Anna Boehm

Mrs. Anna Boehm

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2016 in Electronics
Verified
Journal Article
Open access
PDF file
ABAnna Boehm
Anna Boehm
XYXinchi Yu
Xinchi Yu
WNWilko Neu
Wilko Neu
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
DTDaniel Teichmann
Daniel Teichmann
We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403). The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.

25 July 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SSSusana Aguiar Santos
Susana Aguiar Santos
ARAnne Robens
Anne Robens
ABAnna Boehm
Anna Boehm
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
DTDaniel Teichmann
Daniel Teichmann
A new prototype of a multi-frequency electrical impedance tomography system is presented. The system uses a field-programmable gate array as a main controller and is configured to measure at different frequencies simultaneously through a composite waveform. Both real and imaginary components of the data are computed for each frequency and sent to the personal computer over an ethernet connection, where both time-difference imaging and frequency-difference imaging are reconstructed and visualized. The system has been tested for both time-difference and frequency-difference imaging for diverse sets of frequency pairs in a resistive/capacitive test unit and in self-experiments. To our knowledge, this is the first work that shows preliminary frequency-difference images of in-vivo experiments. Results of time-difference imaging were compared with simulation results and shown that the new prototype performs well at all frequencies in the tested range of 60 kHz–960 kHz. For frequency-difference images, further development of algorithms and an improved normalization process is required to correctly reconstruct and interpreted the resulting images.

7 November 2017 in Electronics
Verified
Journal Article
Open access
PDF file
ABAnna Boehm
Anna Boehm
XYXinchi Yu
Xinchi Yu
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
DTDaniel Teichmann
Daniel Teichmann
Unobtrusively acquired electrocardiograms (ECG) could substantially improve the comfort of patients. However, such ECGs are not used in clinical practice because (among other reasons) signal deformations impede correct diagnosis of the ECG. Here, methods are proposed for correction of the unobtrusive ECG, based on system identification. Knowing the reference ECG, models were developed to correct the unobtrusively acquired ECG. A finite impulse response (FIR) model, a state space model and an autoregressive model were developed. The models were trained and evaluated on the Goldberger leads recorded from an ECG T-shirt with dry electrodes, and from a gold standard ECG. It was found that the FIR model corrects the unobtrusive ECG with good agreement ( ρ aVR = 0.84 ± 0.10, ρ aVL = 0.65 ± 0.24, ρ aVF = 0.88 ± 0.04), while the other models do not yield significant improvements, or become unstable. The R-peaks were also accurately corrected by the FIR model ( MSE aVR = 0.10 ± 0.10, MSE aVL = 0.14 ± 0.27, MSE aVF = 0.03 ± 0.02). To conclude, the proposed FIR method succeeded in significantly correcting the unobtrusive ECG signal.