The specific nature of work in nuclear medicine departments involves the use of isotopes and handling procedures, which contribute to the considerable value of an equivalent dose received, in particular, by the fingertips. Standard nuclear medicine department uses ring dosemeters placed usually at the base of the middle finger. The main aim of the study was to find out whether a relationship exists between the doses recorded by thermoluminescent detectors placed at various locations on the radiopharmacists' hands and the doses recorded by the ring detectors, and to determine the character of that relationship. The correction factor represents a correction value to be used to calculate the doses which might be received by locations on the hand from the dose recorded by the ring dosemeter. The dose recorded by the ring dosemeter is on the average five times lower than that received by the fingertips of thumb, index and middle fingers.
The aim of the study was to assess the effect of three different types of anaesthesia on perioperative bleeding control and to analyse the mean arterial blood pressure and heart rate in patients undergoing endoscopic paranasal sinus surgery. Ninety patients (30 women and 60 men, aged 18–85 years) scheduled to undergo functional endoscopic sinus surgery in the years 2008–2010 were identified as candidates for inclusion in the study. Patients were randomly assigned to one of three groups (30 patients each) according to the type of general anaesthesia to be administered. Groups I and II both received inhalation anaesthesia (sevoflurane for sedation) and intravenous anaesthesia (fentanyl in group I, remifentanil in group II). Anaesthesia was delivered solely via intravenous route (TIVA) in group III, with propofol used for sedation and remifentanil for analgesia. Blood pressure and heart rate were monitored during surgery and post-surgically for 4 h. Mean anaesthesia duration in groups I, II and III was 108.7 ± 20.8, 112.6 ± 22.2 and 103.7 ± 17.5 min and the surgery duration was 71.3 ± 16.7, 78.8 ± 24.2 and 66.5 ± 15.5 min, respectively. Mean blood loss during surgery was 365.0 ± 176.2, 340.0 ± 150.5 and 225.0 ± 91.7 ml, with a mean blood loss rate of 5.1 ± 2.4, 4.5 ± 2.2 and 3.4 ± 1.1 ml/min in groups I, II and III, respectively. Technologically advanced control of the drug dose with the TIVA technique allows for better control of perioperative bleeding.
Introduction: Cigarette smoke and alcohol can generate reactive oxygen species, which may induce DNA double-strand breaks (DSBs), the most serious DNA lesion. In humans, DSBs are repaired mainly by non-homologous end joining and homologous recombination repair (HRR). Several polymorphisms in...
1 December 2010 in Experimental and Molecular Pathology
Background: The genes of base excision repair (BER) pathway have been extensively studied in the association with various human cancers. We performed a case-control study to test the association between two common single nucleotide polymorphisms (SNPs) of XRCC1 gene with human head and neck squamous cell carcinoma (HNSCC). Methods: The genotype analysis of Arg194Trp and Arg399Gln gene polymorphisms for 92 HNSCC patients and 124 controls of cancer free subjects, in Polish population were performed using the PCR-based restriction fragment length polymorphism (PCR-RFLP) with endonuclease Msp I. Results: No altered risk has been found individually for these SNPs, however haplotypes analysis showed high association with head and neck cancer. The highest frequency, according to wild-type of Arg194Arg and Arg399Arg genotypes, was identified for Arg194Trp-Arg399Arg haplotype (OR, 2.96; 95% CI, 1.01–8.80). Conclusion: Finally, we identified the combined Arg194Trp-Arg399Arg genotype of base excision repair gene XRCC1 that was associated with HNSCC and may have an impact on identification of a high-risk cancer population.