Chi-Lun Lin

Dr. Chi-Lun Lin

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2013 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
DCDane Coffey
Dane Coffey
CLChi-Lun Lin
Chi-Lun Lin
AEArthur G. Erdman
Arthur G. Erdman
DKDaniel F. Keefe
Daniel F. Keefe
We present an interface for exploring large design spaces as encountered in simulation-based engineering, design of visual effects, and other tasks that require tuning parameters of computationally-intensive simulations and visually evaluating results. The goal is to enable a style of design with simulations that feels as-direct-as-possible so users can concentrate on creative design tasks. The approach integrates forward design via direct manipulation of simulation inputs (e.g., geometric properties, applied forces) in the same visual space with inverse design via 'tugging' and reshaping simulation outputs (e.g., scalar fields from finite element analysis (FEA) or computational fluid dynamics (CFD)). The interface includes algorithms for interpreting the intent of users' drag operations relative to parameterized models, morphing arbitrary scalar fields output from FEA and CFD simulations, and in-place interactive ensemble visualization. The inverse design strategy can be extended to use multi-touch input in combination with an as-rigid-as-possible shape manipulation to support rich visual queries. The potential of this new design approach is confirmed via two applications: medical device engineering of a vacuum-assisted biopsy device and visual effects design using a physically based flame simulation.

16 May 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
YCYung-Chung Chen
Yung-Chung Chen
CLChi-Lun Lin
Chi-Lun Lin
CHChun-Hsien Hou
Chun-Hsien Hou
Background: This study evaluates the mechanical performance of deep margin elevation technique for carious cavities by considering the shape designs and material selections of inlay using a computational approach combined with the design of experiments method. The goal is to understand the effects of the design parameters on the deep margin elevation technique and provide design guidelines from the biomechanics perspective. Methods: Seven geometric design parameters for defining an inlay’s shape of a premolar were specified, and the influence of cavity shape and material selection on the overall stress distribution was investigated via automated modelling. Material selection included composite resin, ceramic, and lithium disilicate. Finite element analysis was performed to evaluate the mechanical behavior of the tooth and inlay under a compressive load. Next, the analysis of variance was conducted to identify the parameters with a significant effect on the stress occurred in the materials. Finally, the response surface method was used to analyze the stress responses of the restored tooth with different design parameters. Results: The restored tooth with a larger isthmus width demonstrated superior mechanical performance in all three types of inlay materials, while the influence of other design parameters varied with the inlay material selection. The height of the deep margin elevation layer insignificantly affected the mechanical performance of the restored tooth. Conclusions: A proper geometric design of inlay enhances the mechanical performance of the restored tooth and could require less volume of the natural dentin to be excavated. Furthermore, under the loading conditions evaluated in this study, the deep margin elevation layer did not extensively affect the strength of the tooth structure.

22 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SNSi Yen Ng
Si Yen Ng
YKYao-Lung Kuo
Yao-Lung Kuo
CLChi-Lun Lin
Chi-Lun Lin
We aimed to develop an inexpensive and easy-to-fabricate gelatin-based training phantom for improving the breast biopsy skill and confidence level of residents. Young’s modulus and acoustic properties of the gelatin tissue phantom and simulated tumors were investigated. Six residents were requested to evaluate the effectiveness of the breast phantom. The results showed that 83% (n = 5) of the participants agreed that the ultrasound image quality produced by the breast phantom was excellent or good. Only 17% (n = 1) of the participants claimed that there was room for improvement for the haptic feedback they received during the placement of the core needle into the breast phantom. The mean pre-instructional score was 17% (SD 17%) for all participants. The mean post-instructional score was 83% (SD 17%), giving an overall improvement of 67%. In conclusion, the mean needle biopsy skill and confidence levels of the participants substantially increased through simulation training on our breast phantom. The participants’ feedback showed the phantom is sufficiently realistic in terms of ultrasound imaging and haptic feedback during needle insertion; thus, the training outcome can be linked to the performance of residents when they perform a live biopsy.

9 March 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CLChi-Lun Lin
Chi-Lun Lin
YHYu-An Huang
Yu-An Huang
Rotational needle insertion is commonly used in needle biopsy to improve cutting performance. The application of rotational motion for needle insertion has been shown to efficiently reduce the cutting force. However, studies have found that needle rotation can increase tissue damage due to the tissue winding effect. The bidirectional rotation of a needle during insertion can be a solution to avoid tissue winding while maintaining a low cutting force. In this study, needle insertion with bidirectional rotation was investigated by conducting mechanical and optical experiments. First, needle insertion tests were performed on gelatin-based tissue phantom samples to understand the effect of bidirectional needle rotation on the cutting force. Subsequently, the effective strain, which is an indicator of tissue damage, was observed at the cross-sections of samples in the axial and radial directions of the needle by using the digital image correlation (DIC) technology. The primary findings of this study are as follows: (1) higher needle insertion speeds result in higher cutting forces and effective strains that occur at the axial cross-section, (2) increase in the needle rotation reduces the cutting force and effective strain at the axial cross-section but increases the effective strain at the radial cross-section, (3) application of bidirectional rotation decreases the mean effective strain at the radial cross-section by 10%-25% while maintaining a low cutting force. In clinical applications, bidirectional rotation can be a useful strategy to simultaneously reduce the cutting force and tissue damage, which leads to better cutting performance and lower risks of bleeding and hematoma.

27 March 2024 in Journal of Dental Sciences
Verified
Journal Article
Open access
YCYung-Chung Chen
Yung-Chung Chen
KWKuan-Hsin Wang
Kuan-Hsin Wang
CLChi-Lun Lin
Chi-Lun Lin
The All-on-4® treatment concept is a dental procedure that utilizes only four dental implants to support a fixed prosthesis, providing full-arch rehabilitation with affordable cost and speedy treatment courses. Although the placement of all-on-4® implants has been researched in the past, little attention was paid to the structural design of the prosthetic framework. This research proposed a new approach to optimize the structure of denture framework called BESO-Net, which is a bidirectional evolutionary structural optimization (BESO) based convolutional neural network (CNN). The approach aimed to reduce the use of material for the framework, such as Ti-6Al-4V, while maintaining structural strength. The BESO-Net was designed as a one-dimensional CNN based on Inception V3, trained using finite element analysis (FEA) data from 14,994 design configurations, and evaluated its training performance, generalization capability, and computation efficiency. The results suggested that BESO-Net accurately predicted the optimal structure of the denture framework in various mandibles with different implant and load settings. The average error was found to be 0.29% for compliance and 11.26% for shape error when compared to the traditional BESO combined with FEA. Additionally, the computational time required for structural optimization was significantly reduced from 6.5 h to 45 s. The proposed approach demonstrates its applicability in clinical settings to quickly find personalized All-on-4® framework structure that can significantly reduce material consumption while maintaining sufficient stiffness.

6 November 2018 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
CLChi-Lun Lin
Chi-Lun Lin
GLGuan-Jhong Lan
Guan-Jhong Lan
The rotational cutting method has been used in needle biopsy technologies to sample tough tissues, such as calcifications in the breast. The rotational motion of the needle introduces shear forces to the cutting surface such that the cutting force in the axial direction is reduced. As a result, tissue samples with large volume and better quality can be obtained. In order to comprehensively understand the effect of the needle rotation to the axial cutting force under a wide range of the needle insertion speed, this paper demonstrates a computational approach that incorporates the surface-based cohesive behavior to simulate a rotating needle cutting soft tissue. The computational model is validated by comparing with a cutting test dataset reported in the literature. The validated model is then used to generate response surfaces of the axial cutting force and torque in a large parameter space of needle rotation and insertion speeds. The results provide guidelines for selecting optimal speed configurations under different design situations.