Gaoliang Dai

Dr. Gaoliang Dai


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2004 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GDGaoliang Dai
Gaoliang Dai
FPFrank Pohlenz
Frank Pohlenz
HDHans-Ulrich Danzebrink
Hans-Ulrich Danzebrink
MXMin Xu
Min Xu
KHKlaus Hasche
Klaus Hasche
GWGuenter Wilkening
Guenter Wilkening
We describe a metrological large range scanning probe microscope (LR-SPM) with an Abbe error free design and direct interferometric position measurement capability, aimed at versatile traceable topographic measurements that require nanometer accuracy. A dual-stage positioning system was designed to achieve both a large measurement range and a high measurement speed. This dual-stage system consists of a commercially available stage, referred to as nanomeasuring machine (NMM), with a motion range of 25 mm×25 mm×5 mm along x, y, and z axes, and a compact z -axis piezoelectric positioning stage (compact z stage) with an extension range of 2 μm. The metrological LR-SPM described here senses the surface using a stationary fixed scanning force microscope (SFM) head working in contact mode. During operation, lateral scanning of the sample is performed solely by the NMM. Whereas the z motion, controlled by the SFM signal, is carried out by a combination of the NMM and the compact z stage. In this case the compact z stage, with its high mechanical resonance frequency (greater than 20 kHz), is responsible for the rapid motion while the NMM simultaneously makes slower movements over a larger motion range. To reduce the Abbe offset to a minimum the SFM tip is located at the intersection of three interferometer measurement beams orientated in x, y, and z directions. To improve real time performance two high-end digital signal processing (DSP) systems are used for NMM positioning and SFM servocontrol. Comprehensive DSP firmware and Windows XP-based software are implemented, providing a flexible and user-friendly interface. The instrument is able to perform large area imaging or profile scanning directly without stitching small scanned images. Several measurements on different samples such as flatness standards, nanostep height standards, roughness standards as well as sharp nanoedge samples and 1D gratings demonstrate the outstanding metrological capabilities of the instrument.

28 April 2005 in Measurement Science and Technology
Verified
Journal Article
Closed access
GDGaoliang Dai
Gaoliang Dai
LKLudger Koenders
Ludger Koenders
FPFrank Pohlenz
Frank Pohlenz
TDThorsten Dziomba
Thorsten Dziomba
HDHans-Ulrich Danzebrink
Hans-Ulrich Danzebrink

31 January 2006 in Measurement Science and Technology
Verified
Journal Article
Closed access
GDGaoliang Dai
Gaoliang Dai
FPFrank Pohlenz
Frank Pohlenz
MXMin Xu
Min Xu
LKLudger Koenders
Ludger Koenders
HDHans-Ulrich Danzebrink
Hans-Ulrich Danzebrink
GWGünter Wilkening
Günter Wilkening

30 June 2009 in Measurement Science and Technology
Verified
Journal Article
Closed access
GDGaoliang Dai
Gaoliang Dai
SBSebastian Bütefisch
Sebastian Bütefisch
FPFrank Pohlenz
Frank Pohlenz
HDHans-Ulrich Danzebrink
Hans-Ulrich Danzebrink

1 April 2009 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GDGaoliang Dai
Gaoliang Dai
HWHelmut Wolff
Helmut Wolff
FPFrank Pohlenz
Frank Pohlenz
HDHans-Ulrich Danzebrink
Hans-Ulrich Danzebrink
A metrological large range atomic force microscope (Met. LR-AFM) has been set up and improved over the past years at Physikalisch-Technische Bundesanstalt (PTB). Being designed as a scanning sample type instrument, the sample is moved in three dimensions by a mechanical ball bearing stage in combination with a compact z -piezostage. Its topography is detected by a position-stationary AFM head. The sample displacement is measured by three embedded miniature homodyne interferometers in the x , y , and z directions. The AFM head is aligned in such a way that its cantilever tip is positioned on the sample surface at the intersection point of the three interferometer measurement beams for satisfying the Abbe measurement principle. In this paper, further improvements of the Met. LR-AFM are reported. A new AFM head using the beam deflection principle has been developed to reduce the influence of parasitic optical interference phenomena. Furthermore, an off-line Heydemann correction method has been applied to reduce the inherent interferometer nonlinearities to less than 0.3 nm (p-v) . Versatile scanning functions, for example, radial scanning or local AFM measurement functions, have been implemented to optimize the measurement process. The measurement software is also improved and allows comfortable operations of the instrument via graphical user interface or script-based command sets. The improved Met. LR-AFM is capable of measuring, for instance, the step height, lateral pitch, line width, nanoroughness, and other geometrical parameters of nanostructures. Calibration results of a one-dimensional grating and a set of film thickness standards are demonstrated, showing the excellent metrological performance of the instrument.

12 January 2007 in Measurement Science and Technology
Verified
Journal Article
Closed access
GDGaoliang Dai
Gaoliang Dai
FPFrank Pohlenz
Frank Pohlenz
TDThorsten Dziomba
Thorsten Dziomba
MXMin Xu
Min Xu
ADAlexander Diener
Alexander Diener
HDHans-Ulrich Danzebrink
Hans-Ulrich Danzebrink