Yifan Li

Dr. Yifan Li

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2020 in Processes
Verified
Journal Article
Open access
PDF file
HOHang Ouyang
Hang Ouyang
JZJiusun Zeng
Jiusun Zeng
YLYifan Li
Yifan Li
SLShihua Luo
Shihua Luo
It is of critical importance to keep a steady operation in the blast furnace to facilitate the production of high quality hot metal. In order to monitor the state of blast furnace, this article proposes a fault detection and identification method based on the multidimensional Gated Recurrent Unit (GRU) network, which is a kind of recurrent neural network and is highly effective in handling process dynamics. Comparing to conventional recurrent neural networks, GRU has a simpler structure and involves fewer parameters. In fault detection, a moving window approach is applied and a GRU model is constructed for each process variable to generate a series of residuals, which is further monitored using the support vector data description (SVDD) method. Once a fault is detected, fault identification is performed using the contribution analysis. Application to a real blast furnace fault shows that the proposed method is effective.

26 June 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
PTPorui Tian
Porui Tian
YLYifan Li
Yifan Li
In the development of micro/nano fluid control systems, fluid resistance has always been one of the key factors restricting its development. According to previous studies, it is found that the boundary slip effect of the solid-liquid interface can effectively reduce the resistance of the microfluid and improve the transport efficiency of the microfluid. The boundary slip length is mainly affected by surface wettability, roughness, and surface charge density. Among them, the influence mechanism of surface charge density on the boundary slip is the most complicated, and there is a lack of relevant research, and further investigation is needed. In this paper, we present research on quantification of effective slip length and surface charge density, where the roughness effect is considered. The electrostatic and hydrodynamic force data obtained from atomic force microscopy (AFM) measurements were fitted and processed for comparative analysis. We obtained the variation of surface charge density and effective slip length when different oleophobic surface samples were immersed in ethylene glycol with different pH values. The effect of pH on the surface charge density and effective slip length was investigated by their variations. The mechanism of the effect of pH on the surface charge density was discussed. The experimental results show that in the ethylene glycol solution, no matter whether the pH value of the solution increases or decreases, the charge density of the surface with the same properties decreases, and the effective boundary slip length also shows a downward trend. In deionized water, the surface charge density and effective boundary slip length decreases with the decrease of PH value.

17 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
WYWenshu Yue
Wenshu Yue
YLYifan Li
Yifan Li
JCJinhui Cai
Jinhui Cai
Portable blood glucose meters are commonly evaluated using test strips and control solutions, which assess the combined meter–strip–reagent response but are not designed to provide a directly controlled, pre-characterized electrical stimulus for repeated meter-side verification. This study developed a portable electrical response verification system based on dynamic microcurrent reproduction using a calibrated programmable current source. At each of two control solution levels, five 1000-point test strip current responses were acquired. Each response was reduced to 100 points by averaging every 10 consecutive samples, and the five reduced responses were then averaged point by point to obtain one level-specific mean reference waveform. Each mean waveform was converted into a 100-point DAC code table for STM32-controlled reproduction. The current source provided a measured output range of 0.016–9.829 μA. Five repeated reproductions per level yielded mean Pearson correlation coefficients of 0.9993 and 0.9995 and peak current CV values of 2.52% and 1.59%, respectively. The corresponding GA-3 meter (Sinocare Inc., Changsha, Hunan, China) readings differed from the mean original readings by 1.70% and 1.18%, with CV values of 1.81% and 1.29%. These results support the feasibility of controlled electrical response verification and short-term repeatability assessment of strip-based blood glucose meters.

21 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YLYupeng Li
Yupeng Li
YLYifan Li
Yifan Li
Micro-nano measurement represents a critical engineering focus in the advancement of micro-nano fabrication technologies. Exploring advanced micro-nano measurement methods is a key direction for driving progress in micro-nano manufacturing. This study proposes a confocal measurement method utilizing a liquid crystal spatial light modulator (LC-SLM) to simulate a binary Fresnel lens for 3D focusing, enabling the non-mechanical measurement of spatial positions on sample surfaces. Specifically, it introduces a 3D focusing method based on LC-SLM, constructs a confocal microscopy 3D focusing system, and conducts lateral focusing experiments and axial focusing experiments. Experimental results demonstrate that the system can freely adjust lateral focusing positions. Within an axial focusing range of 900 μm, it achieves axial measurement accuracy exceeding 1 μm, with a maximum resolution capability of approximately 16.667 nm. Compared to similar confocal microscopy systems, this method allows rapid adjustment of lateral focusing positions without regenerating phase grayscale maps, achieves comparable axial measurement accuracy, and enhances measurement speed.