Analysis of kinematic features related to clinical assessment scales may qualitatively improve the evaluation of upper extremity movements of stroke patients. We aimed to investigate kinematic features that could correlate the change in the Fugl-Meyer Assessment (FMA) score of stroke survivors through upper extremity robotic rehabilitation. We also analyzed whether changes in kinematic features by active and active-assisted robotic rehabilitation correlated differently with changes in FMA scores. Fifteen stroke patients participated in the upper extremity robotic rehabilitation program, and nine kinematic features were calculated from reach tasks for assessment. Simple and multiple linear regression analyses were used to characterize correlations. Features representing movement speed were associated with changes in FMA scores for the group that used an active rehabilitation robot. In contrast, in the group that used an active-assisted rehabilitation robot, features representing movement smoothness were associated with changes in the FMA score. These estimates can be an important basis for kinematic analysis to complement clinical scales.
20 October 2023 in Journal of NeuroEngineering and Rehabilitation
Background: Foot drop is a neuromuscular disorder that causes abnormal gait patterns. This study developed a pneumatically powered ankle-foot orthosis (AFO) to improve the gait patterns of patients with foot drop. We hypothesized that providing unilateral ankle dorsiflexion assistance during the swing phase would improve the kinematics and spatiotemporal gait parameters of such patients. Accordingly, this study aims to examine the efficacy of the proposed assistance system using a strategy for joint kinematics and spatiotemporal gait parameters (stride length, swing velocity, and stance phase ratio). The analysis results are expected to provide knowledge for better design and control of AFOs in patients with foot drop. Method: Ten foot drop patients with hemiparesis (54.8 y ± 14.1 y) were fitted with a custom AFO with an adjustable calf brace and portable air compressor for ankle dorsiflexion assistance in the gait cycle during the swing phase. All subjects walked under two different conditions without extensive practice: (1) barefoot and (2) wearing a powered AFO. Under each condition, the patients walked back and forth on a 9-m track with ten laps of level ground under the supervision of licensed physical therapists. The lower-limb joint and trunk kinematics were acquired using 12 motion-capture cameras. Results: We found that kinematic asymmetry decreased in the three lower-limb joints after ankle dorsiflexion assistance during the swing phase. The average ankle-joint angle increased after using the AFO during the entire gait cycle. Similarly, the knee-joint angle showed a slight increase while using the AFO, leading to a significantly decreased standard deviation within patients. Conversely, the hip-joint angle showed no significant improvements with assistance. While several patients exhibited noticeably lower levels of asymmetry, no significant changes were observed in the average asymmetry of the swing velocity difference between the affected and unaffected sides while using the AFO. Conclusion: We experimentally validated that ankle dorsiflexion assistance during the swing phase temporarily improves gait asymmetry in foot-drop patients. The experimental results also prove the efficacy of the developed AFO for gait assistance in foot-drop patients.
As the number of patients with amputations increases, research on assistive devices such as prosthetic limbs is actively being conducted. However, the development of assistive devices for patients with partial amputations is insufficient. In this study, we developed a finger prosthesis for patients with partial amputations. The design and mathematical modeling of the prosthesis are briefly presented. A pneumatic actuator, based on the McKibben muscle design, was employed to drive the finger prosthesis. We characterized the relationship between the actuator’s force and axial length changes with varying pressure. An empirical model derived from conventional mathematical modeling of force and axis length changes was proposed and compared with experimental data, and the error was measured to be between about 3% and 13%. In order to control the actuator using an electromyography (EMG) signal, an electrode was attached to the user’s finger flexors. The EMG signal was measured in relation to the actual gripping force and was provided with visual feedback, and the magnitude of the signal was evaluated using root mean square (RMS). Depending on the evaluated EMG signal magnitude, the pressure of the actuator was continuously adjusted. The pneumatic pressure was adjusted between 100 kPa and 250 kPa, and the gripping force of the finger prosthesis ranged from about 0.7 N to 6.5 N. The stiffness of the prosthesis can be varied using the SMA spring. The SMA spring is switched to a fully austenite state at 50 °C through PID control, and when the finger prosthesis is bent to a 90° angle, it can provide approximately 1.2 N of assistance force. Finally, the functional evaluation of the finger prosthesis was performed through a pinch grip test of eight movements.
8 June 2020 in International Journal of Precision Engineering and Manufacturing
Tactile sensing can enhance robotic grasping by providing contact information unavailable from vision or control signals alone. However, implementing tactile sensing in robotic hands is often constrained by external wiring, data-acquisition hardware, power requirements, and limited fingertip space. This study presents a self-contained capacitive tactile fingertip module for adding wireless multi-point contact sensing to robotic grippers. The module integrates a 3 × 1 array of thin flexible capacitive sensors, a capacitance-to-digital converter, a Bluetooth-enabled microcontroller, and an onboard battery within a compact fingertip-shaped housing. It can be mounted in place of an existing fingertip and operates independently of the robotic hand controller. Individual sensors characterized before module integration responded near-linearly to normal compression up to 2.5 N, with an approximately 8% relative capacitance change at 2.5 N and R2 = 0.99, and were evaluated over 100 repeated compression cycles. In proof-of-concept grasping tests with an empty PET bottle, a water-filled PET bottle, and a water-filled aluminum tumbler, the assembled module produced distinguishable capacitance changes at the mid- and proximal-position sensors, providing relative information on contact location and local loading rather than calibrated force. These results demonstrate the feasibility of wireless tactile sensing in robotic grasping using a compact standalone fingertip module.
While lightweight and highly back-drivable exoskeletons enable natural interaction by minimizing resistance to voluntary motion, few studies have investigated the resulting combined physiological and biomechanical effects of unilateral hip torque assistance. This paper presents a hip exoskeleton designed to provide unilateral torque assistance during walking to investigate the effects of unilateral actuation on lower-limb muscle responses. The device employs a quasi-direct-drive actuator and a simplified angle-based control scheme to deliver torque in phase with the hip flexion. Although the mechanical frame was bilaterally symmetrical, only the right hip joint was actuated to evaluate the effects of unilateral assistance while maintaining inertial balance and low mechanical impedance on the unpowered side. Three healthy participants walked on a treadmill under different load (0, 1, and 2 kg) and assistive torque (0, 6, and 9 N·m) conditions. Subsequently, surface electromyography and motion capture data were recorded simultaneously. The activity of the rectus femoris muscle consistently decreased, showing over 30% reduction compared to that observed during unassisted walking under loaded conditions. Furthermore, postural deviation was measurably reduced by up to 46.8% during assisted conditions without hindering the natural swing. These findings demonstrate that a lightweight unilaterally actuated exoskeleton can provide evident physiological benefits even with a minimal control strategy. Notably, moderate torque (6 N·m) proved to be sufficient for yielding significant benefits, in some cases outperforming higher torque levels (9 N·m). This suggests that optimizing assistance levels based on user-specific needs is crucial for maximizing walking comfort and supporting rehabilitation in future designs.