DNA electrotransfer is a successful technique for gene delivery into cells and represents an attractive alternative to virus-based methods for clinical applications including gene therapy and DNA vaccination. However, little is currently known about the mechanisms governing DNA internalization and its fate inside cells. The objectives of this work were to investigate the role of endocytosis and to quantify the contribution of different routes of cellular trafficking during DNA electrotransfer. To pursue these objectives, we performed flow cytometry and single-particle fluorescence microscopy experiments using inhibitors of endocytosis and endosomal markers. Our results show that ≃50% of DNA is internalized by caveolin/raft-mediated endocytosis, 25% by clathrin-mediated endocytosis, and 25% by macropinocytosis. During active transport, DNA is routed through multiple endosomal compartments with, in the hour following electrotransfer, 70% found in Rab5 structures, 50% in Rab11-containing organelles and 30% in Rab9 compartments. Later, 60% of DNA colocalizes with Lamp1 vesicles. Because these molecular markers can overlap while following organelles through several steps of trafficking, the percentages do not sum up to 100%. We conclude that electrotransferred DNA uses the classical endosomal trafficking pathways. Our results are important for a generalized understanding of gene electrotransfer, which is crucial for its safe use in clinics.
12 January 2016 in Angewandte Chemie International Edition
We present a compact coherent anti-Stokes Raman scattering microscope based on a widely tunable picosecond Er:fiber laser. Intense and bandwidth-limited 1 ps pump pulses at a center wavelength of 775 nm are generated via frequency mixing within the broadband fundamental at 1.55 μm. Narrowband Stokes pulses are obtained by frequency shifting of solitons in a highly nonlinear bulk fiber and subsequent second-harmonic generation. The tuning range from 850 nm to 1100 nm gives access to vibrational resonances between and . A first imaging application in the spectral region of CH stretch vibrations is demonstrated.
We demonstrate a scheme for efficient coherent anti-Stokes Raman scattering (CARS) microscopy free of nonresonant background. Our method is based on a compact Er:fiber laser source. Impulsive excitation of molecular resonances is achieved by an pulse at . Broadband excitation gives access to molecular resonances from up to . Time-delayed narrowband probing at enables sensitive and high-speed spectral detection of the CARS signal free of nonresonant background with a resolution of .