Cheng Hu

Dr. Cheng Hu

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2009 in Safety Science
Verified
Journal Article
Closed access
CJC.S. Jiang
C.S. Jiang
YDY.F. Deng
Y.F. Deng
CHCheng Hu
Cheng Hu
HDH. Ding
H. Ding
W.K. ChowW.K. Chow
W.K. Chow

Verified
Journal Article
Open access
PDF file
MLMenghang Liu
Menghang Liu
LLLuning Li
Luning Li
QLQiang Li
Qiang Li
YBYu Bai
Yu Bai
CHCheng Hu
Cheng Hu
Open public places, such as pedestrian streets, parks, and squares, are vulnerable when the pedestrians thronged into the sidewalks. The crowd count changes dynamically over time with various external factors, such as surroundings, weekends, and peak hours, so it is essential to predict the accurate and timely crowd count. To address this issue, this study introduces graph convolutional network (GCN), a network-based model, to predict the crowd flow in a walking street. Compared with other grid-based methods, the model is capable of directly processing road network graphs. Experiments show the GCN model and its extension STGCN consistently and significantly outperform other five baseline models, namely HA, ARIMA, SVM, CNN and LSTM, in terms of RMSE, MAE and R2. Considering the computation efficiency, the standard GCN model was selected to predict the crowd. The results showed that the model obtains superior performances with higher prediction precision on weekends and peak hours, of which R2 are above 0.9, indicating the GCN model can capture the pedestrian features in the road network effectively, especially during the periods with massive crowds. The results will provide practical references for city managers to alleviate road congestion and help pedestrians make smarter planning and save travel time.

4 July 2019 in Journal of Advanced Transportation
Verified
Journal Article
Open access
PDF file
DWDa-Wei Wang
Da-Wei Wang
LLLu-Ning Li
Lu-Ning Li
CHCheng Hu
Cheng Hu
QLQiang Li
Qiang Li
XCXiang Chen
Xiang Chen
PHPin-Wen Huang
Pin-Wen Huang
Urban open places with a public service function (e.g., urban parks) are likely to be populated in peak hours and during public events. To mitigate the risk of overcrowding and even events of stampedes, it is of considerable significance to realize a real-time full coverage estimate of the population density. The main challenge has been the limited deployment of crowd surveillance detectors in open public spaces, leading to incomplete data coverage and thus impacting the quality and reliability of the density estimation. To remedy this issue, this paper proposes a modified inverse distance weighting (IDW) method, named the inverse distance weighting based on path selection behavior (IDWPSB) method. The proposed IDWPSB method adjusts the distance decay effect according to visitors’ path selection behavior, which better characterizes the human dynamics in open spaces. By implementing the model in a real-world road network in the Shichahai scenic area in Beijing, China, the study shows a decrease in the absolute deviation by 17.62% comparing the results between the new method and the traditional IDW method, justifying the effectiveness of the new method for spatial interpolation in open public places. By considering the behavioral factor, the proposed IDWPSB method can provide insights into public safety management with the increasing availability of data derived from location-based services.

1 January 2012 in Procedia Engineering
Verified
Journal Article
Open access
JLJunmei Li
Junmei Li
XXXuefei Xing
Xuefei Xing
CHCheng Hu
Cheng Hu
YLYanfeng Li
Yanfeng Li
CYChenchen Yin
Chenchen Yin
SLShanshan Liu
Shanshan Liu
Double-skin façade is more and more popular in modern buildings in recently years due to it can provide the building with improved thermal and sound insulation compared with a traditional glazed facade. But fire safety is a problem, the inner glass wall broken during a fire would lead to the smoke and flame spread to the adjacent levels, this might be dangerous for the occupants in those areas. Many such projects failed to comply with the fire safety codes at present. Engineering approach similar to performance-based fire codes practicing in some countries was applied to demonstrate the design is safe. Fire hazard assessment should be supported by the further investigations on the smoke and fire spread in DSF. Cavity depth effects, one of the key factors which can influence the smoke flow in DSF would be studied by numerical method in this paper. By examining the results for cavity depth of 0.5, 1.0 and 1.5 m, it is found that a wider cavity might give better fire safety under the scenarios studied. The outer glass panel would be broken rapidly for the cavity of 0.5m deep. a Cavity depth of 1.0 m might be the most risky design comparing with the other two cavity depths studied, the inner glass panel might be broken before the outer panel, this might lead to the fire spread to the adjacent upper levels, high strength glasses should be used or other protection measures should be taken for the DSF design under this condition. Further studied should be required for an in-depth understanding the smoke and fire spread in DSF in the further

1 September 2009 in Architectural Science Review
Verified
Journal Article
Closed access
CJC. S. Jiang
C. S. Jiang
YLY. Ling
Y. Ling
CHCheng Hu
Cheng Hu
ZYZ. Yang
Z. Yang
Han DingHan Ding
Han Ding
W.K. ChowW.K. Chow
W.K. Chow
A case study of the modelling emergency evacuation of a typical subway station in Beijing is presented in this paper. The objectives of the study are to assess the evacuation capability with different passenger loadings, compare the results with the requirements in the current code for the design of subways in China, and design practical and effective evacuation management measures. Four groups of scenarios under different passenger loadings are identified after discussions with different parties. Evacuation patterns are studied by the software building EXODUS with 23 scenarios. The attributes and flow of passengers in this study are based on the statistical data reported in previous research. These included field surveys in three operating lines from 1996 to 2001; video-recordings on the normal evacuation of the three stations in 2004; and data collected recently at the actual subway stations during weekdays and holidays. The potential influence of various factors in each group is systematically...

15 October 2013 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
JLJun Mei Li
Jun Mei Li
CYChen Chen Yin
Chen Chen Yin
CHCheng Hu
Cheng Hu
YLYan Feng Li
Yan Feng Li
PXPeng Xu
Peng Xu
The fire in high-rise buildings is perhaps more dangerous than those occur in normal buildings because of the strong stack effect and wind effect on the fire. The wind effects on the wind flame spread across the exterior wall of the high rise building are studied in this paper by the numerical methods. The results show that high wind speed will change the wind flame spread direction and make the room inclined above the fire room more danger, especially the room at the same floor adjacent to the fire room. Special passive fire protection measures should be taken under these kinds of conditions.