Hsiao-Wen  Zan

Prof. Hsiao-Wen Zan


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2017 in ACS Sensors
Verified
Journal Article
Closed access
LCLiang-Yu Chang
Liang-Yu Chang
MCMing-Yen Chuang
Ming-Yen Chuang
HZHsiao-Wen Zan
Hsiao-Wen Zan
HMHsin-Fei Meng
Hsin-Fei Meng
CLChia-Jung Lu
Chia-Jung Lu
JCJian-Nan Chen
Jian-Nan Chen

8 June 2012 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
HZHsiao-Wen Zan
Hsiao-Wen Zan
CYChun‐Cheng Yeh
Chun‐Cheng Yeh
HMHsin‐Fei Meng
Hsin‐Fei Meng
CTChuang‐Chuang Tsai
Chuang‐Chuang Tsai
LCLiang‐Hao Chen
Liang‐Hao Chen

12 August 2022 in ACS Photonics
Verified
Journal Article
Closed access
TLTzu-Yi Lee
Tzu-Yi Lee
LCLi-Yin Chen
Li-Yin Chen
YLYu-Yun Lo
Yu-Yun Lo
SSSujith Sudheendran Swayamprabha
Sujith Sudheendran Swayamprabha
AKAmit Kumar
Amit Kumar
HKHao-Chung Kuo
Hao-Chung Kuo

31 October 2020 in Biomedicines
Verified
Journal Article
Open access
PDF file
MCMing-Jen Chan
Ming-Jen Chan
YLYi-Jung Li
Yi-Jung Li
CWChao-Ching Wu
Chao-Ching Wu
YLYu-Chen Lee
Yu-Chen Lee
HZHsiao-Wen Zan
Hsiao-Wen Zan
YTYa-Chung Tian
Ya-Chung Tian
Chronic kidney disease (CKD) is a public health problem and its prevalence has increased worldwide; patients are commonly unaware of the condition. The present study aimed to investigate whether exhaled breath ammonia via vertical-channel organic semiconductor (V-OSC) sensor measurement could be used for rapid CKD screening. We enrolled 121 CKD stage 1–5 patients, including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients, from July 2019 to January 2020. Demographic and laboratory data were recorded. The exhaled ammonia was collected and rapidly measured by the V-OSC sensor to correlate with kidney function. Results showed no significant difference in age, sex, body weight, hemoglobin, albumin level, and comorbidities in different CKD stage patients. Correlation analysis demonstrated a good correlation between breath ammonia and blood urea nitrogen levels, serum creatinine levels, and estimated glomerular filtration rate (eGFR). Breath ammonia concentration was significantly elevated with increased CKD stage compared with the previous stage (CKD stage 1/2/3/4/5: 636 ± 94; 1020 ± 120; 1943 ± 326; 4421 ± 1042; 12781 ± 1807 ppb, p < 0.05). The receiver operating characteristic curve analysis showed an area under the curve (AUC) of 0.835 (p < 0.0001) for distinguishing CKD stage 1 from other CKD stages at 974 ppb (sensitivity, 69%; specificity, 95%). The AUC was 0.831 (p < 0.0001) for distinguishing between patients with/without eGFR < 60 mL/min/1.73 m2 (cutoff 1187 ppb: sensitivity, 71%; specificity, 78%). At 886 ppb, the sensitivity increased to 80% but the specificity decreased to 69%. This value is suitable for kidney function screening. Breath ammonia detection with V-OSC is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy.

17 November 2017 in ACS Sensors
Verified
Journal Article
Closed access
MCMing-Yen Chuang
Ming-Yen Chuang
CCChang-Chiang Chen
Chang-Chiang Chen
HZHsiao-Wen Zan
Hsiao-Wen Zan
HMHsin-Fei Meng
Hsin-Fei Meng
CLChia-Jung Lu
Chia-Jung Lu

15 November 2010 in Applied Physics Letters
Verified
Journal Article
Closed access
HZHsiao-Wen Zan
Hsiao-Wen Zan
WCWei-Tsung Chen
Wei-Tsung Chen
HHHsiu-Wen Hsueh
Hsiu-Wen Hsueh
SKShih-Chin Kao
Shih-Chin Kao
MKMing-Che Ku
Ming-Che Ku
HMHsin-Fei Meng
Hsin-Fei Meng
This work demonstrates a real-time visible-light phototransistor comprised of a wide-band-gap amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistor (TFT) and a narrow-band-gap polymeric capping layer. The capping layer and the IGZO layer form a p-n junction diode. The p-n junction absorbs visible light and consequently injects electrons into the IGZO layer, which in turn affects the body voltage as well as the threshold voltage of a-IGZO TFT. The hysteresis behavior due to the charges at IGZO back interface is also discussed.