Alon Wolf

Dr. Alon Wolf

Biorobotics and Biomechanics Lab (BRML), Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2006
Verified
Conference Paper
Closed access
ADAmir Degani
Amir Degani
HCH. Choset
H. Choset
AWAlon Wolf
Alon Wolf
MZM.A. Zenati
M.A. Zenati
We have developed a novel highly articulated robotic probe (HARP) that can thread through tightly packed volumes without disturbing the surrounding tissues and organs. We use cardiac surgery as the focal application of this work. As such, we have designed the HARP to enter the pericardial cavity through a subxiphoid port. The surgeon can effectively reach remote intrapericardial locations on the epicardium and deliver therapeutic interventions under direct control. Reducing the overall cross-sectional diameter of the mechanism was the main challenge in the design of this device. Our device differs from others in that we use conventional actuation and still have good maneuverability. We have performed simple proof-of-concept clinical experiments to give preliminary validation of the ideas presented here

8 July 2004
Verified
Conference Paper
Closed access
AWAlon Wolf
Alon Wolf
HBH.B. Brown
H.B. Brown
RCR. Casciola
R. Casciola
ACA. Costa
A. Costa
MSM. Schwerin
M. Schwerin
HCH. Choset
H. Choset

1 June 2011 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
YSYoel Shapiro
Yoel Shapiro
AWAlon Wolf
Alon Wolf
KGKosa Gabor
Kosa Gabor

1 August 2005 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
AWAlon Wolf
Alon Wolf
ADAnthony M DiGioia
Anthony M DiGioia
AMAndrew B Mor
Andrew B Mor
BJBranislav Jaramaz
Branislav Jaramaz
Almost all computer-assisted orthopaedic surgery systems that rely on the anterior pelvic plane definition, such as in computed tomography and magnetic resonance image-based, fluoroscopy-based, and nonimage total hip replacement approaches, are derived from identifying two pairs of pelvic bony landmarks: anterior superior iliac spines and the pubic tubercles. Although these systems strive to achieve cup alignment accuracy of approximately 1°, even a minor failure to correctly identify these anatomic landmarks can lead to higher inaccuracies in the final cup alignment. This study shows how to examine the effects of these inaccuracies on the final acetabular cup implant orientation during total hip replacement by generating a kinematic model, which then is simulated. Simulation results indicate that, for example, a total error of 4 mm in measuring the anterior superior iliac spine and the pubic tubercles would result in a final cup orientation of 47° and 27° in abduction and version respectively, resulting in a 2° abduction error and 7° error in version when targeting 45° abduction and 20° version results. These calculations can be repeated for any error values.

1 January 2005 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
AWAlon Wolf
Alon Wolf
BJB Jaramaz
B Jaramaz
BLB Lisien
B Lisien
ADA M DiGioia
A M DiGioia

1 October 2008 in Journal of Biomechanics
Verified
Journal Article
Closed access
AHAmir Haim
Amir Haim
NRNimrod Rozen
Nimrod Rozen
SDSamuel Dekel
Samuel Dekel
NHNachum Halperin
Nachum Halperin
AWAlon Wolf
Alon Wolf