Brendan Murphy

Mr. Brendan Murphy

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2021 in Science Translational Medicine
Verified
Journal Article
Closed access
NDNicolette Driscoll
Nicolette Driscoll
BEBrian Erickson
Brian Erickson
BMBrendan Murphy
Brendan Murphy
ARAndrew G. Richardson
Andrew G. Richardson
GRGregory Robbins
Gregory Robbins
FVFlavia Vitale
Flavia Vitale
Ti 3 C 2 MXene–based bioelectronics produced through a highly scalable process enable multiscale electrophysiology and stimulation.

21 June 2020 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
BMBrendan Murphy
Brendan Murphy
PMPatrick J. Mulcahey
Patrick J. Mulcahey
NDNicolette Driscoll
Nicolette Driscoll
ARAndrew G. Richardson
Andrew G. Richardson
GRGregory T. Robbins
Gregory T. Robbins
FVFlavia Vitale
Flavia Vitale

31 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
BMBrendan Murphy
Brendan Murphy
BSBrittany H. Scheid
Brittany H. Scheid
QHQuincy Hendricks
Quincy Hendricks
Nicholas ApolloNicholas Apollo
Nicholas Apollo
BLBrian Litt
Brian Litt
FVFlavia Vitale
Flavia Vitale
A low and stable impedance at the skin–electrode interface is key to high-fidelity acquisition of biosignals, both acutely and in the long term. However, recording quality is highly variable due to the complex nature of human skin. Here, we present an experimental and modeling framework to investigate the interfacial impedance behavior, and describe how skin interventions affect its stability over time. To illustrate this approach, we report experimental measurements on the skin–electrode impedance using pre-gelled, clinical-grade electrodes in healthy human subjects recorded over 24 h following four skin treatments: (i) mechanical abrasion, (ii) chemical exfoliation, (iii) microporation, and (iv) no treatment. In the immediate post-treatment period, mechanical abrasion yields the lowest initial impedance, whereas the other treatments provide modest improvement compared to untreated skin. After 24 h, however, the impedance becomes more uniform across all groups (<20 kΩ at 10 Hz). The impedance data are fitted with an equivalent circuit model of the complete skin–electrode interface, clearly identifying skin-level versus electrode-level contributions to the overall impedance. Using this model, we systematically investigate how time and treatment affect the impedance response, and show that removal of the superficial epidermal layers is essential to achieving a low, long-term stable interface impedance.

29 January 2021 in Communications Biology
Verified
Journal Article
Open access
PDF file
NDNicolette Driscoll
Nicolette Driscoll
RRRichard E. Rosch
Richard E. Rosch
BMBrendan Murphy
Brendan Murphy
AAArian Ashourvan
Arian Ashourvan
RVRamya Vishnubhotla
Ramya Vishnubhotla
FVFlavia Vitale
Flavia Vitale
Neurological disorders such as epilepsy arise from disrupted brain networks. Our capacity to treat these disorders is limited by our inability to map these networks at sufficient temporal and spatial scales to target interventions. Current best techniques either sample broad areas at low temporal resolution (e.g. calcium imaging) or record from discrete regions at high temporal resolution (e.g. electrophysiology). This limitation hampers our ability to understand and intervene in aberrations of network dynamics. Here we present a technique to map the onset and spatiotemporal spread of acute epileptic seizures in vivo by simultaneously recording high bandwidth microelectrocorticography and calcium fluorescence using transparent graphene microelectrode arrays. We integrate dynamic data features from both modalities using non-negative matrix factorization to identify sequential spatiotemporal patterns of seizure onset and evolution, revealing how the temporal progression of ictal electrophysiology is linked to the spatial evolution of the recruited seizure core. This integrated analysis of multimodal data reveals otherwise hidden state transitions in the spatial and temporal progression of acute seizures. The techniques demonstrated here may enable future targeted therapeutic interventions and novel spatially embedded models of local circuit dynamics during seizure onset and evolution.

1 August 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
NANicholas V Apollo
Nicholas V Apollo
BMBrendan Murphy
Brendan Murphy
KPKayla Prezelski
Kayla Prezelski
NDNicolette Driscoll
Nicolette Driscoll
ARAndrew G. Richardson
Andrew G. Richardson
FVFlavia Vitale
Flavia Vitale
Implantable neuroelectronic interfaces have enabled breakthrough advances in the clinical diagnosis and treatment of neurological disorders, as well as in fundamental studies of brain function, behavior, and disease. Intracranial electroencephalography (EEG) mapping with stereo-EEG (sEEG) depth electrodes is routinely adopted for precise epilepsy diagnostics and surgical treatment, while deep brain stimulation has become the standard of care for managing movement disorders. Intracortical microelectrode arrays for high-fidelity recordings of neural spiking activity have led to impressive demonstrations of the power of brain-machine interfaces for motor and sensory functional recovery. Yet, despite the rapid pace of technology development, the issue of establishing a safe, long-term, stable, and functional interface between neuroelectronic devices and the host brain tissue still remains largely unresolved. A body of work spanning at least the last 15 years suggests that safe, chronic integration between invasive electrodes and the brain requires a close match between the mechanical properties of man-made components and the neural tissue. In other words, the next generation of invasive electrodes should be soft and compliant, without sacrificing biological and chemical stability. Soft neuroelectronic interfaces, however, pose a new and significant surgical challenge: bending and buckling during implantation that can preclude accurate and safe device placement. In this topical review, we describe the next generation of soft electrodes and the surgical implantation methods for safe and precise insertion into brain structures. We provide an overview of the most recent innovations in the field of insertion strategies for flexible neural electrodes such as dissolvable or biodegradable carriers, microactuators, biologically-inspired support structures, and electromagnetic drives. In our analysis, we also highlight approaches developed in different fields, such as robotic surgery, which could be potentially adapted and translated to the insertion of flexible neural probes.

1 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FVFlavia Vitale
Flavia Vitale
WSWendy Shen
Wendy Shen
NDNicolette Driscoll
Nicolette Driscoll
JBJustin C Burrell
Justin C Burrell
ARAndrew G. Richardson
Andrew G. Richardson
BLBrian Litt
Brian Litt
Intracranial electrodes are a vital component of implantable neurodevices, both for acute diagnostics and chronic treatment with open and closed-loop neuromodulation. Their performance is hampered by acute implantation trauma and chronic inflammation in response to implanted materials and mechanical mismatch between stiff synthetic electrodes and pulsating, natural soft host neural tissue. Flexible electronics based on thin polymer films patterned with microscale conductive features can help alleviate the mechanically induced trauma; however, this strategy alone does not mitigate inflammation at the device-tissue interface. In this study, we propose a biomimetic approach that integrates microscale extracellular matrix (ECM) coatings on microfabricated flexible subdural microelectrodes. Taking advantage of a high-throughput process employing micro-transfer molding and excimer laser micromachining, we fabricate multi-channel subdural microelectrodes primarily composed of ECM protein material and demonstrate that the electrochemical and mechanical properties match those of standard, uncoated controls. In vivo ECoG recordings in rodent brain confirm that the ECM microelectrode coatings and the protein interface do not alter signal fidelity. Astrogliotic, foreign body reaction to ECM coated devices is reduced, compared to uncoated controls, at 7 and 30 days, after subdural implantation in rat somatosensory cortex. We propose microfabricated, flexible, biomimetic electrodes as a new strategy to reduce inflammation at the device-tissue interface and improve the long-term stability of implantable subdural electrodes.