Zeljko Kos

Prof. Zeljko Kos

University North, Varaždin, Croatia
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
ZKZeljko Kos
Zeljko Kos
SKSergii Kroviakov
Sergii Kroviakov
VKVitalii Krzyhanovskyi
Vitalii Krzyhanovskyi
DHDaria Hedulian
Daria Hedulian
A comparison of the effect of steel and polypropylene fibers on the strength, frost resistance, abrasion, and corrosion resistance in an acidic environment of fiber-reinforced concrete for industrial floors and road pavements was carried out. Steel fibers with a length of 50 mm and a diameter of 1 mm and polypropylene fibers with a length of 36 mm and a diameter of 0.68 mm were used. The amount of steel fiber varied from 15 to 25 kg/m3, and the amount of polypropylene fiber varied from 2 to 3 kg/m3. It has been established that steel fiber more significantly increases the concrete compressive strength, and both types of dispersed reinforcement increase the flexural strength equally by 27–34%. Also, dispersed reinforcement reduces the concrete abrasion resistance by 15–35% and increases its frost resistance by 50 cycles, which helps to improve the durability of industrial floors and road pavements. The use of steel fiber in an amount of 20 kg/m3 and polypropylene fiber in an amount of 2.5 kg/m3 also increases the concrete corrosion resistance in an acidic environment. In general, dispersed reinforcement with both fiber types has approximately the same technological effect concerning the mentioned applications. However, the use of polypropylene fibers is economically more profitable since an increase in the cost of 1 m3 of concrete with steel fiber reinforcement is from $22.5 to $37.5, and an increase in cost with polypropylene fiber is from $10 to $15.

23 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZKZeljko Kos
Zeljko Kos
SKSergii Kroviakov
Sergii Kroviakov
VKVitalii Krzyhanovskyi
Vitalii Krzyhanovskyi
IGIryna Grynyova
Iryna Grynyova
High-early strength fiber-reinforced concretes are effective materials for the full depth repair of rigid highway and airfield pavements. A comprehensive study was carried out on the influence of the amount of steel anchor fiber and hardening accelerator on properties that are important for repairing concrete. A two-factor experiment was carried out, in which the influence of the hardening accelerator and fiber dosages on the strength, frost resistance, wear resistance and shrinkage of repaired steel-fiber-reinforced concrete for rigid pavements was studied. The investigated concretes contained 400 kg/m3 of cement and polycarboxylate plasticizer in the amount of 1.2% of the cement content. It has been established that the optimal concrete compositions are with the amount of Sika Rapid 3 hardening accelerator from 1 to 2% of the cement content and the steel fiber amount from 60 to 90 kg/m3. Optimal fiber-reinforced concrete compositions have a reduced shrinkage during hardening, and at the age of 2 days they have a compressive strength of at least 55 MPa and a flexural strength of at least 8.5 MPa. At the design age, the fiber-reinforced concrete compressive strength is 85–90 MPa, its flexural strength ranges from 15.5 to 17.5 MPa, it has a frost resistance of F200 and abrasion not higher than 0.24 g/cm2. These properties ensure the high durability of the repair material.

11 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZKZeljko Kos
Zeljko Kos
YKYevhenii Klymenko
Yevhenii Klymenko
IKIrina Karpiuk
Irina Karpiuk
IGIryna Grynyova
Iryna Grynyova
This work presents a proposed engineering method for calculating the bearing capacity of the supporting sections of continuous monolithic reinforced concrete tape beams, which combine pressed or driven reinforced concrete piles into a single foundation design. According to the mechanics of reinforced concrete, it is recommended to consider the grillage to be a continuous reinforced concrete beam, which, as a rule, collapses according to the punching scheme above the middle support (pile caps), with the possible formation of a plastic hinge above it. The justification for the proposed method included the results of experimental studies, comparisons of the experimental tensile shear force with the results of calculations according to the design standards of developed countries, and modeling of the stress-strain state of the continuous beam grillage in the extreme span and above the middle support-pile adverse transverse load in the form of concentrated forces. The work is important, as it reveals the physical essence of the phenomenon and significantly clarifies the physical model of the operation of inclined sections over the middle support. The authors assessed the influence of design factors in continuous research elements, and on the basis of this, the work of the investigated elements under a transverse load was simulated in the Lira-Sapr PC to clarify the stress-strain state and confirm the scheme of their destruction adopted in the physical model by the finite element method in nonlinear formulation. Based on the analysis and comparison of the experimental and simulation results, a design model was proposed for bearing capacity near the supporting sections of continuous reinforced concrete beams and high grillages that is capable of adequately determining their strength.

28 August 2023 in Materials
Verified
Journal Article
Open access
PDF file
ZKZeljko Kos
Zeljko Kos
SKSergii Kroviakov
Sergii Kroviakov
AMAndrii Mishutin
Andrii Mishutin
APAndrii Poltorapavlov
Andrii Poltorapavlov
The complex effect of the amount of cement, polypropylene fiber (the fiber length was 39 mm, and the diameter was 0.45 mm), and polycarboxylate superplasticizer on concrete properties for rigid pavement was determined using the methods of experiment planning and experimental–statistical modeling. The fluidity of all the mixtures was S1. The W/C of the mixtures depended on the composition of the concrete and variable from 0.32 to 0.46. It was found that, by increasing the amount of superplasticizer from 1% to 1.8–2%, the compressive strength of concrete increased by 4.5–6 MPa after 3 days and by 7–9 MPa after 28 days. The flexural strength in this case increased by 0.6–0.9 MPa. The use of polypropylene fiber in the amount of 1.5–1.8 kg/m3 increased the compressive strength of concrete by an average of 3 MPa, increased the flexural strength by 0.5–0.6 MPa, reduced the abrasion capacity by 9–14%, and increased the frost resistance by up to 50 cycles. When using a rational amount of superplasticizer and fiber, the compressive strength of concrete, even with a minimum cement amount of 350 kg/m3, was at least 65 MPa, its flexural strength was at least 6 MPa, its frost resistance was F200, and its abrasion capacity was not more than 0.30 g/cm2. Concrete with such properties can be used for roadways of any type. Low abrasion capacity and high frost resistance provide the necessary durability of concrete for rigid pavement during operation.

1 September 2023 in Magazine of Concrete Research
Verified
Journal Article
Closed access
ZKZeljko Kos
Zeljko Kos
SKSergii Kroviakov
Sergii Kroviakov
VKVitalii Krzyhanovskyi
Vitalii Krzyhanovskyi
ACAndjelko Crnoja
Andjelko Crnoja
This paper investigates the influence of hardening accelerator and steel fibre on concrete adhesion strength for the repair of rigid highway and airfield pavements. The concretes were mixed based on CEM II/A-S 42.5 and included MasterGlenium SKY 608 superplasticiser. Experiments with two variable concrete composition factors were carried out. The amount of steel fibre varied from 0 to 100 kg/m3 and the amount of SikaRapid hardening accelerator varied from 0 to 9.6 kg/m3. It was found that modified repair concretes have a sufficiently high adhesion strength to ‘old’ concrete, from 2.30 MPa when tested by the pull-off method and from 2.05 MPa when tested by the flexural strength test method. Fibre-reinforcement increases the adhesion strength of repaired concrete by 7–15% due to the reduction of shrinkage during hardening. Treating the contact surface of ‘old’ concrete with a primer additionally increases adhesion strength by 6–10%. The maximum adhesion strength of fibre-reinforced concrete to the base reaches 3 MPa. Due to the high early and design strength, modified steel fibre-reinforced concrete provides the possibility of quick resumption of traffic while ensuring the integrity of the road structure due to the joint work of the repair material with the old concrete repair area.

1 November 2019 in Tehnicki vjesnik - Technical Gazette
Verified
Journal Article
Open access
PDF file
LDLovorka Gotal Dmitrovic
Lovorka Gotal Dmitrovic
ZKZeljko Kos
Zeljko Kos
YKYvgenii Klimenko
Yvgenii Klimenko
Any damage to the column and in particular the reducing of the cross section, requires steps to repair the columns, taking temporary measures in the form of taking part of the load and / or reducing the useful load on the damaged column....