This paper describes the experimental results of testing a prototype of a high precision human skin rapid temperature fluctuations measuring instrument. Based on the author’s work, an original circuit solution on a miniature semiconductor diode sensor has been designed. The proposed circuitry provides operation in the full voltage range with automatic setting and holding the operating point, as well as the necessary slope of the conversion coefficient (up to 2300 mV/°C), which makes it possible to register fast temperature oscillations from the surface of the human body and other biological objects. Simulation results in the Microcap 12 software and laboratory tests have confirmed all declared design specifications: temperature resolution of 0.01 °C, transducer thermal time constant of 0.05 s. An original thermostat and an experimental setup for the simultaneous registration of the electrocardiogram, pulse wave signals from the Biopac polygraph MP36 and a signal of temperature oscillations from the prototype thermometer have been designed for further investigations. The preliminary test results indicates that using the designed measuring instrument gives a possibility to provide an in-depth study of the relationship between micro- and macro-blood circulations manifested in skin temperature fluctuations.
Complex postural loads have a significant effect on all systems of the human body. Such movements in space create unique conditions for the correction of his hemodynamics. Special technical means are required to ensure reliable registration of physiological parameters. The aim of the work was the development of such a multi-channel device with high accuracy of analog to digital signal conversion and wireless data transmission. To develop the device, methods of automatic control and digital signal processing were used. Schemes of adaptive amplification of signals with automatic choice of a working point have been developed. The device is implemented on the basis of a modern electronic base using fast ADCs (1000 kbps), microcontrollers (32 bits) and Bluetooth modules (4th generation). The tests that confirmed the declared characteristics were carried out. Also, the developed device was used in a complex study of the neuro-systemic reactions of the human body to complex postural loads.
1 April 2020 in Journal of Physics: Conference Series
The developed device refers to analog low-pass filtering circuits and works as Butterworth-type broadband active RC filter. This filter can be used in devices for the human cardiovascular system diagnostic purposes, providing an opportunity to assess the state of the cardiovascular system. Such approach is based on the analysis of cardiointervalogram spectral power and can be implemented in biofeedback systems that use the current values of this power to generate feedback signals. The filter consists of second-order active bandpass filter blocks, connected together in series. Implemented schematic provides simultaneous tuning of the resonant frequency and the quality factor of the band-pass filter. This feature allowing to adjust the bandwidth while maintaining the center frequency and tuning the center frequency while maintaining the constancy of the band. The selection of bandpass filter tuning mode is made by selecting the appropriate adjustable components.
This paper presents modification of algorithm for the estimation of arterial blood pressure by the pulse wave propagation time. The work of the previously developed algorithm for evaluation of human blood pressure by pulse wave propagation time and the problem of its further optimization, based on the analysis of data for fifteen series of measurements of synchronously recorded electrocardiogram and pulse wave signals in twenty healthy subjects, was considered. The hypothesis about influence of heart rate variability on error of algorithm for blood pressure estimation by pulse wave propagation time was verified. As the result of this investigation, in order to increase the efficiency of the algorithm for arterial pressure indirect estimation, while calculating correction factors, it is necessary to use not only the current values of the heart rate, but also the average values. This requires preliminary registration of electrocardiogram signal for rather long time and using complex algorithms for signal processing.
Objective. To assess the impact of COVID-19 and anti-epidemic restrictions during the pandemic on the health quality and lifestyle of technical universities’ students of Saint Petersburg. Material and methods. A cohort study was conducted in a representative sample of mainly undergraduate students of Saint-Petersburg’s technical universities from 2018 to 2023 yrs. Of the 234 participants, 44% (102) of whom were boys and 56% (132) were girls. All the sample members included in the study filled in the lifestyle and health condition questionnaires after the exclusion criteria were applied. A physician examined the students and measured their individual indicators. Results. The lifestyle and health status of students of Saint-Petersburg’s technical universities in the period before and after the lockdown introduced due to the spread of a new coronavirus infection, in comparison with equivalent data obtained in similar studies on the territory of Russia and in other countries, have been characterized. Changes in the lifestyle of students (including day regimen, time of electronic devices use, interest in sports, bad habits), changes in their anthropometric indicators, as well as functional indicators and tests have been analyzed. The obtained original results of the respiratory tests showed a change of hypoxia sensitivity in persons who had suffered from coronavirus infection. Conclusion. Multidirectional changes of indicators describing the lifestyle and health quality of students in the early and late post-lockdown periods were demonstrated. Further analysis of the indicators in terms of stress and adaptation theory is needed.