Pascal Bebié

Mr. Pascal Bebié

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PBPascal Bebié
Pascal Bebié
RBRobert Becker
Robert Becker
VCVolker Commichau
Volker Commichau
JDJan Debus
Jan Debus
GDGuenther Dissertori
Guenther Dissertori
AZAgnieszka Zagozdzinska-Bochenek
Agnieszka Zagozdzinska-Bochenek
(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7T Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500MBq, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of 54.2mm and an inner diameter of 114mm. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system’s Coincidence Resolving Time (CRT) and energy resolution are between separate-uncertainty 209.0(3)ps and separate-uncertainty 12.41(02) Full Width at Half Maximum (FWHM) at low activity and separate-uncertainty 326.89(12)ps and separate-uncertainty 20.630(011) FWHM at 550MBq, respectively. The peak sensitivity is ∼1.6. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300MBq. Based on features visible in the acquired images, we estimate the spatial resolution to be ∼2mm in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500MBq.

12 December 2023 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
PBPascal Bebié
Pascal Bebié
WLWerner Lustermann
Werner Lustermann
JDJan Debus
Jan Debus
CRChristian Ritzer
Christian Ritzer
GDGünther Dissertori
Günther Dissertori
BWBruno Weber
Bruno Weber
Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a novel Positron Emission Tomography insert for a $$7\,\hbox {T}$$7T Bruker BioSpec 70/30 Ultra Shield Refrigerated Magnetic Resonance Imaging (MRI) system. It facilitates truly simultaneous quantitative imaging in mice and rats at injected activities as high as $$500\,\hbox {MBq}$$500MBq . Exploitation of the resulting high count rates enables quick image formation at few seconds per frame. In this investigation, key performance parameters of SAFIR-I have been determined according to the evaluations outlined in the National Electrical Manufacturers Association (NEMA) Standards Publication NU 4-2008 (NEMA-NU4) protocol.Results: Using an energy window of 391 to $$601\,\hbox {keV}$$601keV and a Coincidence Timing Window of $$500\,\hbox {ps}$$500ps , the following performance was observed: The average spatial resolution at $$5\,\hbox {mm}$$5mm radial offset (Full Width at Half Maximum) is $$2.54\,\hbox {mm}$$2.54mm when using Filtered Backprojection, 3D Reprojection reconstruction. For the mouse- and rat-like phantoms, the maximal Noise-Equivalent Count Rates (NECRs) are $$1368\,\hbox {kcps}$$1368kcps at the highest tested average effective concentration of $$14.7\,\hbox {MBq}\,\hbox {cc}^{-1}$$14.7MBqcc-1 , and $$713\,\hbox {kcps}$$713kcps at the highest tested average effective concentration of $$1.72\,\hbox {MBq}\,\hbox {cc}^{-1}$$1.72MBqcc-1 , respectively. The NECR peak is not yet reached for either of these cases. The peak sensitivity is $$1.46\,\%$$1.46% . The Image Quality phantom uniformity standard deviation is $$4.8\,\%$$4.8% . The Recovery Coefficient for the $$5\,\hbox {mm}$$5mm rod is $$(1.08 \pm 0.10)$$(1.08±0.10) . The Spill-Over Ratios are $$(0.22 \pm 0.03)$$(0.22±0.03) and $$(0.22 \pm 0.02)$$(0.22±0.02) , for the water- and air-filled cylinder, respectively. An accuracy of $$4.3\,\%$$4.3% was achieved for the quantitative calibration of reconstructed voxel values.Conclusions: The measured performance parameters indicate that the various design goals have been achieved. SAFIR-I offers excellent performance, especially at the high activities it was designed for. This facilitates planned experiments with fast tracer kinetics in small animals. Ways to potentially improve performance can still be explored. Simultaneously, further performance gains can be expected for a forthcoming insert featuring 2.7 times longer axial coverage named Small Animal Fast Insert for MRI detector II (SAFIR-II).