Several single-file systems manufactured using different heat treatment and operated by different kinematics have been released. This study compared the bending resistance and cyclic fatigue resistance of three NiTi files, and examined their phase-transformation behavior. WaveOne Gold Primary (WOG), Reciproc Blue R25 (RPB), and HyFlex EDM OneFile (HDM) were tested (N = 40/instrument). A vertical load was applied to a point 3 mm from the tip, and the stress was measured until a displacement of 3 mm. Tests were conducted at either room temperature (RT: 22 °C) or body temperature (BT: 37 °C) (n = 10). Cyclic fatigue resistance tests were performed in an artificial canal, which had a curvature angle of 40° and a 5-mm radius. Tests were conducted at either RT or BT (n = 10). Instruments were operated according to the manufacturers' instructions. Test results were analyzed using the Kruskal–Wallis and the Mann–Whitney tests. Additional three instruments of each brand were subjected to differential scanning calorimetry (DSC). At RT the bending resistance of three files were not significantly different. However, at BT the bending resistance of RPB was highest, followed by WOG, and HDM (P < 0.05). At RT, RPB demonstrated the longest fracture time, followed by HDM, and WOG (P < 0.05). At BT, HDM had the longest fracture time, followed by RPB, and WOG (P < 0.05). The WOG, RPB consisted of austenite in a considerable proportion, whereas HDM was mainly martensite state at BT. HDM presented superior flexibility and cyclic fatigue resistance at BT.
The effects of the incorporation of sodium-free bioactive glass into glass ionomer cement (GIC) on the demineralized dentin are studied. Four experimental groups with various amounts of BAG in GIC were considered: BG0 group: 0 wt% (control); BG5 group: 5 wt%; BG10 group: 10 wt%; BG20 group: 20 wt%. The GIC surface and GIC-approximated demineralized dentin surfaces were evaluated using field emission scanning electron microscopy (FE–SEM). X-ray diffraction (XRD) analysis was performed to evaluate the chemical changes in the GIC-approximated dentin surface. In addition, a shear bond strength test was performed to evaluate the effects of BAG incorporation on the bond strength of GIC. FE–SEM analysis indicated that BAG-incorporated GICs formed distinct precipitates on their surface. Precipitates were also formed on the GIC-approximated demineralized dentin surface. It was more obvious when the amount of BAG increased. In the XRD analysis, fluorapatitie (FAP) peaks were detected in the BG5, BG10, and BG20 groups. There was no significant difference in the shear bond strength among all experimental groups. BAG-incorporated GIC precipitated FAP crystals underlying demineralized dentin surface without affecting bond strength. This study suggests the possibility of BAG as a beneficial additive in GIC.
2 March 2018 in International Journal of Oral Science
The purpose of this study was to assess the influence of the types and thicknesses of glass ceramic plates on light transmittance and compare the degrees of conversion (DC) of resin cement under the ceramic materials. Three ceramic plates with thicknesses of 0.5, 1.0, 2.0, and 4.0 mm were fabricated from each of five commercial ceramic blocks in shade A2: high-translucency and low-translucency IPS Empress CAD (Emp_HT and Emp_LT); high-translucency and low-translucency IPS e.max CAD (Emx_HT and Emx_LT); and Vita Mark II (Vita). The translucency parameter was obtained using a colorimeter. The light transmittance rate was measured using a photodetector attached to an optical power meter. The DC of a resin cement (Variolink N) underneath the ceramic plates was examined by Fourier transform infrared spectroscopy. The translucency parameter, light transmittance rate, and DC showed significant differences by ceramic type and thickness (P < 0.05). The Emp_HT specimens showed the highest light transmission and DCs, and the Emx_LT showed the least light transmission and the lowest DCs. The high-translucency Empress showed significantly higher DCs than the low-translucency types (P < 0.05), but there was no significant difference in e.max (P > 0.05). Both type and thickness of the glass ceramics significantly influenced the light transmittance and DC of the light-cured resin cement beneath the ceramic of the same shade.
Calcium phosphate cements (CPCs) are synthetic bioactive cements widely used as hard tissue substitutes. Critical limitations of use include their poor mechanical properties and poor anti-washout behaviour. To address those limitations, we combined CPC with genetically engineered elastin-like polypeptides (ELPs). We investigated the effect of the ELPs on the physical properties and biocompatibility of CPC by testing ELP/CPC composites with various liquid/powder ratios. Our results show that the addition of ELPs improved the mechanical properties of the CPC, including the microhardness, compressive strength, and washout resistance. The biocompatibility of ELP/CPC composites was also comparable to that of the CPC alone. However, supplementing CPC with ELPs functionalized with octaglutamate as a hydroxyapatite binding peptide increased the setting time of the cement. With further design and modification of our biomolecules and composites, our research will lead to products with diverse applications in biology and medicine.
This study aimed to evaluate the effect of a novel bioactive glass (BAG)-containing dentin adhesive on the permeability of demineralized dentin. Bioactive glass (85% SiO2, 15% CaO) was fabricated using the sol-gel process, and two experimental dentin adhesives were prepared with 3 wt% silica (silica-containing dentin adhesive; SCA) or BAG (BAG-containing dentin adhesive; BCA). Micro-tensile bond strength (μTBS) test, fracture mode analysis, field-emission scanning electron microscopy (FE-SEM) analysis of adhesive and demineralized dentin, real-time dentinal fluid flow (DFF) rate measurement, and Raman confocal microscopy were performed to compare SCA and BCA. There was no difference in μTBS between the SCA and BCA (p > 0.05). Multiple precipitates were evident on the surface of the BCA, and partial occlusion of dentinal tubules was observed in FE-SEM of BCA-approximated dentin. The DFF rate was reduced by 50.10% after BCA approximation and increased by 6.54% after SCA approximation. Raman confocal spectroscopy revealed an increased intensity of the hydroxyapatite (HA) peak on the dentin surface after BCA application. The novel BAG-containing dentin adhesive showed the potential of both reducing dentin permeability and dentin remineralization.
This study aimed to evaluate the effect of novel experimental light-curing bioactive glass (BAG)-containing varnish on enamel remineralization. An experimental light-curing, BAG-containing varnish and two commercial varnishes (Nupro White Varnish; Dentsply International, York, PA, USA and Tooth Mousse; GC Corporation, Tokyo, Japan) were used. Microhardness tests (n = 3), field emission scanning electron microscopy (FE-SEM) coupled with energy dispersive X-ray spectroscopy (EDS) (n = 5), and X-ray diffraction (XRD) analysis (n = 5) were performed to compare the remineralization effect of three varnishes with and without ultrasonication. The data of microhardness test were analyzed using one-way ANOVA and Tukey’s post hoc comparison (P < 0.05). Microhardness of demineralized enamel increased after the application of three varnishes (P < 0.05). The experimental BAG-containing varnish showed the highest microhardness among the three varnishes (P < 0.05). Ultrasonication decreased microhardness of Tooth Mousse and BAG-containing varnish groups (P < 0.05). FE-SEM and XRD revealed precipitates of hydroxyapatite (HAP) or fluorapatite (FAP) crystals of three varnishes. The novel experimental BAG-containing varnish may be a promising clinical strategy for the remineralization of early carious lesions or demineralized enamel surfaces.