Catarina Nunes

Dr. Catarina Nunes


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Inês FranciscoInês Francisco
Inês Francisco
CNCatarina Nunes
Catarina Nunes
FPFlávia Pereira
Flávia Pereira
RTRaquel Travassos
Raquel Travassos
Madalena Prata RibeiroMadalena Prata Ribeiro
Madalena Prata Ribeiro
Francisco ValeFrancisco Vale
Francisco Vale
Dual-energy X-ray absorptiometry is used to determine bone density in several pathologies, namely osteoporosis and fracture risk in post-menopausal women. The aim of this study was to identify, appraise and synthesize all available evidence about the correlation between Dual Energy X-ray Absorptiometry (DEXA) and Cone Beam Computed Tomography (CBCT) techniques through a systematic review. A systematic literature search was conducted in the following databases: PubMed via MEDLINE, Cochrane Library, EMBASE and Web of Science Core Collection, along with several sources of grey literature. The Cochrane Risk of Bias Tools were used to perform the qualitative assessment of the selected studies. A total of 913 articles were initially scrutinized and 11 were included for qualitative analysis, of which 3 were included in a meta-analysis. Most of the included studies revealed a low risk of bias (7 out of 11). A strong correlation (min r = 0.46 max r = 0.62) between DEXA and CBCT values were found. Thus, opportunistic CBCT scans may be used to assess the bone mineral density and fracture risk, improving the ability to track disease progression and providing better care.

Verified
Journal Article
Open access
PDF file
Inês FranciscoInês Francisco
Inês Francisco
ÂBÂngela Basílio
Ângela Basílio
Madalena Prata RibeiroMadalena Prata Ribeiro
Madalena Prata Ribeiro
CNCatarina Nunes
Catarina Nunes
RTRaquel Travassos
Raquel Travassos
Francisco ValeFrancisco Vale
Francisco Vale
Craniofacial bone defects are one of the biggest clinical challenges in regenerative medicine, with secondary autologous bone grafting being the gold-standard technique. The development of new three-dimensional matrices intends to overcome the disadvantages of the gold-standard method. The aim of this paper is to put forth an in-depth review regarding the clinical efficiency of available 3D printed biomaterials for the correction of alveolar bone defects. A survey was carried out using the following databases: PubMed via Medline, Cochrane Library, Scopus, Web of Science, EMBASE, and gray literature. The inclusion criteria applied were the following: in vitro, in vivo, ex vivo, and clinical studies; and studies that assessed bone regeneration resorting to 3D printed biomaterials. The risk of bias of the in vitro and in vivo studies was performed using the guidelines for the reporting of pre-clinical studies on dental materials by Faggion Jr and the SYRCLE risk of bias tool, respectively. In total, 92 publications were included in the final sample. The most reported three-dimensional biomaterials were the PCL matrix, β-TCP matrix, and hydroxyapatite matrix. These biomaterials can be combined with different polymers and bioactive molecules such as rBMP-2. Most of the included studies had a high risk of bias. Despite the advances in the research on new three-dimensionally printed biomaterials in bone regeneration, the existing results are not sufficient to justify the application of these biomaterials in routine clinical practice.

26 August 2022 in Biomimetics
Verified
Journal Article
Open access
PDF file
Francisco ValeFrancisco Vale
Francisco Vale
Anabela Baptista Pereira PaulaAnabela Baptista Pereira Paula
Anabela Baptista Pereira Paula
RTRaquel Travassos
Raquel Travassos
CNCatarina Nunes
Catarina Nunes
Madalena Prata RibeiroMadalena Prata Ribeiro
Madalena Prata Ribeiro
Inês FranciscoInês Francisco
Inês Francisco
Velopharyngeal insufficiency may occur as a result of an anatomical or structural defect and may be present in patients with cleft lip and palate. The treatment options presented in the literature are varied, covering invasive and non-invasive methods. However, although these approaches have been employed and their outcomes reviewed, no conclusions have been made about which approach is the gold-standard. This umbrella review aimed to synthesize the current literature regarding velopharyngeal insufficiency treatments in cleft lip and palate patients, evaluating their effectiveness based on systematic reviews. A standardized search was carried out in several electronic databases, namely PubMed via Medline, Web of Science, Cochrane Library, and Embase. The quality of the included studies was evaluated using AMSTAR2 and degree of overlap was analyzed using Corrected Covered Area. Thirteen articles were included in the qualitative review, with only 1 in the non-invasive method category, and 12 in the invasive method category. All reviewed articles were judged to be of low quality. In symptomatic patients, treatment did not solely comprise speech therapy, as surgical intervention was often necessary. Although there was no surgical technique considered to be the gold standard for the correction of velopharyngeal insufficiency, the Furlow Z-plasty technique and minimal incision palatopharyngoplasty were the best among reported techniques.

3 November 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
Francisco ValeFrancisco Vale
Francisco Vale
CNCatarina Nunes
Catarina Nunes
JRJoana Reis
Joana Reis
RTRaquel Travassos
Raquel Travassos
Madalena Prata RibeiroMadalena Prata Ribeiro
Madalena Prata Ribeiro
Inês FranciscoInês Francisco
Inês Francisco
(1) Background: Cleft lip and palate is the most common congenital malformation of the head and neck. After surgical closure, velopharyngeal dysfunction can arise, which has implications for phonation, sucking, swallowing, middle ear function, and interpersonal well-being. This case series aimed to present an adaptation of the conventional pharyngeal obturator design in order to allow its use with fixed orthodontic appliances. (2) Methods: A new custom-made pharyngeal obturator device was built in order to enable a correct function of the velopharyngeal valve. The fabrication of the plate was made by altering the conventional Hawley retainer, replacing the Adams hooks with 0.9 mm spherical hooks and removing the buccal arch. (3) Results: The new pharyngeal obturator design was used in six cleft patients with fixed orthodontic appliances. The appliance was well tolerated and there was a slight improvement in auditory-perceptive evaluations. (4) Conclusions: The new pharyngeal bulb design proved to have good retention during fixed orthodontic treatment. Moreover, despite the short-term follow-up, it also showed a reduction in the severity of the hypernasality sentences.

16 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MMMiguel Piçarra Monteiro
Miguel Piçarra Monteiro
Francisco ValeFrancisco Vale
Francisco Vale
NFNuno Ferreira
Nuno Ferreira
FMFilipa Marques
Filipa Marques
Madalena Prata RibeiroMadalena Prata Ribeiro
Madalena Prata Ribeiro
FCFrancisco Caramelo
Francisco Caramelo
Orthognathic surgery is a procedure used to correct intermaxillary discrepancies, thus promoting significant improvements in chewing and breathing. During the surgical planning stage, orthodontists often use two-dimensional imaging techniques. The assessment is based on CBCT images and dental cast models to overcome these limitations; however, the evaluation of soft tissues remains complex. The aim of the present study was to develop a co-registration method of CBCT and photo images that would result in realistic facial image reconstruction. CBCT images were three-dimensionally rendered, and the soft tissues were subsequently segmented resulting in the cranial external surface. A co-registration between the obtained surface and a frontal photo of the subject was then carried out. From this mapping, a photorealistic model capable of replicating the features of the face was generated. To assess the quality of this procedure, seven orthodontists were asked to fill in a survey on the models obtained. The survey results showed that orthodontists consider the three-dimensional model obtained to be realistic and of high quality. This process can automatically obtain a three-dimensional model from CBCT images, which in turn may enhance the predictability of surgical-orthognathic planning.

18 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Inês FranciscoInês Francisco
Inês Francisco
APAna Lúcia Pinto
Ana Lúcia Pinto
CNCatarina Nunes
Catarina Nunes
Madalena Prata RibeiroMadalena Prata Ribeiro
Madalena Prata Ribeiro
FCFrancisco Caramelo
Francisco Caramelo
Francisco ValeFrancisco Vale
Francisco Vale
Background: The development of the curve of Spee (CoS) is influenced by skeletal morphology, orofacial growth, tooth eruption timing, mandibular relationships, overbite, and neuromuscular development. This systematic review aims to determine the most effective orthodontic methods in correcting the curve of Spee. Methods: The systematic review protocol was registered on the PROSPERO platform and conducted according to the Cochrane and PRISMA guidelines. For its development, a standardized search was performed across different databases (MEDLINE, Cochrane Library, Embase and Web of Science) and grey literature. The risk of bias was assessed using Faggion, Jr.’s guidelines for in vitro and in silico studies of dental materials, and the Rob-2 and ROBINS-1 tools for clinical studies. Results: The initial search found 748 studies, with 44 selected after full-text review. Of these, 22 were included in the quantitative analysis, assessing the effectiveness of braces (with or without extractions) and invisible aligners. Key methods for correcting the curve of Spee include various orthodontic archwires (nickel–titanium (NiTi), stainless steel, beta-titanium), continuous and segmented techniques, reverse curve archwires, aligners, and treatment modalities including extraction protocols. Most in vitro studies and randomized studies had a high risk of bias, and non-randomized studies showed moderate to high bias risk. Conclusions: The results suggest that conventional techniques, particularly non-extraction approaches, may be more effective than aligners in correcting the curve of Spee, although the available evidence remains limited.