Christos Davatzikos

Dr. Christos Davatzikos


Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Radiology
Verified
Journal Article
Closed access
AZAlex Zwanenburg
Alex Zwanenburg
MVMartin Vallières
Martin Vallières
MAMahmoud A. Abdalah
Mahmoud A. Abdalah
HAHugo J. W. L. Aerts
Hugo J. W. L. Aerts
VAVincent Andrearczyk
Vincent Andrearczyk
SLSteffen Löck
Steffen Löck
The Image Biomarker Standardization Initiative validated consensus-based reference values for 169 radiomics features, thus enabling calibration and verification of radiomics software. Background Radiomic features may quantify characteristics present in medical imaging. However, the lack of standardized definitions and validated reference values have hampered clinical use. Purpos...

5 September 2017 in Scientific Data
Verified
Journal Article
Open access
PDF file
Spyridon BakasSpyridon Bakas
Spyridon Bakas
HAHamed Akbari
Hamed Akbari
ASAristeidis Sotiras
Aristeidis Sotiras
MBMichel Bilello
Michel Bilello
MRMartin Rozycki
Martin Rozycki
CDChristos Davatzikos
Christos Davatzikos
Gliomas belong to a group of central nervous system tumors, and consist of various sub-regions. Gold standard labeling of these sub-regions in radiographic imaging is essential for both clinical and computational studies, including radiomic and radiogenomic analyses. Towards this end, we release segmentation labels and radiomic features for all pre-operative multimodal magnetic resonance imaging (MRI) (n=243) of the multi-institutional glioma collections of The Cancer Genome Atlas (TCGA), publicly available in The Cancer Imaging Archive (TCIA). Pre-operative scans were identified in both glioblastoma (TCGA-GBM, n=135) and low-grade-glioma (TCGA-LGG, n=108) collections via radiological assessment. The glioma sub-region labels were produced by an automated state-of-the-art method and manually revised by an expert board-certified neuroradiologist. An extensive panel of radiomic features was extracted based on the manually-revised labels. This set of labels and features should enable i) direct utilization of the TCGA/TCIA glioma collections towards repeatable, reproducible and comparative quantitative studies leading to new predictive, prognostic, and diagnostic assessments, as well as ii) performance evaluation of computer-aided segmentation methods, and comparison to our state-of-the-art method.

3 June 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ASAristeidis Sotiras
Aristeidis Sotiras
CDChristos Davatzikos
Christos Davatzikos
NPNikos Paragios
Nikos Paragios
Deformable image registration is a fundamental task in medical image processing. Among its most important applications, one may cite: 1) multi-modality fusion, where information acquired by different imaging devices or protocols is fused to facilitate diagnosis and treatment planning; 2) longitudinal studies, where temporal structural or anatomical changes are investigated; and 3) population modeling and statistical atlases used to study normal anatomical variability. In this paper, we attempt to give an overview of deformable registration methods, putting emphasis on the most recent advances in the domain. Additional emphasis has been given to techniques applied to medical images. In order to study image registration methods in depth, their main components are identified and studied independently. The most recent techniques are presented in a systematic fashion. The contribution of this paper is to provide an extensive account of registration techniques in a systematic manner.

15 April 2003 in The Journal of Neuroscience
Verified
Journal Article
Closed access
PDF file
SRSusan M. Resnick
Susan M. Resnick
DPDzung L. Pham
Dzung L. Pham
MKMichael A. Kraut
Michael A. Kraut
AZAlan B Zonderman
Alan B Zonderman
CDChristos Davatzikos
Christos Davatzikos
Age-related loss of brain tissue has been inferred from cross-sectional neuroimaging studies, but direct measurements of gray and white matter changes from longitudinal studies are lacking. We quantified longitudinal magnetic resonance imaging (MRI) scans of 92 nondemented older adults (age 59–85 years at baseline) in the Baltimore Longitudinal Study of Aging to determine the rates and regional distribution of gray and white matter tissue loss in older adults. Using images from baseline, 2 year, and 4 year follow-up, we found significant age changes in gray (p < 0.001) and white (p < 0.001) volumes even in a subgroup of 24 very healthy elderly. Annual rates of tissue loss were 5.4 ± 0.3, 2.4 ± 0.4, and 3.1 ± 0.4 cm3 per year for total brain, gray, and white volumes, respectively, and ventricles increased by 1.4 ± 0.1 cm3 per year (3.7, 1.3, 2.4, and 1.2 cm3, respectively, in very healthy). Frontal and parietal, compared with temporal and occipital, lobar regions showed greater decline. Gray matter loss was most pronounced for orbital and inferior frontal, cingulate, insular, inferior parietal, and to a lesser extent mesial temporal regions, whereas white matter changes were widespread. In this first study of gray and white matter volume changes, we demonstrate significant longitudinal tissue loss for both gray and white matter even in very healthy older adults. These data provide essential information on the rate and regional pattern of age-associated changes against which pathology can be evaluated and suggest slower rates of brain atrophy in individuals who remain medically and cognitively healthy.

1 July 2017 in NeuroImage
Verified
Journal Article
Open access
RCRastko Ciric
Rastko Ciric
DWDaniel H. Wolf
Daniel H. Wolf
JPJonathan D. Power
Jonathan D. Power
DRDavid R. Roalf
David R. Roalf
GBGraham L. Baum
Graham L. Baum
TSTheodore D. Satterthwaite
Theodore D. Satterthwaite
Since initial reports regarding the impact of motion artifact on measures of functional connectivity, there has been a proliferation of participant-level confound regression methods to limit its impact. However, many of the most commonly used techniques have not been systematically evaluated using a broad range of outcome measures. Here, we provide a systematic evaluation of 14 participant-level confound regression methods in 393 youths. Specifically, we compare methods according to four benchmarks, including the residual relationship between motion and connectivity, distance-dependent effects of motion on connectivity, network identifiability, and additional degrees of freedom lost in confound regression. Our results delineate two clear trade-offs among methods. First, methods that include global signal regression minimize the relationship between connectivity and motion, but result in distance-dependent artifact. In contrast, censoring methods mitigate both motion artifact and distance-dependence, but use additional degrees of freedom. Importantly, less effective de-noising methods are also unable to identify modular network structure in the connectome. Taken together, these results emphasize the heterogeneous efficacy of existing methods, and suggest that different confound regression strategies may be appropriate in the context of specific scientific goals.

1 November 2002 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
DSDinggang Shen
Dinggang Shen
CDChristos Davatzikos
Christos Davatzikos
A new approach is presented for elastic registration of medical images, and is applied to magnetic resonance images of the brain. Experimental results demonstrate very high accuracy in superposition of images from different subjects. There are two major novelties in the proposed algorithm. First, it uses an attribute vector, i.e., a set of geometric moment invariants (GMIs) that are defined on each voxel in an image and are calculated from the tissue maps, to reflect the underlying anatomy at different scales. The attribute vector, if rich enough, can distinguish between different parts of an image, which helps establish anatomical correspondences in the deformation procedure; it also helps reduce local minima, by reducing ambiguity in potential matches. This is a fundamental deviation of our method, referred to as the hierarchical attribute matching mechanism for elastic registration (HAMMER), from other volumetric deformation methods, which are typically based on maximizing image similarity. Second, in order to avoid being trapped by local minima, i.e., suboptimal poor matches, HAMMER uses a successive approximation of the energy function being optimized by lower dimensional smooth energy functions, which are constructed to have significantly fewer local minima. This is achieved by hierarchically selecting the driving features that have distinct attribute vectors, thus, drastically reducing ambiguity in finding correspondence. A number of experiments demonstrate that the proposed algorithm results in accurate superposition of image data from individuals with significant anatomical differences.