Christoph Birkl

Dr. Christoph Birkl

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Acta Biomaterialia
Verified
Journal Article
Closed access
SBS. Budday
S. Budday
GSG. Sommer
G. Sommer
CBChristoph Birkl
Christoph Birkl
CLC. Langkammer
C. Langkammer
JHJ. Haybaeck
J. Haybaeck
Gerhard A. HolzapfelGerhard A. Holzapfel
Gerhard A. Holzapfel

2 February 2016 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
CBChristoph Birkl
Christoph Birkl
CLChristian Langkammer
Christian Langkammer
NGNicole Golob‐Schwarzl
Nicole Golob‐Schwarzl
MLMarlene Leoni
Marlene Leoni
JHJohannes Haybaeck
Johannes Haybaeck
SRStefan Ropele
Stefan Ropele

1 October 2019 in NeuroImage
Verified
Journal Article
Closed access
CBChristoph Birkl
Christoph Birkl
ABAnna Maria Birkl-Toeglhofer
Anna Maria Birkl-Toeglhofer
VEVerena Endmayr
Verena Endmayr
RHRomana Höftberger
Romana Höftberger
GKGregor Kasprian
Gregor Kasprian
ARAlexander Rauscher
Alexander Rauscher

5 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CBChristoph Birkl
Christoph Birkl
JDJonathan Doucette
Jonathan Doucette
MFMichael Fan
Michael Fan
EHEnedino Hernández‐Torres
Enedino Hernández‐Torres
ARAlexander Rauscher
Alexander Rauscher
Purpose: The multi‐exponential T2 decay of the MRI signal from cerebral white matter can be separated into short T2 components related to myelin water and long T2 components related to intracellular and extracellular water. In this study, we investigated to what degree the apparent myelin water fraction (MWF) depends on the angle between white matter fibers and the main magnetic field.Methods: Maps of the apparent MWF were acquired using multi‐echo Carr‐Purcell‐Meiboom‐Gill and gradient‐echo spin‐echo sequences. The Carr‐Purcell‐Meiboom‐Gill sequence was acquired with a TR of 1073 ms, 1500 ms, and 2000 ms. The fiber orientation was mapped with DTI. By angle‐wise pooling the voxels across the brain’s white matter, orientation‐dependent apparent MWF curves were generated.Results: We found that the apparent MWF varied between 25% and 35% across different fiber orientations. Furthermore, the selection of the TR influences the apparent MWF.Conclusion: White matter fiber orientation induces a strong systematic bias on the estimation of the apparent MWF. This finding has implications for future research and the interpretation of MWI results in previously published studies.

28 May 2013 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CBChristoph Birkl
Christoph Birkl
CLChristian Langkammer
Christian Langkammer
JHJohannes Haybaeck
Johannes Haybaeck
CEChristina Ernst
Christina Ernst
RSRudolf Stollberger
Rudolf Stollberger
SRStefan Ropele
Stefan Ropele
Purpose: Magnetic resonance relaxation times of most tissues are expected to depend on temperature, which can impact findings in postmortem magnetic resonance imaging or when using magnetic resonance imaging for relaxation‐based thermometry. The purpose of this study was to investigate the exact temperature dependency of the relaxation times T1, T2, T2*, and the magnetization transfer ratio in different structures of the human brain.Methods: To prevent fixation and autolysis effects, this study was performed with fresh postmortem brain tissues. Following autopsy, coronal brain slices from five deceased subjects were subjected to relaxometry at 3T in a temperature range between 4°C and 37°C. Heating of the tissue was achieved by flushing the vacuum packed brain slices with water at a predefined temperature.Results: T1 showed a linear dependency on temperature with the highest temperature coefficient in the cortex (17.4 ms/°C) and the lowest in the white matter (3.4 ms/°C). T2 did not depend on temperature. T2* and magnetization transfer ratio scaled with temperature only in deep gray matter.Conclusion: The temperature coefficient for T1 is higher than expected from previous reports and varies across brain structures. The coefficients obtained in this study can serve as reference for thermometry or for correcting quantitative postmortem magnetic resonance imaging. Magn Reson Med 71:1575–1580, 2014. © 2013 Wiley Periodicals, Inc.

30 April 2019 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
DKDaniel Kor
Daniel Kor
CBChristoph Birkl
Christoph Birkl
SRStefan Ropele
Stefan Ropele
JDJonathan Doucette
Jonathan Doucette
TXTianyou Xu
Tianyou Xu
ARAlexander Rauscher
Alexander Rauscher