This study analyzed the effects of applications of flexible alternating current transmission system (FACTS) devices, such as a thyristor controlled series capacitor (TCSC) and static var compensator (SVC) to handle the oscillations due to wind penetration in an existing network, and to exploit the AC lines to their thermal limits. A small signal stability analysis of an interconnected power system with wind penetration in the presence of FACTS and a power system stabilizer (PSS) was studied under a diverse range of operating conditions. The coordinated tuning of SVC and PSS parameters as well as a TCSC in the presence of a wind energy conversion system was analyzed. The salp swarm algorithm, a recently developed meta-heuristic approach, was used for tuning TCSC, SVC, and PSS parameters. The supremacy of TCSC over SVC for improving system stability was demonstrated under a diverse range of operating conditions.
3 August 2020 in Journal of Electrical Engineering & Technology
Due to the interaction of electric multiple units (EMUs), and the electric traction networks, low frequency oscillations (LFOs) appear leading to traction blockade and overall stability related issues. For suppressing LFOs, coronavirus herd immunity optimiser (CHIO), a recently developed meta‐heuristic, has been applied for tuning controller parameters. Controller parameters are tuned to minimise the integral time absolute error (ITAE) that regulates DC‐link capacitor voltage. Results obtained using CHIO are compared with those found using other well‐established algorithms like symbiotic organisms search (SOS) and particle swarm optimisation (PSO). The supremacy of CHIO over other mentioned algorithms for mitigating LFOs was demonstrated for a diverse range of operating conditions. Results demonstrates that overshoot for the proposed algorithm‐based traction unit is 1.0061% whereas those for SOS and PSO based algorithm are obtained as 6.4542 % and 20.6166%, respectively which are quite high. CHIO is more stable than SOS and PSO and requires settling time of 0.1934 s only to reach steady‐state condition, which is 50.21% faster than SOS and 65.03% faster than PSO. Also, the total harmonic distortion (THD) for line currents of the secondary side of traction transformer (TT) are obtained as 0.88%, 2.17%, and 12.48% for CHIO, SOS, and PSO, respectively.
21 August 2023 in IEEE Transactions on Transportation Electrification
This paper presents a modeling technique to characterize the system-wide magnetic interference that impacts track-side safety in the early design of a DC electrified monorail system. A simulation algorithm based on the 2D finite-difference method is implemented to accommodate Poisson’s equation for cross-component magnetic coupling between nearby power lines and system infrastructure. This also takes into account the interaction with the train-track electrification through the movement performance and power flow simulations. This computational scheme estimates the track-side area exposed to strong magnetic fields, thus revealing the impermissible area in accordance with EN 50121-4 and EN 45502-2-1. The earthing arrangement of metallic walkways and cable trays in the middle of the guideway is also examined to prevent electrocution with respect to EN 50122-1 criteria. Numerical results indicate that, for the operation under steady-state AC-line faults, an additional 15% and 12.39% of high-risk areas shall be accounted for in the space utilization management of equipment and persons, respectively. It can also be seen that the mitigation measure of allowing up to 4 guideway-beam spans per earthing point is reasonable to reduce the risk of electric shock hazard. The outlined numerical scheme could provide proper guidance for early confidence prior to system installation.
Identifying the fault type and faulted phase prior to protection coordination and restoration of the remaining healthy part of the utility power grid in the presence of railway traction load is an important process to ensure power supply system reliability of the grid-connected traction network. An artificial neural network (ANN) based fault classifier has been proposed. The input features to the classifier are derived from multiple detail coefficients of modal current traveling wave signals using the three-level discrete wavelet transform (DWT) with the Daubechies-6 mother wavelet (db6). The Bayesian regularization backpropagation as a supervised machine learning algorithm performs through more than a thousand fault scenarios. The robustness of the proposed DWT-ANN algorithm is verified by testing with the IEEE 9-bus network connected with the large railway traction system through MATLAB Simulink simulations. The superiority in fault identification performance of the proposed algorithm is evident with the highest accuracy of 100% when compared with similar methods.