Tadas Zdankus

Prof. Tadas Zdankus

Kaunas University of Technology
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Paris FokaidesParis Fokaides
Paris Fokaides
Rasa ApanavičienėRasa Apanavičienė
Rasa Apanavičienė
JCJurgita Cerneckiene
Jurgita Cerneckiene
AJAndrius Jurelionis
Andrius Jurelionis
Egle KlumbyteEgle Klumbyte
Egle Klumbyte
Tadas ZdankusTadas Zdankus
Tadas Zdankus
Inevitably, the 21st century has initiated a series of developments in the construction industry, leading to its digitalization and resulting in a series of innovative approaches and practices. At the same time, the construction industry, being one of the main global environment polluters, should fulfil well-established, as well as novel, sustainability requirements in order to evolve in harmony with the rising concerns on the availability of natural resources. This overview study aims to present the main developments, research, and scientific challenges in the field of sustainable construction, emphasizing the field of energy. The study aims to present a state-of-the-art scientific discussion on the sustainable built environment topic by analyzing cutting edge topics in the fields of building elements and whole building energy assessment, of indoor air quality and low carbon buildings, as well as on sustainable energy systems and smart buildings. The study also presents the state-of-the-art in existing tools which are adopted for the assessment of the sustainable built environment, including the use of digital tools and building information modelling for the energy assessment of the built environment, as well as the application of Life Cycle Assessment on building-related processes. Cross cutting issues related to the analysis of the building sector in the Industry 4.0 era, such as sustainability management topics and environmental geomatics are also discussed. The study concludes in those fields which will be of interest of the scientific community in the following years, towards achieving the goals of the sustainable development of the building sector.

1 February 2014 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
JGJ. Gylys
J. Gylys
Tadas ZdankusTadas Zdankus
Tadas Zdankus
MGM. Gylys
M. Gylys

12 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
Lina SeduikyteLina Seduikyte
Lina Seduikyte
LSLaura Stasiuliene
Laura Stasiuliene
TPTadas Prasauskas
Tadas Prasauskas
DMDainius Martuzevičius
Dainius Martuzevičius
JCJurgita Cerneckiene
Jurgita Cerneckiene
Paris FokaidesParis Fokaides
Paris Fokaides
Sports halls must meet strict requirements for energy and indoor air quality (IAQ); therefore, there is a great challenge in the design of the heating, ventilation, and air conditioning (HVAC) systems of such buildings. IAQ in sports halls may be affected by thermal stratification, pollutants from different sources, the maintenance of building, and the HVAC system of the building, as well as by the activities performed inside the building. The aim of this study is to investigate thermal stratification conditions in accordance with the performance of the HVAC systems in the basketball training hall of Žalgirio Arena, Kaunas in Lithuania. Field measurements including temperature, relative humidity, and CO2 concentration were implemented between January and February in 2017. The temperature and relative humidity were measured at different heights (0.1, 1.7, 2.5, 3.9, 5.4, and 6.9 m) and at five different locations in the arena. Experimental results show that mixing the ventilation application together with air heating results in higher temperatures in the occupied zone than in the case of air heating without ventilation. Computational fluid dynamics (CFD) simulations revealed that using the same heating output as for warm air heating and underfloor heating, combined with mechanical mixing or displacement ventilation, ensures higher temperatures in the occupied zone, creating a potential for energy saving. An increase of air temperature was noticed from 3.9 m upwards. Since CO2 concentration near the ceiling was permissible, the study concluded that it is possible to recycle the air from the mentioned zone and use it again by mixing with the air of lower layers, thus saving energy for air heating.

1 October 2014 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
NZNarimantas Zdankus
Narimantas Zdankus
PPPetras Punys
Petras Punys
Tadas ZdankusTadas Zdankus
Tadas Zdankus

31 January 2008 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
JGJ. Gylys
J. Gylys
SSS. Sinkunas
S. Sinkunas
Tadas ZdankusTadas Zdankus
Tadas Zdankus

30 April 2013 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
JGJ. Gylys
J. Gylys
Tadas ZdankusTadas Zdankus
Tadas Zdankus
MGM. Gylys
M. Gylys