Jun Tang

Jun Tang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
zhiqiang Douzhiqiang Dou
zhiqiang Dou
JTJun Tang
Jun Tang
ZLZhiduo Liu
Zhiduo Liu
QSQigong Sun
Qigong Sun
YWYang Wang
Yang Wang
HCHongda Chen
Hongda Chen
Intraocular pressure (IOP) is an essential indicator of the diagnosis and treatment of glaucoma. IOP has an apparent physiological rhythm, and it often reaches its peak value at night. To avoid missing the peak value at night and sample the entire rhythm cycle, the continuous monitoring of IOP is urgently needed. A wearable contact lens IOP sensor based on a platinum (Pt) strain gauge is fabricated by the micro-electro-mechanical (MEMS) process. The structure and parameters of the strain gauge are optimized to improve the sensitivity and temperature stability. Tests on an eyeball model indicate that the IOP sensor has a high sensitivity of 289.5 μV/mmHg and excellent dynamic cycling performance at different speeds of IOP variation. The temperature drift coefficient of the sensor is 33.4 μV/°C. The non-invasive IOP sensor proposed in this report exhibits high sensitivity and satisfactory stability, promising a potential in continuous IOP monitoring.

25 May 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Yue SuYue Su
Yue Su
KMKainan Ma
Kainan Ma
FYFang Yuan
Fang Yuan
JTJun Tang
Jun Tang
MLMing Liu
Ming Liu
XZXu Zhang
Xu Zhang
Wearable and flexible pressure sensors have sparked great interest due to their unique capacity to conformally attach to the surface of the skin and quantify human activities into recordable electric signals. As a result, more and more research efforts are being devoted to developing high-sensitivity and cost-effective flexible sensors for monitoring an individual’s state of activity. Herein, a high-performance flexible piezoresistive sensor was designed and fabricated by combing 2D transition metal carbides, nitrides, and carbonitrides (MXene) with a honeycomb-like structure formed by femtosecond filamentating pulses. The sensing mechanism is attributed to the change of the connecting conductive paths between the top interdigital electrodes and the bottom microstructured films coated with MXene. The obtained sensing device demonstrates high sensitivity of 0.61 kPa−1, relatively short response time, and excellent reliability and stability. Benefiting from the aforementioned extraordinary sensing performance, the sensor can be used with success to monitor tiny physiological signals, detect large deformations during human movement, and distinguish finger gestures, thus demonstrating its broad prospects in physiological analysis systems, health monitoring systems, and human–machine interaction.

19 March 2023 in Advanced Science
Verified
Journal Article
Open access
LZLudan Zhang
Ludan Zhang
YLYamin Li
Yamin Li
LYLintian Yuan
Lintian Yuan
QZQianyi Zhang
Qianyi Zhang
YYYuqing Yan
Yuqing Yan
YWYuguang Wang
Yuguang Wang
Non‐invasive light‐based antibacterial therapy has a good prospect in non‐surgical treatment of peri‐implant infections. However, its applications are severely limited by poor penetration of light into human tissues, leading to unsatisfying outcomes. Moreover, as an essential prerequisite for traditional light therapy, lasers can no longer meet the patients’ needs for convenient treatment at any time. To break through the spatial and temporal limitations of traditional light therapy, a wireless‐powered blue‐light zirconia implant for readily available treatment of peri‐implant infection is proposed. In space, complete irradiation to complex peri‐implant structure is realized by the built‐in wireless‐powered light source, thus improving the efficacy. In time, wireless‐powering allows timely and controllable anti‐infection treatment. Blue micro‐light emitting diodes are used as therapeutic light sources, which effectively kill peri‐implant infection‐related bacteria without exogenous photosensitive agents. Porphyromonas gingivalis biofilm on implant surface can be completely killed after 20 min irradiation in vitro. The bactericidal rate of peri‐implant methicillin‐resistant Staphylococcus aureus infection reaches 99.96 ± 0.03% under 30 min per day blue light exposure in vivo. Within the scope of this study, the treatment of peri‐implant infection with blue‐light implant has preliminary feasibility, giving a new approach to non‐invasive treatment of deep oral infections, including peri‐implant infections.

1 November 2020 in Photobiomodulation, Photomedicine, and Laser Surgery
Verified
Journal Article
Closed access
LZLudan Zhang
Ludan Zhang
YLYamin Li
Yamin Li
QZQian Zhang
Qian Zhang
NDNing Du
Ning Du
XLXuefen Li
Xuefen Li
YWYuguang Wang
Yuguang Wang
Objective: We developed an implantable wireless blue micro light-emitting diode (micro-LED) device and evaluated the utility of continuous antimicrobial blue light (aBL) irradiation emitted from this micro-LED for root canal disinfection. Methods: An implantable wireless blue micro-LED device (peak wavelength: 410 nm, maximum power: 15 mW) was developed to be placed in the root canal. Optical transmission of the device in human dentin tissue was simulated using Monte Carlo ray-tracing method. The bactericidal effect of low-level aBL on planktonic root canal infection-related bacteria [Enterococcus faecalis, methicillin-resistant Streptococcus aureus (MRSA), and Prevotella intermedia] was evaluated by colony counting. The biocompatibility of continuous low-level aBL exposure was evaluated by infrared thermal imaging and cell viability tests. Thirty extracted intact human single-rooted teeth were prepared and the root canals were infected with E. faecalis for 14 days to form biofilm. The infected root canals were randomly divided into three groups (n = 10), and treated with normal saline (group NS), calcium hydroxide (group CH), and micro-LED device (group aBL) for 3 and 7 days. The bactericidal effect of each group was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Results: Monte Carlo simulation showed that blue light irradiation of the micro-LED device decreased exponentially with the light transmission distance through human dentin tissue. Planktonic E. faecalis, MRSA, and P. intermedia were significantly eliminated after irradiation with 432, 36, and 1.35 J/cm2 aBL, respectively (p < 0.05). Infrared thermal imaging and cell viability tests showed that continuous aBL exposure is biocompatible in vitro. CLSM and SEM analyses revealed that the micro-LED device had a greater antimicrobial effect than CH on E. faecalis biofilm in the root canal. Conclusions: The wireless blue micro-LED device is a promising and user-friendly approach for root canal disinfection that will facilitate infection control in the root canal using aBL.

6 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
KLKun Liu
Kun Liu
HCHongda Chen
Hongda Chen
YWYuguang Wang
Yuguang Wang
MWMengqi Wang
Mengqi Wang
JTJun Tang
Jun Tang
Knee osteoarthritis (OA) is a highly prevalent and disabling disease that causes pain and gradual degeneration of the articular cartilage. Phototherapy is a new physiotherapy treatment, more effective and stable than other non-pharmacologic management. Conventional phototherapy devices typically suffer from unintelligent and bulky equipment, while existing phototherapy methods require maintain a certain phototherapy distance. Here, we introduce a wearable flexible phototherapy device worn on a knee for osteoarthritis, incorporating a phototherapy adhesive patch and a control box. The phototherapy adhesive patch is capable of softly laminating onto the curved surfaces of the knee skin to increase the effects of phototherapy. We describe the LED array, constant current drive module, key control module, and power supply module that serve as the foundations for the control box. The weight of the device is only 101.8 g. The irradiance of the device can be adjusted linearly and irradiance of the designed phototherapy device based on LED can reach 13 mW/cm2. The maximum temperature of the surface of the light source is 31.2 °C. The device proposed in this work exhibits satisfactory stability, promising a potential in phototherapy.

1 March 2020 in Optoelectronics Letters
Verified
Journal Article
Closed access
PDF file
YLYa-Min Li
Ya-Min Li
WPWei-Hua Pei
Wei-Hua Pei
JTJun Tang
Jun Tang
YWYu-Guang Wang
Yu-Guang Wang
ZYZhao-Lin Yao
Zhao-Lin Yao
HCHong-Da Chen
Hong-Da Chen