Etienne Harté

Mr. Etienne Harté

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SISivan Isaacs
Sivan Isaacs
EHEtienne Harté
Etienne Harté
Isabel AlvesIsabel Alves
Isabel Alves
Ibrahim AbdulhalimIbrahim Abdulhalim
Ibrahim Abdulhalim
Plasmon waveguide resonance (PWR) sensors exhibit narrow resonances at the two orthogonal polarizations, transverse electric (TE) and transverse magnetic (TM), which are narrower by almost an order of a magnitude than the standard surface plasmon resonance (SPR), and thus the figure of merit is enhanced. This fact is useful for measuring optical anisotropy of materials on the surface and determining the orientation of molecules with high resolution. Using the diverging beam approach and a liquid crystal retarder, we present experimental results by simultaneous detection of TE and TM polarized resonances as well as using fast higher contrast serial detection with a variable liquid crystal retarder. While simultaneous detection makes the system simpler, a serial one has the advantage of obtaining a larger contrast of the resonances and thus an improved signal-to-noise ratio. Although the sensitivity of the PWR resonances is smaller than the standard SPR, the angular width is much smaller, and thus the figure of merit is improved. When the measurement methodology has a high enough angular resolution, as is the one presented here, the PWR becomes advantageous over other SPR modes. The possibility of carrying out exact numerical simulations for anisotropic molecules using the 4 × 4 matrix approach brings another advantage of the PWR over SPR on the possibility of extracting the orientation of molecules adsorbed to the surface. High sensitivity of the TE and TM signals to the anisotropic molecules orientation is found here, and comparison to the experimental data allowed detection of the orientation of lipids on the sensor surface. The molecular orientations cannot be fully determined from the TM polarization alone as in standard SPR, which underlines the additional advantage of the PWR technique.

26 October 2021 in Molecules
Verified
Journal Article
Open access
PDF file
EREstelle Rascol
Estelle Rascol
SVSandrine Villette
Sandrine Villette
EHEtienne Harté
Etienne Harté
Isabel AlvesIsabel Alves
Isabel Alves
Plasmon waveguide resonance (PWR) is a variant of surface plasmon resonance (SPR) that was invented about two decades ago at the University of Arizona. In addition to the characterization of the kinetics and affinity of molecular interactions, PWR possesses several advantages relative to SPR, namely, the ability to monitor both mass and structural changes. PWR allows anisotropy information to be obtained and is ideal for the investigation of molecular interactions occurring in anisotropic-oriented thin films. In this review, we will revisit main PWR applications, aiming at characterizing molecular interactions occurring (1) at lipid membranes deposited in the sensor and (2) in chemically modified sensors. Among the most widely used applications is the investigation of G-protein coupled receptor (GPCR) ligand activation and the study of the lipid environment’s impact on this process. Pioneering PWR studies on GPCRs were carried out thanks to the strong and effective collaboration between two laboratories in the University of Arizona leaded by Dr. Gordon Tollin and Dr. Victor J. Hruby. This review provides an overview of the main applications of PWR and provides a historical perspective on the development of instruments since the first prototype and continuous technological improvements to ongoing and future developments, aiming at broadening the information obtained and expanding the application portfolio.

20 August 2022
Verified
Book Chapter
Closed access
PDF file
ZAZeinab Awada
Zeinab Awada
LDLéo Delmarre
Léo Delmarre
FAFrançoise Argoul
Françoise Argoul
EHEtienne Harté
Etienne Harté
ADAnne Devin
Anne Devin
Boumediene NedjarBoumediene Nedjar
Boumediene Nedjar

1 March 2025 in Physics of Fluids
Verified
Journal Article
Closed access
HZHao Zhang
Hao Zhang
ZZZaicheng Zhang
Zaicheng Zhang
EHEtienne Harté
Etienne Harté
FAFrançoise Argoul
Françoise Argoul
AMAbdelhamid Maali
Abdelhamid Maali
We present a contactless method for measuring the elastic modulus of living human triple-negative breast cancer cells (MDA-MB-231) using the thermal fluctuations of an atomic force microscope (AFM) cantilever. By analyzing the power spectral density (PSD) of the cantilever's thermal fluctuations, we obtain the resonance frequencies of its first three modes at various cell to cantilever separation distances. By comparing measurements on living cells with those on a rigid borosilicate sphere of the same size, we extract the frequency shift caused by the elasto-hydrodynamic coupling between the cantilever fluctuations and the deformations of the cells. We then fit this frequency shift using an elasto-hydrodynamic model that integrates hydrodynamic forces and cell deformation. This approach allows us to determine the elastic modulus values of the living cells for the first three resonant frequencies of the cantilever.