Pritam Chakraborty

Mr. Pritam Chakraborty

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Cogent Engineering
Verified
Journal Article
Open access
PCPritam Chakraborty
Pritam Chakraborty
BNBiswarup Neogi
Biswarup Neogi
ADAchintya Das
Achintya Das
In this paper, Diagnostic Electromyography (D-EMG) signal interpretation of human arm towards characterization of arm-muscle interaction during various arm movements has been discussed. EMG signals from four important arm muscle (i.e., Bicepsbracci, Tricepsbracci, brachioradialis, and lateral deltoids) are recorded clinically during five different arm movements (i.e., Extension of the forearm, flexion of elbow joint, pronation of forearm, shoulder abduction, and Wrist flexor stretch) under load condition (a load of 2 Kg & 4 Kg maintained during experimental arm movement), the recorded D-EMG signals are properly enveloped within a range of 5–100 Hz and quantized within a proper sampling frequency range to produce a knowledge-based database of muscle activity. In addition, correlation of muscle activity and Power spectral density (PSD) analysis has been carried out towards muscle process discriminating during various arm actions.

4 October 2024 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
PCPritam Chakraborty
Pritam Chakraborty
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
ADAchintya Das
Achintya Das

7 March 2022 in Revista Română de Informatică şi Automatică
Verified
Journal Article
Closed access
PCPritam Chakraborty
Pritam Chakraborty
SBSwati Barui
Swati Barui
ADAchintya DAS
Achintya DAS
Biswarup NeogiBiswarup Neogi
Biswarup Neogi

21 February 2024 in Research Square
Verified
Preprint
Open access
PDF file
PCPritam Chakraborty
Pritam Chakraborty
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
ADAchintya Das
Achintya Das
Mu FaheemMu Faheem
Mu Faheem
RBRajesh Bose
Rajesh Bose
SRSANDIP ROY
SANDIP ROY
This research investigates the kinematic characteristics of shoulder and scapula movement during the Arnold press exercise, focusing on the joints of interest including the acromion (l-ai), lateral tip of the scapula (l-ts), C7 vertebra, and T8 vertebra. Using motion capture technology, three-dimensional coordinates of these anatomical landmarks were recorded to capture the dynamic motion patterns. State space reconstruction was performed with optimized embedding dimensions determined to be 7 for l-ai, 8 for l-ts, and 1 for both C7 and T8. Recur- rence Quantification Analysis (RQA) was employed to analyze the recurrence properties of the reconstructed state space, revealing %recurrence rate values of 0.8933 for l-ai, 0.2358 for l-ts, 1.2973 for C7, and 1.2916 for T8.Additionally, recur- rence entropy values were computed to be 20.17 for l-ai, 26.18 for l-ts, 26.44 for C7, and 26.30 for T8, indicating the level of predictability and complexity in the motion patterns. Furthermore, Lyapunov exponents were calculated to assess the system’s sensitivity to initial conditions, with values of 0.3724 for l-ai, -0.3230 for C7, 0.2904 for T8, and 0.27 for l-ts. These findings provide valuable insights into the dynamic behavior and coordination of shoulder and scapula movement during the Arnold press exercise, with implications for optimizing exercise performance and injury prevention strategies.