Ahmed Hamad

Prof. Dr. Ahmed Hamad

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Energy Engineering
Verified
Journal Article
Open access
AHAhmed Hamad
Ahmed Hamad
FHFawziea M. Hussien
Fawziea M. Hussien
JFJohain J. Faraj
Johain J. Faraj
The fluctuation in drying temperature influences the food products’ quality and drying time significantly during the drying process using an indirect solar dryer. One of the effective methods to reduce these variations in the temperature is based on thermal storage materials to control the drying temperature. An experimental investigation is presented in this study to evaluate the performance of an indirect solar dryer with air double pass using multiple phase change materials (PCM) as thermal storage materials. Two PCMs with different melting points are used to store the available heat energy during peak sunshine periods and reduce the drying temperature fluctuations. Drying tests on a food product sample are conducted in three cases, the first was without PCMs using natural convection. The second and third cases are based on forced convection with and without using multiple PCMs under Baghdad city conditions. The results showed that; approximately a steady temperature of hot drying air was obtained during relatively low ambient temperatures when the dryer was incorporated with multiple PCMs. The drying time of the product sample for the natural, forced convection without PCMs and forced with PCMs was 87, 72 and 47 h, respectively. The higher performance of the dryer was for the forced convection with PCMs. The reduction percentage in drying time was about 17.2% and 46% for the forced convection without and with PCMs respectively compared with natural convection. The average drying rate for the natural, forced without PCMs and forced convection with PCMs was 0.0093, 0.0135 and 0.0172 kg/h, respectively. The enhancement in thermal efficiency of the solar collector and drying chamber with multiple PCMs was 43% and 25.5%, respectively, compared with a typical solar dryer.

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
FKFadhil Abdulrazzaq Kareem
Fadhil Abdulrazzaq Kareem
AKAbdul Hadi N. Khalifa
Abdul Hadi N. Khalifa
AHAhmed Hamad
Ahmed Hamad
In recent decades, adsorption refrigeration systems (ARS) are becoming increasingly popular as one type of environmentally friendly refrigeration system that us In recent decades, adsorption refrigeration systems (ARS) are becoming increasingly popular as one type of environmentally friendly refrigeration system that us

6 August 2021 in Fluids
Verified
Journal Article
Open access
PDF file
AHAhmed Hamad
Ahmed Hamad
One essential utilization of phase change materials as energy storage materials is energy saving and temperature control in air conditioning and indirect solar air drying systems. This study presents an experimental investigation evaluating the characteristics and energy savings of multiple phase change materials subjected to internal flow in an air heating system during charging and discharging cycles. The experimental tests were conducted using a test rig consisting of two main parts, an air supply duct and a room model equipped with phase change materials (PCMs) placed in rectangular aluminum panels. Analysis of the results was based on three test cases: PCM1 (Paraffin wax) placed in the air duct was used alone in the first case; PCM2 (RT–42) placed in the room model was used alone in the second case; and in the third case, the two PCMs (PCM1 and PCM2) were used at the same time. The results revealed a significant improvement in the energy savings and room model temperature control for the air heating system incorporated with multiple PCMs compared with that of a single PCM. Complete melting during the charging cycle occurred at temperatures in the range of 57–60 °C for PCM1 and 38–43 °C for PCM2, respectively, thereby validating the reported PCMs’ melting–solidification results. Multiple PCMs maintained the room air temperature at the desired range of 35–45.2 °C in the air heating applications by minimizing the air temperature fluctuations. The augmentation in discharging time and improvement in the room model temperature using multiple PCMs were about 28.4% higher than those without the use of PCMs. The total energy saving using two PCMs was higher by about 29.5% and 46.7% compared with the use of PCM1 and PCM2, respectively. It can be concluded that multiple PCMs have revealed higher energy savings and thermal stability for the air heating system considered in the current study.

31 August 2025 in Journal of Engineering and Sustainable Development
Verified
Journal Article
Open access
PDF file
ZSZainab Nadeem Suzah
Zainab Nadeem Suzah
AHAhmed Hamad
Ahmed Hamad
AKAbdul Hadi N. Khalifa
Abdul Hadi N. Khalifa
In this study, two techniques to improve the thermal performance of the double-pass solar air heater are experimentally investigated. The first is integrating a phase change material (PCM) as a thermal storage system, and the second is using flow turbulators with the absorber plate to enhance the heat transfer in the solar air heater (SAH). Four different arrangements of the modified SAH absorber plate integrated with and without PCM and flow turbulators with used longitudinal fins on the plate's lower surface are investigated. The modified SAH was examined based on three air flow rates, 0.002, 0.005, and 0.012 kg/s, under Baghdad city climatic conditions. The results demonstrated that the modified double-pass SAH integrated with PCM had a higher performance than the conventional SAH. The outlet air temperature in modified cases 1, 2, and 3 was higher by about 22, 14, and 9%, respectively, compared with the conventional case of flat plate. The flow turbulator of V-shaped revealed optimal performance where the improvement in thermal efficiency was 35% compared with 26% and 19% for other flow turbulators cases 1, and 2, respectively. was observed that the use of PCM increased the operating time by 2 hours after the sunset.

30 June 2023 in Mathematical Modelling of Engineering Problems
Verified
Journal Article
Closed access
AHAhmed Hamad
Ahmed Hamad
FHFawizea M. Hussein
Fawizea M. Hussein
ATAli Lateef Tarish
Ali Lateef Tarish

31 March 2018 in International Review of Mechanical Engineering (IREME)
Verified
Journal Article
Closed access
AHAhmed Hamad
Ahmed Hamad
AKAbdul Hadi N. Khalifa
Abdul Hadi N. Khalifa
DKDoaa Zaid Khalaf
Doaa Zaid Khalaf
This work presents an experimental and numerical investigation of vapor compression refrigeration system performance with variable speed compressor and vapor injection. A test rig of 5 ton capacity split air conditioner equipped, with frequency inverter to control the speed of scroll type compressor, and a secondary capillary tube to expand the refrigerant in the vapor injection circuit are used to conduct the experimental work. Three different vapor injection mass ratios (2, 3, and 4%) are investigated with variable compression speed for frequency range from 35 to 60 Hz. TRNSYS-16 is the software is used to simulate a single zone building conditioned with the modified split air conditioner. The results showed that, the reduction of the compressor speed to the frequency of 35Hz leads to an improvement of the COP by 36% and reduces the power consumption by 18%, compared to the conventional refrigeration system. The usage of the vapour injection with variable speed compressor has improved the COP of the modified system by 47% at 35 Hz and 2% vapour injection ratio. The average improvement in cycle capacity at different compressor speeds is about 24.6%, 28.77% and 34.28% respectively for the vapor injection ratios of 2%, 3& and 4%. It was observed that the reduction of compression speed can extend the compressor lifetime by reducing the ON/OFF cycle of the system at a speed of 35Hz and 2% vapor injection by 17.3%, compared to the conventional system. While at a speed of 60Hz, the ON/OFF cycle has increased by 9.3 and 12% for 2% and 4% injection ratios, respectively. The comparison between the numerical and experimental results of the modified system with vapor injection ratio 2% and 35 Hz compressor speed has displayed an increase in the numerical results around 2.57% for COP, 5.8% for cooling capacity and 5.68% for compressor power consumption. Copyright © 2018 Praise Worthy Prize - All rights reserved.