María Carratalá-Tejada

Prof. Dr. María Carratalá-Tejada

Rey Juan Carlos University, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PFPilar Fernández-González
Pilar Fernández-González
AKAikaterini Koutsou
Aikaterini Koutsou
Alicia Cuesta-GómezAlicia Cuesta-Gómez
Alicia Cuesta-Gómez
MCMaría Carratalá-Tejada
María Carratalá-Tejada
JMJuan Carlos Miangolarra-Page
Juan Carlos Miangolarra-Page
Francisco MolinaFrancisco Molina
Francisco Molina
Gait analysis is necessary to diagnose movement disorders. In order to reduce the costs of three-dimensional motion capture systems, new low-cost methods of motion analysis have been developed. The purpose of this study was to evaluate the inter- and intra-rater reliability of Kinovea® and the agreement with a three-dimensional motion system for detecting the joint angles of the hip, knee and ankle during the initial contact phase of walking. Fifty healthy subjects participated in this study. All participants were examined twice with a one-week interval between the two appointments. The motion data were recorded using the VICON Motion System® and digital video cameras. The intra-rater reliability showed a good correlation for the hip, the knee and the ankle joints (Intraclass Correlation Coefficient, ICC > 0.85) for both observers. The ICC for the inter-rater reliability was >0.90 for the hip, the knee and the ankle joints. The Bland–Altman plots showed that the magnitude of disagreement was approximately ±5° for intra-rater reliability, ±2.5° for inter-rater reliability and around ±2.5° to ±5° for Kinovea® versus Vicon®. The ICC was good for the hip, knee and ankle angles registered with Kinovea® during the initial contact of walking for both observers (intra-rater reliability) and higher for the agreement between observers (inter-rater reliability). However, the Bland–Altman plots showed disagreement between observers, measurements and systems (Kinovea® vs. three-dimensional motion system) that should be considered in the interpretation of clinical evaluations.

1 January 2016 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
MGMaría Dolores Gor-García-Fogeda
María Dolores Gor-García-Fogeda
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
MCMaría Carratalá-Tejada
María Carratalá-Tejada
IAIsabel Mª. Alguacil-Diego
Isabel Mª. Alguacil-Diego
Francisco MolinaFrancisco Molina
Francisco Molina

6 November 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
PFPilar Fernández-González
Pilar Fernández-González
MCMaría Carratalá-Tejada
María Carratalá-Tejada
EMEsther Monge-Pereira
Esther Monge-Pereira
SCSusana Collado-Vázquez
Susana Collado-Vázquez
PBPatricia Sánchez-Herrera Baeza
Patricia Sánchez-Herrera Baeza
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
Background: Non-immersive video games are currently being used as technological rehabilitation tools for individuals with Parkinson’s disease (PD). The aim of this feasibility study was to evaluate the effectiveness of the Leap Motion Controller® (LMC) system used with serious games designed for the upper limb (UL), as well as the levels of satisfaction and compliance among patients in mild-to-moderate stages of the disease. Methods: A non-probabilistic sampling of non-consecutive cases was performed. 23 PD patients, in stages II-IV of the Hoehn & Yahr scale, were randomized into two groups: an experimental group (n = 12) who received treatment based on serious games designed by the research team using the LMC system for the UL, and a control group (n = 11) who received a specific intervention for the UL. Grip muscle strength, coordination, speed of movements, fine and gross UL dexterity, as well as satisfaction and compliance, were assessed in both groups pre-treatment and post-treatment. Results: Within the experimental group, significant improvements were observed in all post-treatment assessments, except for Box and Blocks test for the less affected side. Clinical improvements were observed for all assessments in the control group. Statistical intergroup analysis showed significant improvements in coordination, speed of movements and fine motor dexterity scores on the more affected side of patients in the experimental group. Conclusions: The LMC system and the serious games designed may be a feasible rehabilitation tool for the improvement of coordination, speed of movements and fine UL dexterity in PD patients. Further studies are needed to confirm these preliminary findings.

1 January 2015 in Neurología
Verified
Journal Article
Closed access
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
AMA. Molero-Sánchez
A. Molero-Sánchez
MCMaría Carratalá-Tejada
María Carratalá-Tejada
IAI.M. Alguacil-Diego
I.M. Alguacil-Diego
Francisco MolinaFrancisco Molina
Francisco Molina
DTDiego Torricelli
Diego Torricelli

24 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MCMaría Coca-Tapia
María Coca-Tapia
Alicia Cuesta-GómezAlicia Cuesta-Gómez
Alicia Cuesta-Gómez
Francisco MolinaFrancisco Molina
Francisco Molina
MCMaría Carratalá-Tejada
María Carratalá-Tejada
The aim of the present systematic review was to describe the gait pattern in people with multiple sclerosis (MS) by compiling the main findings obtained from studies using three-dimensional capture systems of human movement. The search was carried out in PubMed, Web of Science, Physiotherapy Evidence Database (PEDro), and the Cumulative Index to Nursing and Allied Health (CINAHL) databases. Studies that used three-dimensional gait analysis systems and that analyzed spatiotemporal, kinematic, kinetic, or electromyographic parameters, were included. The quality of the studies was assessed using the Critical Review Form–Quantitative Studies scale. 12 articles were included with 523 (342 women and 181 men) people with a diagnosis of MS. The present work suggests that people with MS have a decrease in speed and stride length, as well as an increase in double-stance intervals during gait. Likewise, it is common to observe a decrease in hip extension during the stance period, a decrease in knee flexion in the swing period, a decrease in ankle dorsiflexion in the initial contact and a decrease in ankle plantar flexion during the pre-swing phase. The subjects with MS decrease the hip extensor moment and the ankle power during the stance period of walking.

1 June 2014 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
MGMaría Dolores Gor-García-Fogeda
María Dolores Gor-García-Fogeda
Francisco MolinaFrancisco Molina
Francisco Molina
Alicia Cuesta-GómezAlicia Cuesta-Gómez
Alicia Cuesta-Gómez
MCMaría Carratalá-Tejada
María Carratalá-Tejada
IAIsabel M. Alguacil-Diego
Isabel M. Alguacil-Diego
JMJuan Carlos Miangolarra-Page
Juan Carlos Miangolarra-Page