Uwe Hampel

Dr. Uwe Hampel

Helmholtz-Zentrum Dresden-Rossendorf, Head Experimental Thermal Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden, Germany
+1
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2007 in Measurement Science and Technology
Verified
Journal Article
Closed access
MSM J Da Silva
M J Da Silva
ESE Schleicher
E Schleicher
UHUwe Hampel
Uwe Hampel

1 September 2010 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
MSM.J. Da Silva
M.J. Da Silva
STS. Thiele
S. Thiele
LAL. Abdulkareem
L. Abdulkareem
BAB.J. Azzopardi
B.J. Azzopardi
UHUwe Hampel
Uwe Hampel

24 July 2008 in Measurement Science and Technology
Verified
Journal Article
Closed access
FFF Fischer
F Fischer
DHD Hoppe
D Hoppe
ESE Schleicher
E Schleicher
GMG Mattausch
G Mattausch
HFH Flaske
H Flaske
UHUwe Hampel
Uwe Hampel

1 June 2010 in Chemical Engineering Science
Verified
Journal Article
Closed access
LSL. Szalinski
L. Szalinski
LAL.A. Abdulkareem
L.A. Abdulkareem
MSM.J. Da Silva
M.J. Da Silva
STS. Thiele
S. Thiele
MBM. Beyer
M. Beyer
BAB.J. Azzopardi
B.J. Azzopardi

1 September 2010 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
FFF. Fischer
F. Fischer
UHUwe Hampel
Uwe Hampel

1 October 2007 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
UHUwe Hampel
Uwe Hampel
ABA. Bieberle
A. Bieberle
DHD. Hoppe
D. Hoppe
JKJ. Kronenberg
J. Kronenberg
ESE. Schleicher
E. Schleicher
CZC. Zippe
C. Zippe
We report on the development of a high resolution gamma ray tomography scanner that is operated with a Cs-137 isotopic source at 662keV gamma photon energy and achieves a spatial image resolution of 0.2linepairs∕mm at 10% modulation transfer function for noncollimated detectors. It is primarily intended for the scientific study of flow regimes and phase fraction distributions in fuel element assemblies, chemical reactors, pipelines, and hydrodynamic machines. Furthermore, it is applicable to nondestructive testing of larger radiologically dense objects. The radiation detector is based on advanced avalanche photodiode technology in conjunction with lutetium yttrium orthosilicate scintillation crystals. The detector arc comprises 320 single detector elements which are operated in pulse counting mode. For measurements at fixed vessels or plant components, we built a computed tomography scanner gantry that comprises rotational and translational stages, power supply via slip rings, and data communication to the measurement personal computer via wireless local area network.