation of 120 × 0.2 mm. The field of view (FOV) and matrix sizes were adjusted to the resolution properties of the individual reconstruction kernels using a FOV of 200 × 200 mm2 or 150 × 150 mm2 and a matrix size of 512 × 512 pixels or 1024 × 1024 pixels, respectively. Images were reconstructed using vascular kernels of 8 sharpness levels (Bv40, Bv44, Bv56, Bv60, Bv64, Bv72, Bv80, and Bv89), using quantum iterative reconstruction (QIR) at a strength level of 4, and a slice thickness of 0.2 mm. Images with the Bv40 kernel, QIR at a strength level of 4, and a slice thickness of 0.6 mm served as the reference. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and blooming artifacts were quantified. For subjective image quality, 2 blinded readers evaluated image noise and delineation of coronary artery plaques and the adjacent vessel lumen using a 5-point discrete visual scale. A phantom scan served to characterize image noise texture by calculating the noise power spectrum for every reconstruction kernel. Results: Maximum spatial frequency (fpeak) gradually shifted to higher values for reconstructions with the Bv40 to Bv64 kernel (0.15 to 0.56 mm−1), but not for reconstructions with the Bv72 to Bv89 kernel. Ultra-high-resolution CCTA was feasible in all patients (median calcium score, 479). In patients, reconstructions with the Bv40 kernel and a slice thickness of 0.6 mm showed largest blooming artifacts (55.2% ± 9.8%) and lowest vessel sharpness (477.1 ± 73.6 ΔHU/mm) while achieving highest SNR (27.4 ± 5.6) and CNR (32.9 ± 6.6) and lowest noise (17.1 ± 2.2 HU). Considering reconstructions with a slice thickness of 0.2 mm, image noise, SNR, CNR, vessel sharpness, and blooming artifacts significantly differed across kernels (all P's < 0.001). With higher kernel sharpness, SNR and CNR continuously decreased, whereas image noise and vessel sharpness increased, with highest sharpness for the Bv89 kernel (2383.4 ± 787.1 ΔHU/mm). Blooming artifacts continuously decreased for reconstructions with the Bv40 (slice thickness, 0.2 mm; 52.8% ± 9.2%) to the Bv72 kernel (39.7% ± 9.1%). Subjective noise was perceived by both readers in agreement with the objective measurements. Considering delineation of coronary artery plaques and the adjacent vessel lumen, reconstructions with the Bv64 and Bv72 kernel (for both, median score of 5) were favored by the readers providing an excellent anatomic delineation of plaque characteristics and vessel lumen. Conclusions: Ultra-high-resolution CCTA with PCD-CT is feasible and enables the visualization of calcified coronaries with an excellent image quality, high sharpness, and reduced blooming. Coronary plaque characterization and delineation of the adjacent vessel lumen are possible with an optimal quality using Bv64 kernel, a FOV of 200 × 200 mm2, and a matrix size of 512 × 512 pixels.

1 November 2007 in Radiology
Verified
Journal Article
Closed access
LHLars Husmann
Lars Husmann
SLSebastian Leschka
Sebastian Leschka
LDLotus Desbiolles
Lotus Desbiolles
TSTiziano Schepis
Tiziano Schepis
OGOliver Gaemperli
Oliver Gaemperli
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
This study had institutional review board approval; written informed consent was obtained. The purpose was to prospectively determine the heart rate (HR) dependency of three-dimensional (3D) coronary artery motion by incorporating into analysis the durations of systole and diastole. Thirty patients (seven women, 23 men; mean age, 56.6 years ± 12.7 [standard deviation]; HR: 45–100 beats per minute) underwent electrocardiographically gated 64-section computed tomographic (CT) coronary angiography to determine coronary motion velocities at bifurcation points. Significance of velocity differences (P < .05) was determined by using analysis of variance for repeated measures and Bonferroni post hoc tests. HR dependency was determined by using linear regression analysis. HR significantly affected 3D coronary motion (r = 0.47, P < .009) through nonproportional shortening of systole and diastole (r = −0.82, P < .001), leading to percentage reconstruction interval shifts of coronary velocity troughs and peaks (P < ....