Background: Immune-checkpoint inhibitors (ICI), including nivolumab and pembrolizumab, are among the standard treatments for previously treated advanced gastric cancer (AGC). This study aimed to evaluate the frequency of immune-related adverse events (irAEs) and the correlation between irAEs and their efficacy in AGC cases. Patients and Methods: Patients were divided into two groups according to irAE occurrence. The frequency of irAEs and the treatment outcome (response rate [RR], progression-free survival [PFS], and overall survival [OS]) were evaluated. The survival rates were evaluated by landmark analysis considering lead-time bias. Results: Among 108 patients who received nivolumab or pembrolizumab, 17 (15.7%) had irAEs. In a 4-week landmark analysis, the RR, median PFS, and median OS were 28.5%, 3.9 months (95% CI=2.8-9.3), and 12.2 months (95% CI=3.8-NA) in patients with irAEs, while 3.0% (2/65), 1.8 months (95% CI=1.4-2.1), and 3.5 months (95% CI, 2.9-5.1) in patients without irAEs, respectively. In multivariate analysis, irAEs were associated with better PFS (HR=2.08, 95% CI=1.34-3.21). Conclusion: The occurrence of irAEs was associated with a better clinical outcome of ICIs in patients with AGC.
Background and aim: During endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNB), Franseen needles can help collect sufficient tissue to permit histopathological assessment. However, its efficacy might be limited by the size of the targeted lesion. This study aimed to evaluate the feasibility of histopathological assessment of small solid pancreatic lesions using a 22-gauge Franseen needle during EUS-FNB. Methods: This retrospective study evaluated data from all patients who underwent EUS-FNB using a Franseen needle for solid pancreatic lesions at the University of Toyama Hospital between June 2018 and April 2020. Results: The study included 159 patients who had 152 malignant lesions and 7 benign lesions. The malignant lesions included pancreatic cancers (n = 134), neuroendocrine neoplasms (n = 15), metastatic tumors (n = 2), and a solid pseudopapillary neoplasm (n = 1). The diagnostic accuracy of EUS-FNB (combining histology and cytology) was 98.7%. However, the histopathological diagnosis was only confirmed for 64.3% of small lesions (<10 mm), relative to 97.2% for larger lesions. Multivariate analysis also revealed that lesion size of <10 mm predicted a less accurate histopathological diagnosis (odds ratio: 6.97, 95% confidence interval: 1.02–47.67; p = 0.041). Further analyses revealed a failed histological diagnosis in 4 patients with lesions of <5 mm in size and accurate diagnoses in 9 out of 10 patients with lesions of 5–10 mm in size. Conclusions: The diagnostic accuracy for small lesions (<10 mm), especially for lesions of 10 mm). Furthermore, multivariate analysis revealed that only lesion size was an independent predictor of histopathological diagnosis accuracy.
Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) enables easy and accurate pathological assessment. Here, we compared and assessed the area of samples on glass slides for three needle types: a 19-gauge Franseen needle (Acquire, Boston Scientific, Natick, MA, USA), a 22-gauge Franseen needle, and a 19-gauge fine-needle aspiration (FNA) needle (EZ Shot 3 Plus; Olympus, Tokyo, Japan). Among patients with suspected pancreatic cancer, with a ≥20 mm tumor located in the pancreatic body and tail, and who underwent EUS-FNA or FNB between June 2018 and March 2020, 10 were randomly selected to test each needle. The areas of histological tissue and blood clot samples were measured using the BZ-X800 imaging software (Keyence Corporation, Osaka, Japan). Baseline patient characteristics and pathological sample data showed no significant differences among the needles. The 19-gauge Franseen needle obtained significantly more histological tissue samples than the 19-gauge conventional needle (p = 0.010) and 22-gauge Franseen needle (p = 0.008). Conversely, there was no significant difference between the 19-gauge conventional needle and 22-gauge Franseen needle (p = 0.838) in this regard. The 19-gauge Franseen needle could collect more samples than the other needles, contributing to giving a more precise pathological diagnosis and more information, including genomic profiling.
This study aimed to assess the utility of the S-O clip during colorectal endoscopic submucosal dissection (ESD). We conducted a retrospective study on 185 patients who underwent colorectal ESD from January 2015 to January 2020. The patients were divided into two groups: before and after the introduction of the S-O clip. Forty-two patients underwent conventional ESD (CO group) and 29 patients underwent ESD using the S-O clip (SO group). We compared the surgery duration, dissection speed, en bloc resection rate, and complication rate between both groups. Compared with the CO group, the SO group had a significantly shorter surgery duration (70.7 ± 37.9 min vs. 51.2 ± 18.6 min; p = 0.017), a significantly higher dissection speed (15.1 ± 9.0 min vs. 26.3 ± 13.8 min; p < 0.001), a significantly higher en bloc resection rate (80.9% vs. 98.8%; p ≤ 0.001), and a significantly lower perforation rate (4.3% vs. 1.3%). In the right colon, the surgery duration was significantly shorter and the dissection speed was significantly higher in the SO group than in the CO group. Moreover, the rate of en bloc resection improved significantly in the right colon. S-O clip-assisted ESD reduces the procedure time and improves the treatment effects, especially in the right colon.
3 July 2024 in International Journal of Radiation Oncology, Biology, Physics