Kostadin Ganev

Dr. Kostadin Ganev

National Institute of Geophysics, Geodesy and Geography—Bulgarian Academy of Sciences, Acad. G. Bonchev str., bl. 3 1113 Sofia, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2010 in Earth Science Informatics
Verified
Journal Article
Closed access
PDF file
ATAngelina Todorova
Angelina Todorova
DSDimiter Syrakov
Dimiter Syrakov
Georgi GadzhevGeorgi Gadzhev
Georgi Gadzhev
GGGeorgi Georgiev
Georgi Georgiev
Kostadin GanevKostadin Ganev
Kostadin Ganev
KSKiril Slavov
Kiril Slavov

1 August 2008 in Ecological Modelling
Verified
Journal Article
Closed access
Kostadin GanevKostadin Ganev
Kostadin Ganev
MPMaria Prodanova
Maria Prodanova
DSDimiter Syrakov
Dimiter Syrakov
NMNikolai Miloshev
Nikolai Miloshev

26 June 2014
Verified
Book Chapter
Closed access
PDF file
Georgi GadzhevGeorgi Gadzhev
Georgi Gadzhev
Kostadin GanevKostadin Ganev
Kostadin Ganev
NMNikolay Miloshev
Nikolay Miloshev
DSDimiter Syrakov
Dimiter Syrakov
MPMaria Prodanova
Maria Prodanova

22 August 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Georgi GadzhevGeorgi Gadzhev
Georgi Gadzhev
Kostadin GanevKostadin Ganev
Kostadin Ganev
Air pollution is responsible for many adverse effects on human beings. Thermal discomfort, on the other hand, is able to overload the human body and eventually provoke health implications due to the heat imbalance. Methods: The aim of the presented work is to study the behavior of two bio-climatic indices and statistical characteristics of the air quality index for Sofia city—the capital of Bulgaria for the period 2008–2014. The study is based on the WRF-CMAQ model system simulations with a spatial resolution of 1 km. The air quality is estimated by the air quality index, taking into account the influence of different pollutants and the thermal conditions by two indices, respectively, for hot and cold weather. It was found that the recurrence of both the heat and cold index categories and of the air quality categories have heterogeneous space distribution and well manifested diurnal and seasonal variability. For all of the situations, only O3 and PM10 are the dominant pollutants—these which determine the AQI category. It was found that AQI1, AQI2, and AQI3, which fall in the “Low” band, have the highest recurrence during the different seasons, up to more than 70% in some places and situations. The recurrence of AQI10 (very high) is rather small—no more than 5% and concentrated in small areas, mostly in the city center. The Heat index of category “Danger” never appears, and the Heat index of category “Extreme caution” appears only in the spring and summer with the highest recurrence of less than 5% in the city center. For the Wind-chill index category, “Very High Risk” never appears, and the category “High Risk” appears with a frequency of about 1–2%. The above leads to the conclusion that both from a point of view of bioclimatic and air quality indices, the human health risks in the city of Sofia are not as high.

26 June 2014
Verified
Book Chapter
Closed access
PDF file
Georgi GadzhevGeorgi Gadzhev
Georgi Gadzhev
Kostadin GanevKostadin Ganev
Kostadin Ganev
NMNikolay Miloshev
Nikolay Miloshev
DSDimiter Syrakov
Dimiter Syrakov
MPMaria Prodanova
Maria Prodanova

10 May 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
Georgi GadzhevGeorgi Gadzhev
Georgi Gadzhev
Kostadin GanevKostadin Ganev
Kostadin Ganev
PMPlamen Mukhtarov
Plamen Mukhtarov
The present study aims to demonstrate the effects of horizontal grid resolution on the simulated pollution concentration fields over Bulgaria. The computer simulations are performed with a set of models used worldwide—the Weather Research and Forecasting Model (WRF)—the meteorological preprocessor, the Community Multiscale Air Quality Modeling System (CMAQ)—chemical transport model, Sparse Matrix Operator Kernel Emissions (SMOKE)—emission model. The large-scale (background) meteorological data used in the study were taken from the ‘NCEP Global Analysis Data’ with a horizontal resolution of 1° × 1°. Using the ‘nesting’ capabilities of the WRF and CMAQ models, a resolution of 9 km was achieved for the territory of Bulgaria by sequentially solving the task in several consecutive nested areas. Three cases are considered in this paper: Case 1: The computer simulations result from the domain with a horizontal resolution (both of the emission source description and the grid) of 27 km.; Case 2: The computer simulations result from the domain with a horizontal resolution (both of the emission source description and the grid) of 9 km.; Case 3: A hybrid case with the computer simulations performed with a grid resolution of 9 km, but with emissions such as in the 27 km × 27 km domain. The simulations were performed, for all the three cases, for the period 2007–2014 year, thus creating an ensemble large and comprehensive enough to reflect the most typical atmospheric conditions with their typical recurrence. The numerical experiments showed the significant impact of the grid resolution not only in the pollution concentration pattern but also in the demonstrated generalized characteristics. Averaged over a large territory (Bulgaria); however, the performances for cases one and two are quite similar. Bulgaria is a country with a complex topography and with several considerably large point sources. Thus, some of the conclusions made, though based on Bulgarian-specific experiments, may be of general interest.