Hideaki Okumichi

Dr. Hideaki Okumichi

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Naoki OkadaNaoki Okada
Naoki Okada
KHKazuyuki Hirooka
Kazuyuki Hirooka
HOHiromitsu Onoe
Hiromitsu Onoe
YMYumiko Murakami
Yumiko Murakami
HOHideaki Okumichi
Hideaki Okumichi
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
We compared surgical outcomes in patients with either primary open-angle glaucoma or exfoliation glaucoma after undergoing combined phacoemulsification with either a 120° or 180° incision during a Schlemm’s canal microhook ab interno trabeculotomy (μLOT-Phaco). This retrospective comparative case series examined 52 μLOT-Phaco eyes that underwent surgery between September 2017 and December 2020. Surgical qualified success was defined as an intraocular pressure (IOP) of ≤20 mmHg, ≥20% IOP reduction with IOP-lowering medications, and no additional glaucoma surgery. Success rates were evaluated by Kaplan-Meier survival analysis. The number of postoperative IOP-lowering medications and occurrence of complications were also assessed. Mean preoperative IOP in the 120° group was 16.9 ± 7.6 mmHg, which significantly decreased to 10.9 ± 2.7 mmHg (p < 0.01) and 11.1 ± 3.1 mmHg (p = 0.01) at 12 and 24 months, respectively. The mean number of preoperative IOP-lowering medications significantly decreased from 2.8 ± 1.4 to 1.4 ± 1.4 (p < 0.01) at 24 months. Mean preoperative IOP in the 180° group was 17.1 ± 7.0 mmHg, which significantly decreased to 12.1 ± 3.2 mmHg (p = 0.02) and 12.9 ± 1.4 mmHg (p = 0.01) at 12 and 24 months, respectively. The mean number of preoperative IOP-lowering medications significantly decreased from 2.9 ± 1.2 to 1.4 ± 1.5 (p < 0.01) at 24 months. The probability of qualified success at 24 months in the 120° and 180° groups was 50.4% and 54.6%, respectively (p = 0.58). There was no difference observed for hyphema formation or IOP spikes. Surgical outcomes were not significantly different between the 120° and 180° incisions in Schlemm’s canal.

23 September 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YNYoshitaka Nakao
Yoshitaka Nakao
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
HOHideaki Okumichi
Hideaki Okumichi
The aim of the study was to investigate the effects of various anatomical structures on intraocular pressure (IOP) measurements obtained by the Corneal Visualization Scheimpflug Technology (Corvis ST), Goldmann applanation tonometer (GAT), and noncontact tonometer (NCT), as well as to assess the interchangeability among the four types of IOP measurement: IOP-GAT, IOP-NCT, IOP-Corvis, and biomechanically corrected IOP (bIOP-Corvis), with a particular focus on bIOP-Corvis. We included 71 patients with primary open-angle glaucoma and assessed their IOP measurements obtained with the GAT, NCT, and Corvis ST using a repeated measures ANOVA, a paired t-test with Bonferroni correction, stepwise multiple regression analyses and Bland–Altman plots. IOP-GAT showed the highest values (13.5 ± 2.1 mmHg [mean ± standard deviation]), followed by IOP-NCT (13.2 ± 2.7 mmHg), IOP-Corvis (10.6 ± 2.8 mmHg), and bIOP-Corvis (10.0 ± 2.3 mmHg). With exceptions of bIOP-Corvis and IOP-GAT, all IOP variations were explained by regression coefficients involving the central corneal thickness. Bland–Altman plots showed a mean difference between IOP-GAT and the other IOP measurements (IOP-Corvis, bIOP-Corvis, and IOP-NCT), which were -2.90, -3.48, and -0.29 mmHg, respectively. The widths of the 95% limits of agreement between all pairs of IOP measurements were greater than 3 mmHg. IOP values obtained with the Corvis ST, NCT, and GAT were not interchangeable. The bIOP-Corvis measurement corrected for the ocular structure.

10 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Naoki OkadaNaoki Okada
Naoki Okada
KHKazuyuki Hirooka
Kazuyuki Hirooka
HOHiromitsu Onoe
Hiromitsu Onoe
HOHideaki Okumichi
Hideaki Okumichi
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
This study retrospectively examined the mid-term surgical outcomes between microhook ab interno trabeculotomy (μLOT) and goniotomy when one was using the Kahook Dual Blade (KDB) in combination with phacoemulsification in primary open-angle glaucoma and exfoliation glaucoma patients. Between December 2016 and December 2020, the current study examined 47 μLOT and 52 KDB eyes that underwent surgery. When there was a < 20% reduction in the preoperative intraocular pressure (IOP) or when the IOP was > 18 mmHg (criterion A), the IOP was > 14 mmHg (criterion B) at two consecutive follow-up visits, or when there was a requirement for reoperation, these were all considered to indicate that the surgery failed. A genetic algorithm that used the preoperative IOP was used to determine the score matching. After score matching, a total of 27 eyes were evaluated. In the μLOT and KDB groups, the mean postoperative follow-up periods were 31.2 ± 13.3 and 37.2 ± 16.3 months, respectively. The results for both of the groups show there were significant postoperative reductions in the IOP (p < 0.05) and medication scores (p < 0.05) at 6, 12, 24 and 36 months. At 12, 24, and 36 months, the probabilities of success in the μLOT and KDB groups for criterion A were 70.4% and 48.2%, 61.9% and 48.2%, and 55.0% and 48.2% (p = 0.32; log-rank test), respectively. For criterion B, the results for the two groups were 55.6% and 33.3%, 44.4% and 33.3%, and 44.4% and 33.3% (p = 0.15; log-rank test), respectively. Similar postoperative complications were found between the groups. Comparable mid-term surgical outcomes were found for the uses of μLOT and KDB.

13 November 2020 in International Ophthalmology
Verified
Journal Article
Open access
PDF file
HOHideaki Okumichi
Hideaki Okumichi
KIKatsumasa Itakura
Katsumasa Itakura
YYyuki yuasa
yuki yuasa
AFAtsuhiko Fukuto
Atsuhiko Fukuto
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
Purpose: To evaluate the fovea in nanophthalmic eyes using spectral domain optical coherence tomography (SD-OCT) and OCT angiography (OCTA), and to investigate the relationship between the macular microstructure and visual acuity. Methods: This is a retrospective case series of five nanophthalmic patients. The foveal avascular zone (FAZ) area was measured in superficial and deep vascular layers with OCTA. The thickness of the inner retinal layer (IRL) was measured with SD-OCT. The ratio of the foveal and parafoveal IRL thickness (fIRL/pIRL ratio) was calculated. The relationship between these parameters and visual acuity was then investigated. Results: Eight eyes were identified as nanophthalmic with a mean axial length of 17.19 ± 1.44 mm (range: 15.71 to 19.88 mm). The mean best-corrected visual acuity (BCVA) in the logarithm of the minimum angle of resolution (logMAR) was 0.12 ± 0.18 (range: − 0.18 to 0.40). OCTA showed that FAZs were either absent or undeveloped in the superficial and deep capillary plexuses. Two patients did not show any visual impairments despite small FAZ and a shallow foveal depression. Although the BCVA was significantly correlated with the deep FAZ size, it did not correlate with the superficial FAZ size, axial length, or fIRL/pIRL ratio. However, the refractive error, axial length, and deep FAZ size were all significantly correlated with the fIRL/pIRL ratio. Conclusions: The FAZs were commonly found to be small in the superficial and deep capillary plexuses. Although the deep FAZ size correlated with visual acuity, it is unclear whether the retinal microstructure and the FAZ size are responsible for the visual impairments observed in the same individuals.

Verified
Journal Article
Open access
PDF file
YYyuki yuasa
yuki yuasa
KHKazuyuki Hirooka
Kazuyuki Hirooka
Naoki OkadaNaoki Okada
Naoki Okada
HOHiromitsu Onoe
Hiromitsu Onoe
YMYumiko Murakami
Yumiko Murakami
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
This study examined glaucoma patients after undergoing combined cataract and minimally invasive glaucoma surgery (MIGS), microhook ab interno trabeculotomy and goniotomy with the Kahook Dual Blade (KDB), or cataract surgery alone, and it then evaluates their vision-related quality of life (VR-QOL) following the procedure. A total of 75 eyes of 75 consecutive glaucoma patients in this prospective cohort study underwent phacoemulsification (Phaco) or phaco and MIGS (Phaco-TLO) between October 2019 and March 2022. In all cases, the National Eye Institute Visual Function Questionnaire (VFQ-25) was used to evaluate the 20 eyes in the Phaco group and the 55 eyes in the Phaco-TLO group before and at 2 months after surgery. There was a significant increase in the visual acuity (logMAR) at 2 months post-operatively (Phaco group; 0.34 ± 0.10 to −0.07 ± 0.1, p < 0.0001, Phaco-TLO group; 0.37 ± 0.43 to 0.09 ± 0.32, p < 0.0001). The median (25–75th percentile) total VFQ scores in the Phaco group before and at 2 months after surgery were 71.1 (62.4–80.6) and 79.4 (69.0–84.0), respectively. (p = 0.006). The median (25–75th percentile) total VFQ scores in the Phaco-TLO group before and at 2 months after surgery were 69.8 (55.3–78.6) and 74.7 (65.1–83.3), respectively. (p = 0.005). Glaucoma patients who underwent not only cataract surgery alone but also combined cataract surgery and MIGS exhibited significant improvement in the VR-QOL.

12 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HOHiromitsu Onoe
Hiromitsu Onoe
KHKazuyuki Hirooka
Kazuyuki Hirooka
HOHideaki Okumichi
Hideaki Okumichi
YMYumiko Murakami
Yumiko Murakami
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
We examined postoperative corneal higher-order aberrations (HOAs) present after combined phacoemulsification with either microhook ab interno trabeculotomy (μLOT-Phaco) or goniotomy, using the Kahook Dual Blade (KDB-Phaco). Retrospective study: A total of 45 eyes underwent μLOT-Phaco and KDB-Phaco (LOT-Phaco) procedures, with 21 eyes that underwent cataract surgery alone used as controls. Visual acuity and corneal HOAs, coma-like aberrations, and spherical-like aberrations were analyzed before and at 1, 2, and 3 months after the surgeries. Risk factors that could potentially influence HOAs were evaluated. No significant postoperative changes were noted for corneal HOAs, coma-like aberrations, and spherical-like aberrations after cataract surgery alone. The mean corneal HOAs, coma-like aberrations, and spherical-like aberrations were 0.222 ± 0.115 μm, 0.203 ± 0.113 μm, and 0.084 ± 0.043 μm at baseline and 0.326 ± 0.195 μm (p < 0.001), 0.302 ± 0.289 μm (p = 0.03), and 0.150 ± 0.115 μm (p < 0.001) at 3 months after LOT-Phaco, respectively. Results of the analysis for risk factors suggested that a longer incision in Schlemm’s canal could influence corneal HOAs, coma-like aberrations, and spherical-like aberrations after LOT-Phaco. Although no significant postoperative changes were observed in corneal HOAs and coma-like or spherical-like aberrations after cataract surgery alone, a significant increase in corneal HOAs and coma-like or spherical-like aberrations remained after the LOT-Phaco procedure.