Fridolin Heidler

Prof. Fridolin Heidler


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
CKChristian Krystian Karch
Christian Krystian Karch
FHFridolin Heidler
Fridolin Heidler
CPChristian Paul
Christian Paul
The aim of this contribution is to design and test the lightning protection of an aircraft radome exposed to direct lightning strikes. The influencing parameters are investigated on different radome wall samples equipped with solid and segmented diverter strips. The effectiveness of the lightning interception and protection measures is tested with different high-voltage waveforms and representative high-current pulses. The tests show that reliable radome lightning protection can be achieved by an optimized arrangement of solid and segmented diverter strips, even if the aircraft radome has a huge size, with dimensions up to several meters.

14 February 2018 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
CPChristian Paul
Christian Paul
FHFridolin Heidler
Fridolin Heidler
Channel base currents from natural lightning have been measured on the new top structure of the Peissenberg Tower, Germany, since 2008. Here, an analysis is given of the impulsive currents, called initial continuous current (ICC)-pulses, that occurred during the ICC, and of the impulsive currents, called M-component currents, that occurred during the continuing current following return strokes. It was found that the M-component currents and the ICC-pulses closely resemble each other. The 45 flashes analyzed were exclusively negative upward lightning containing 60 return strokes and 264 impulsive currents (79 M-components and 185 ICC-pulses). A total of 246 (93.2%) impulsive currents were negative ones, and 18 (6.8%) impulsive currents were positive ones. The majority of 83.7% were pure impulsive currents and the minority of 16.3% were combined impulsive currents composed by two or more pure impulsive currents. For the pure impulsive currents, the analysis revealed three different types of waveforms for both the M-component currents and the ICC-pulses. The currents of the first type have a more or less symmetrical wave shape. For the 27 M-component currents and the 103 ICC-pulses (values in parentheses) of the first type, the geometric mean values are 0.7 (0.5) kA for the peak value, 23.9 (24.7) μs for the 10%-to-90% risetime, 101.0 (96.5) μs for the full width at half-maximum (FWHM), and 94.3 (57.1) mC for the transferred charge. The impulsive currents of the second type have a bipolar wave shape with current reversal. For the 31 M-component currents and the 37 ICC-pulses of the second type, the geometric mean values are 0.9 (0.6) kA for the peak value, 11.8 (16.9) μs for the 10%-to-90% risetime, 60.6 (74.7) μs for the FWHM, and −42.4/58.5 (−34.1/26.5) mC for the negative/positive charge of the bipolar pulses. The impulsive currents of the third type have a wave shape, which exhibits a fast rise to peak and a much longer decay to low current values. For the 5 M-component currents and the 18 ICC-pulses of the third type, the geometric mean values are 1.0 (1.2) kA for the current peak, 1.2 (2.9) μs for the 10%-to-90% risetime, 56.8 (29.0) μs for the FWHM, and 44.8 (24.03) mC for the transferred charge.


12 April 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
FHFridolin Heidler
Fridolin Heidler
CPChristian Paul
Christian Paul
Subject matter of the paper is the analysis of the return stroke characteristics of negative lightning flashes recorded with the Peissenberg Measuring Station, Germany. Four negative first return strokes were measured. All of them were single-stroke lightning having a first stroke, but no subsequent stroke. The arithmetic mean value is 42.8 kA for the peak current, 7.4 μs for the 10% to 90% current risetime, 13.5 C for the charge, 182·103 A2s for the specific energy (action integral), and 15.5 kA/μs for the maximum current steepness. The associated electric fields exhibited a field change of opposite polarity prior to the initiation of the return stroke current. The same waveform was found for the electric field of other triggered negative upward lightning, except of the different time scale. The currents of the total of 105 negative subsequent return strokes were also recorded, 68 of them with the measurement equipment were used up to the year 1999, and 37 of them with the new measurement equipment were used since 2008. Based on the measurements up to 1999, the arithmetic mean values of the current peak and of the maximum current derivative are 9 kA and 45 kA/μs, respectively. For the measurements since 2008, the arithmetic mean value of the current peak is 10.1 kA.

10 November 2020 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
FHFridolin Heidler
Fridolin Heidler
CPChristian Paul
Christian Paul
In this article, we analyzed the optical images from high-speed video recordings and the time-correlated waveforms of the current, the electric field, and the magnetic field from four negative upward lightning which struck the Peissenberg Tower, Germany. Two of them were self-initiated ones and two of them were other-triggered ones. From the illumination in the video images, leader activity could clearly be detected during the occurrence of the first of the other-triggered lightning. In contrast, no illumination by leader activity could be found during the occurrence of the second other-triggered lightning and the time period of 2.5 s before. In addition, the current pulses superimposing the initial continuous current/continuing current were examined differing between those which developed in luminous or nonluminous branches. From the total of 26 current pulses which developed in nonluminous branches, 25 (96%) of them had a 10–90%-rise time less than 4 μs, and 23 (88%) of them had a 10–90%-rise time even less than 2 μs. Because the current waveforms resemble those of weak return stroke, we assume that the current pulses indeed represent the leader/return stroke mode of charge transfer to ground. The return strokes were extremely weak, with an arithmetic mean of 2.59 kA (GM: 2.08 kA) for the current peak. On the other hand, from the total of 74 current pulses which developed in already luminous branches, none of them had a 10–90%-rise time less than 4.4 μs. The arithmetic mean is 29.8 μs and the geometric mean is 20.5 μs. Due to the relatively long rise time, we assume that these current pulses represent the M-component mode of charge transfer to ground.

22 January 2019 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
FHFridolin Heidler
Fridolin Heidler