Antonin Glac

Mr. Antonin Glac

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2025 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
JŠJakub Ševčík
Jakub Ševčík
VŠVáclav Šmídl
Václav Šmídl
AGAntonin Glac
Antonin Glac
Flux linkage maps (FLMs) are routinely used in high-precision control and modeling of synchronous machines. Common methods often consider only the dependence of the FLM on the stator currents, allowing for convenient representation in lookup tables or neural networks. However, the flux linkage also depends on speed, position, and other state variables. Although this is formally simple to add as an additional input to neural models of FLM, the estimation with additional inputs becomes more demanding. We demonstrate that the conventional approach of FLM training using the assumption of a steady-state regime is insufficient to learn the dependency on the rotor position. It is necessary to use the complete ordinary differential equation of the current to learn the FLM model. Even for a shallow neural model of the FLM, the estimation procedure yields a deep learning task known as neural ODE. This procedure essentially generates multistep ahead prediction of differential equations and minimizes the mismatch between the mathematical model and data. The efficiency of this approach is demonstrated on the FLM of a synchronous machine considering flux saturation, speed dependence, and slot harmonics. The proposed approach significantly improves current prediction, yielding improved deadbeat current control. The results are experimentally verified on a 4.5 kW laboratory prototype.

19 August 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
AGAntonin Glac
Antonin Glac
VŠVáclav Šmídl
Václav Šmídl
ZPZdeněk Peroutka
Zdeněk Peroutka
Christoph Michael HacklChristoph Michael Hackl
Christoph Michael Hackl
The efficiency of an IPMSM motor is influenced by the operating point of the machine. Conventional approaches to generate measured efficiency maps may be too expensive to use in some situations, thus it often replaced by simpler variants based on parametric models. A promising approach is to combine model-based approaches with online parameter identification methods which would allow following changes of the parameters. However, such approaches may also result in deteriorated performance if the online parameter estimation is inaccurate. We present a systematic experimental study of the influence of the parameter estimates on the efficiency of a 4.5 kW IPMSM drive and analyze the sources of inaccuracy. The first outcome of this study is that none of the tested methods performs well when the machine is fully loaded, which deteriorates overall performance. The second outcome is that the conventional maximum torque per ampere/current (MTPA/MTPC) is not an accurate optimization criterion. The overall performance of the compared methods thus heavily depends on the testing profile. When a significant part of the profile is at full load, the methods based on online estimation are unsuitable and parameters estimated offline using frequency domain provides better efficiency under the maximum torque per current control strategy.

29 December 2022 in Actuators
Verified
Journal Article
Open access
PDF file
VŠVáclav Šmídl
Václav Šmídl
AGAntonin Glac
Antonin Glac
ZPZdeněk Peroutka
Zdeněk Peroutka
We are concerned with the problem of fast and accurate tracking of currents in the general synchronous drive. The problem becomes complicated with decreasing available voltage, which is common in high-speed and field weakening regimes. The existing time-optimal controllers rely on a simplified model, ignoring stator resistance and differences in inductances. We derive a solution for the general model considering all parameters and show how the parameters affect the current trajectory. One simplifying assumption had to be made, but we show in simulation that it has a negligible impact on accuracy. The simplification allowed for the design of a feed-forward controller that has a low computational cost and can be easily implemented in realtime. We provide experimental validation of the controller on the developed IPMSM drive prototype of the rated power of 4.5 kW using conventional industrial DSP. The controller is compared to conventional PI and deadbeat solutions, demonstrating that the time-optimal controller can reach the required setpoint four times faster than the competitors at the field weakening regime of the drive. The proposed feed-forward control can be seen as a universal building block that can be combined with existing feedback controllers and observers and thus incorporated into existing control solutions.

15 December 2025 in Electronics
Verified
Journal Article
Open access
PDF file
KHKarel Hruska
Karel Hruska
AGAntonin Glac
Antonin Glac
OSOndrej Suchy
Ondrej Suchy
This paper presents an analytically derived optimal control strategy for wound-rotor synchronous machines (WRSM) based on minimising the Joule losses in both the stator and rotor windings. The presented control strategy is analysed in terms of analytical derivation, machine current ratios, working regions and constraints. It is experimentally verified on a salient-pole wound-rotor synchronous machine with strongly non-linear equivalent circuit parameters. The verification was performed in two stages: first, considering constant equivalent circuit parameters while assessing strong non-linear behaviour of the machine leading to significant discrepancies in the resulting machine torque. In the second stage, after determination of non-linear machine parameters using measured flux maps, identical control methodology is analysed in terms of variations in ratios between machine currents. Using pre-calculated current ratios the same control methodology is extended for machines with strongly non-linear equivalent circuit parameters and verified in a real environment. The measurement confirms expected machine behaviour in all available control regions achievable by used synchronous motor as well as limits between these control regions. The results of the verification in a real environment show a discrepancy of approximately 5% in measured machine torque in comparison to expected value confirming the validity of the analytically derived approach and introduced modifications for machines with non-linear equivalent circuit parameters.