Michele Scipioni

Dr. Michele Scipioni

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2021 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
Maria Filomena SantarelliMaria Filomena Santarelli
Maria Filomena Santarelli
DGDario Genovesi
Dario Genovesi
Vincenzo PositanoVincenzo Positano
Vincenzo Positano
MSMichele Scipioni
Michele Scipioni
GVGiuseppe Vergaro
Giuseppe Vergaro
PMPaolo Marzullo
Paolo Marzullo

25 January 2018 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
NFNiccolo Fuin
Niccolo Fuin
OCOnofrio Antonio Catalano
Onofrio Antonio Catalano
MSMichele Scipioni
Michele Scipioni
LCLisanne P.W. Canjels
Lisanne P.W. Canjels
DGDavid Izquierdo Garcia
David Izquierdo Garcia
CCCiprian Catana
Ciprian Catana
Purpose: We present an approach for concurrent reconstruction of respiratory motion compensated abdominal DCE-MRI and PET data in an integrated PET/MR scanner. The MR and PET reconstructions share the same motion vector fields (MVFs) derived from radial MR data; the approach is robust to changes in respiratory pattern and do not increase the total acquisition time. Methods: PET and DCE-MRI data of 12 oncological patients were simultaneously acquired for 6 minutes on an integrated PET/MR system after administration of 18 F-FDG and gadoterate meglumine. Golden-angle radial MR data were continuously acquired simultaneously with PET data and sorted into multiple motion phases based on a respiratory signal derived directly from the radial MR data. The resulting multidimensional dataset was reconstructed using a compressed sensing approach that exploits sparsity among respiratory phases. MVFs obtained using the full 6-minute (MC_6-min) and only the last 1 minute (MC_1-min) of data were incorporated into the PET reconstruction to obtain motion-corrected PET images and in an MR iterative reconstruction algorithm to produce a series of motion-corrected DCE-MRI images (moco_GRASP). The motion-correction methods (MC_6-min and MC_1-min) were evaluated by qualitative analysis of the MR images and quantitative analysis of maximum and mean standardized uptake values (SUVmax, SUVmean), contrast, signal-to-noise ratio (SNR) and lesion volume in the PET images. Results: Motion corrected MC_6-min PET images demonstrated 30%, 23%, 34% and 18% increases in average SUVmax, SUVmean, contrast and SNR, and an average 40% reduction in lesion volume with respect to the non-motion-corrected PET images. The changes in these figures of merit were smaller but still substantial for the MC_1-min protocol: 19%, 10%, 15% and 9% increases in average SUVmax , SUVmean, contrast and SNR; and a 28% reduction in lesion volume. Moco_GRASP images were deemed of acceptable or better diagnostic image quality with respect to conventional breath hold cartesian VIBE acquisitions. Conclusion: We presented a method that allows the simultaneous acquisition of respiratory motion-corrected diagnostic quality DCE-MRI and quantitatively accurate PET data in an integrated PET/MR scanner with negligible prolongation in acquisition time compared to routine PET/DCE-MRI protocols.

11 July 2018 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
OCOnofrio Antonio Catalano
Onofrio Antonio Catalano
LULale Umutlu
Lale Umutlu
NFNiccolo Fuin
Niccolo Fuin
MHMatthew Louis Hibert
Matthew Louis Hibert
MSMichele Scipioni
Michele Scipioni
CCCiprian Catana
Ciprian Catana

1 October 2016 in Computers in Biology and Medicine
Verified
Journal Article
Open access
Maria Filomena SantarelliMaria Filomena Santarelli
Maria Filomena Santarelli
DLDaniele Della Latta
Daniele Della Latta
MSMichele Scipioni
Michele Scipioni
Vincenzo PositanoVincenzo Positano
Vincenzo Positano
Luigi LandiniLuigi Landini
Luigi Landini
Positron emission tomography (PET) in medicine exploits the properties of positron-emitting unstable nuclei. The pairs of γ- rays emitted after annihilation are revealed by coincidence detectors and stored as projections in a sinogram. It is well known that radioactive decay follows a Poisson distribution; however, deviation from Poisson statistics occurs on PET projection data prior to reconstruction due to physical effects, measurement errors, correction of deadtime, scatter, and random coincidences. A model that describes the statistical behavior of measured and corrected PET data can aid in understanding the statistical nature of the data: it is a prerequisite to develop efficient reconstruction and processing methods and to reduce noise. The deviation from Poisson statistics in PET data could be described by the Conway-Maxwell-Poisson (CMP) distribution model, which is characterized by the centring parameter λ and the dispersion parameter ν, the latter quantifying the deviation from a Poisson distribution model. In particular, the parameter ν allows quantifying over-dispersion (ν1) of data. A simple and efficient method for λ and ν parameters estimation is introduced and assessed using Monte Carlo simulation for a wide range of activity values. The application of the method to simulated and experimental PET phantom data demonstrated that the CMP distribution parameters could detect deviation from the Poisson distribution both in raw and corrected PET data. It may be usefully implemented in image reconstruction algorithms and quantitative PET data analysis, especially in low counting emission data, as in dynamic PET data, where the method demonstrated the best accuracy.

11 September 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Maria Filomena SantarelliMaria Filomena Santarelli
Maria Filomena Santarelli
AMAnna Mori
Anna Mori
MBMichelangelo Bertasi
Michelangelo Bertasi
Vincenzo PositanoVincenzo Positano
Vincenzo Positano
AGAlessia Gimelli
Alessia Gimelli
Luigi LandiniLuigi Landini
Luigi Landini
A technical comparison is described between two SPECT systems, one dedicated to cardiovascular studies and one general-purpose, to evaluate the advantages and disadvantages of their use in an organ-specific clinical setting. The comparison was made between a dedicated cardiac SPECT (Alcyone, Discovery NM 530c, GE Healthcare) scanner and a general-purpose one (Discovery NM/CT 670 CZT, GE Healthcare). The two scanners differ in terms of hardware, mainly in the arrangement of the detectors and collimators, which are the main components of SPECT. A standard NEMA phantom was used to characterize the energy resolution, spatial resolution, and sensitivity for the two systems. Then, using a custom-made cardiac phantom, more specific indices were computed to evaluate the quality of cardiac images, such as signal-to-background noise ratio (SBNR), tissue-background contrast-to-noise ratio (TBCNR), and uniformity. Finally, the same indices were computed for clinical images acquired with the two systems from 11 subjects. Alcyone showed superior performance for dedicated cardiac imaging; however, its excellent qualities are aimed only at the study of the heart and only at patients with a low body-mass index, unlike Discovery NM/CT 670 CZT, which can be used for every anatomic district area and for every type of patient.

12 June 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MSMichele Scipioni
Michele Scipioni
SPStefano Pedemonte
Stefano Pedemonte
Maria Filomena SantarelliMaria Filomena Santarelli
Maria Filomena Santarelli
Luigi LandiniLuigi Landini
Luigi Landini
In the context of dynamic emission tomography, the conventional processing pipeline consists of independent image reconstruction of single time frames, followed by the application of a suitable kinetic model to time-activity curves (TACs) at the voxel or region-of-interest level. Direct 4D PET reconstruction, by contrast, seeks to move beyond this scheme and incorporate information from multiple time frames within the reconstruction task. Established direct methods are based on a deterministic description of voxelwise TACs, captured by the chosen kinetic model, considering the photon counting process the only source of uncertainty. In this work, we introduce a new probabilistic modeling strategy based on the key assumption that activity time course would be subject to uncertainty even if the parameters of the underlying dynamic process are known. This leads to a hierarchical model, which we formulate using the formalism of Probabilistic Graphical Modeling. The inference is addressed using a new iterative algorithm, in which kinetic modeling results are treated as prior expectation of activity time course, rather than as a deterministic match, making it possible to control the trade-off between a data-driven and a model-driven reconstruction. The proposed method is flexible to an arbitrary choice of (linear and nonlinear) kinetic models, it enables the inclusion of arbitrary (sub)differentiable priors for parametric maps, and it is simple to implement. Computer simulations and an application to a real patient scan show how the proposed method is able to generalize over conventional indirect and direct approaches, providing a bridge between them by properly tuning the impact of the kinetic modeling step on image reconstruction.