Wendy Goodwin

Dr. Wendy Goodwin

School of Veterinary Science, University of Queensland, Queensland 4343, Australia
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
PDF file
WGWendy Goodwin
Wendy Goodwin
HKHelen L Keates
Helen L Keates
KPKirby Pasloske
Kirby Pasloske
MPMartin Pearson
Martin Pearson
BSBen Sauer
Ben Sauer
MRMillaganamada Gedara Ranasinghe
Millaganamada Gedara Ranasinghe

1 September 2012 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
PDF file
WGWendy Goodwin
Wendy Goodwin
HKHelen Keates
Helen Keates
KPKirby Pasloske
Kirby Pasloske
MPMartin Pearson
Martin Pearson
BSBen Sauer
Ben Sauer
MRMillagahamada G Ranasinghe
Millagahamada G Ranasinghe

12 April 2024 in European Spine Journal
Verified
Journal Article
Open access
PDF file
GJGregory James
Gregory James
BABen Ahern
Ben Ahern
WGWendy Goodwin
Wendy Goodwin
BGB. Goss
B. Goss
PHPaul Hodges
Paul Hodges
Purpose: Aerobic exercise produces beneficial outcomes in patients with low back pain and partially attenuates the fibrotic changes to the multifidus in a model of intervertebral disc (IVD) degeneration. More targeted exercise might be required to fully attenuate these fibrotic alterations. This study aimed to investigate whether activation of the multifidus induced by neurostimulation could reduce fibrosis of the multifidus in a model of IVD degeneration in sheep. Methods: IVD degeneration was induced in 18 merino sheep via a partial thickness unilateral annulus fibrosus lesion to the L1/2 and L3/4 IVDs. All sheep received an implantable neurostimulation device that provides stimulation of the L2 medial branch of the dorsal ramus. Three months after surgery, the animals were assigned to Injury or Activated groups. Activated animals received neurostimulation and the Injury group received no stimulation. Six months after surgery, the multifidus was harvested at L2 and L4. Van Gieson’s, Sirius Red and immunofluorescence staining for Collagen-I and -III and quantitative PCR was used to examine fibrosis. Muscle harvested from a previous study without IVD injury was used as a control. Results: Neurostimulation of the multifidus attenuated IVD degeneration dependent increases in the connective tissue, including Collagen-I but not Collagen-III, compared to the Injury group at L4. No measures of the multifidus muscle at L2, which received no stimulation, differed between the Injury and Activated groups. Conclusions: These data reveal that targeted activation of the multifidus muscle attenuates IVD degeneration dependent fibrotic alterations to the multifidus.

8 August 2012 in Equine Veterinary Journal
Verified
Journal Article
Closed access
PDF file
WGWendy Goodwin
Wendy Goodwin
HKH. L. Keates
H. L. Keates
MPM. Pearson
M. Pearson
KPK. Pasloske
K. Pasloske

7 September 2020 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
JDJayesh Dhanani
Jayesh Dhanani
GPGeorge Pang
George Pang
JPJason Pincus
Jason Pincus
BABen Ahern
Ben Ahern
WGWendy Goodwin
Wendy Goodwin
FEFelicity Edwards
Felicity Edwards
Objective: The advent of new technologies has made it possible to explore alternative ventilator manufacturing to meet the worldwide shortfall for mechanical ventilators especially in pandemics. We describe a method using rapid prototyping technologies to create an electro-mechanical ventilator in a cost effective, timely manner and provide results of testing using an in vitro–in vivo testing model. Results: Rapid prototyping technologies (3D printing and 2D cutting) were used to create a modular ventilator. The artificial manual breathing unit (AMBU) bag connected to wall oxygen source using a flow meter was used as air reservoir. Controlled variables include respiratory rate, tidal volume and inspiratory: expiratory (I:E) ratio. In vitro testing and In vivo testing in the pig model demonstrated comparable mechanical efficiency of the test ventilator to that of standard ventilator but showed the material limits of 3D printed gears. Improved gear design resulted in better ventilator durability whilst reducing manufacturing time (< 2-h). The entire cost of manufacture of ventilator was estimated at 300 Australian dollars. A cost-effective novel rapid prototyped ventilator for use in patients with respiratory failure was developed in < 2-h and was effective in anesthetized, healthy pig model.

1 March 2019 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
WGWendy Goodwin
Wendy Goodwin
KPKirby Pasloske
Kirby Pasloske
HKHelen L. Keates
Helen L. Keates
MRMillaganamada Gedara Ranasinghe
Millaganamada Gedara Ranasinghe
SWSolomon Woldeyohannes
Solomon Woldeyohannes
NPNigel Perkins
Nigel Perkins