Wenzhao Sun

Dr. Wenzhao Sun


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in Physica Medica
Verified
Journal Article
Open access
WSWenzhao Sun
Wenzhao Sun
ZMZijie Mo
Zijie Mo
YLYongbao Li
Yongbao Li
JXJifeng Xiao
Jifeng Xiao
LJLecheng Jia
Lecheng Jia
XYXin Yang
Xin Yang
The purpose of this study was to accurately predict or classify the beam GPR with an ensemble model by using machine learning for SBRT(VMAT) plans. A total of 128 SBRT VMAT plans with 330 arc beams were retrospectively selected, and 216 radiomics and 34 plan complexity features were calculated for each arc beam. Three models for GPR prediction and classification using support vector machine algorithm were as follows: (1) plan complexity feature-based model (plan model); (2) radiomics feature-based model (radiomics model); and (3) an ensemble model combining the two models (ensemble model). The prediction performance was evaluated by calculating the mean absolute error (MAE), root mean square error (RMSE), and Spearman's correlation coefficient (SC), and the classification performance was measured by calculating the area under the receiver operating characteristic curve (AUC), accuracy, specificity, and sensitivity. The MAE, RMSE and SC at the 2 %/2 mm gamma criterion in the test dataset were 1.4 %, 2.57 %, and 0.563, respectively, for the plan model; 1.42 %, and 2.51 %, and 0.508, respectively, for the radiomics model; and 1.33 %, 2.49 %, and 0.611, respectively, for the ensemble model. The accuracy, specificity, sensitivity, and AUC at the 2 %/2 mm gamma criterion in the test dataset were 0.807, 0.824, 0.681, and 0.854, respectively, for the plan model; 0.860, 0.893, 0.624, and 0.877, respectively, for the radiomics model; and 0.852, 0.871, 0.710, and 0.896, respectively, for the ensemble model. The ensemble model can improve the prediction and classification performance for the GPR of SBRT (VMAT).

28 July 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
LCLi Chen
Li Chen
BHBotian Huang
Botian Huang
XHXiaoyan Huang
Xiaoyan Huang
WCWufei Cao
Wufei Cao
WSWenzhao Sun
Wenzhao Sun
XDXiaowu Deng
Xiaowu Deng
To evaluate the difference of absorbed doses calculated to medium and to water by a Monte Carlo (MC) algorithm based treatment planning system (TPS), and to assess the potential clinical impact to dose prescription. Thirty patients, 10 nasopharyngeal cancer (NPC), 10 lung cancer and 10 bone metastases cases, were selected for this study. For each case, the treatment plan was generated using a commercial MC based TPS and dose was calculated to medium (Dm). The plan was recalculated for dose to water (Dw) using the same Monitor Units (MU) and control points. The differences between Dm and Dw were qualitatively evaluated by dose-volume parameters and by the plan subtraction method. All plans were measured using the MapCheck2, and gamma passing rates were calculated. For NPC and Lung cases, the mean differences between Dw and Dm for the targets were less than 2% and the maximum difference was 3.9%. The maximum difference of D2% for the organs at risk (OARs) was 6.7%. The maximum differences between Dw and Dm were as high as 10% in certain high density regions. For bone metastases cases, the mean differences between Dw and Dm for the targets were more than 2.2% and the maximum difference was 7.1%. The differences between Dw and Dm for the OARs were basically negligible. At 3%&3 mm criterion, the gamma passing rate of Dw plan and Dm plan were close (> 94%). The differences between Dw and Dm has little clinical impact for most clinical cases. In bony structures the differences may become clinically significant if the target/OAR is receiving doses close to its tolerance limit which can potentially influence the selection or rejection of a particular plan.

15 March 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
WSWenzhao Sun
Wenzhao Sun
DZDan-Dan Zhang
Dan-Dan Zhang
YPYinglin Peng
Yinglin Peng
LCLi Chen
Li Chen
DKDe-Hua Kang
De-Hua Kang
XDXiaowu Deng
Xiaowu Deng
Conventional phantom-based planar dosimetry (2D-PBD) quality assurance (QA) using gamma pass rate (GP (%)) is inadequate to reflect clinically relevant dose error in intensity-modulated radiation therapy (IMRT), owing to a lack of information regarding patient anatomy and volumetric dose distribution. This study aimed to evaluate the dose distribution accuracy of IMRT delivery for nasopharyngeal carcinoma (NPC), which passed the 2D-PBD verification, using a measurement-guided 3D dose reconstruction (3D-MGR) method. Radiation treatment plans of 30 NPC cases and their pre-treatment 2D-PBD data were analyzed. 3D dose distribution was reconstructed on patient computed tomography (CT) images using the 3DVH software and compared to the treatment plans. Global and organ-specific dose GP (%), and dose-volume histogram (DVH) deviation of each structure was evaluated. Interdependency between GP (%) and the deviation of the volumetric dose was studied through correlation analysis. The 3D-MGR achieved global GP (%) similar to conventional 2D-PBD in the same criteria. However, structure-specific GP (%) significantly decreased under stricter criteria, including the planning target volume (PTV). The average deviation of all inspected dose volumes (DV) and volumetric dose (VD) parameters ranged from − 2.93% to 1.17%, with the largest negative deviation in V100% of the PTVnx of − 15.66% and positive deviation in D1cc of the spinal cord of 6.66%. There was no significant correlation between global GP (%) of 2D-PBD or 3D-MGR and the deviation of the most volumetric dosimetry parameters (DV or VD), when the Pearson’s coefficient value of 0.8 was used for correlation evaluation. Even upon passing the pre-treatment phantom based dosimetric QA, there could still be risk of dose error like under-dose in PTVnx and overdose in critical structures. Measurement-guided 3D volumetric dosimetry QA is recommended as the more clinically efficient verification for the complicated NPC IMRT.

1 September 2016 in British Journal of Radiology
Verified
Journal Article
Closed access
YCYi-Kan Cheng
Yi-Kan Cheng
LZLei Zeng
Lei Zeng
SYShu-Biao Ye
Shu-Biao Ye
JZJian Zheng
Jian Zheng
ZLZhang Lin
Zhang Lin
LCLei Chen
Lei Chen
To report a novel approach for craniospinal irradiation (CSI) using a supine isocentric technique. Patients were treated in the supine position using CT simulation. Half-beam blocked lateral cranial fields and superior spinal fields have the same isocenter and their beam divergences match. Tangential irradiation provides a non-divergent junction for the other two full-beam spinal fields. Shielding for cranial fields was generated and dose distribution calculated using a three-dimensional planning system. When sacral spinal fields were required, two lateral opposite fields were designed to protect the urogenital organs. All treatment portals were filmed once per week. At a median follow-up of 49.8 months, five relapses and no cases of radiation myelitis developed in 26 consecutive patients. In the junctions of the brain-spine or spine-spine field, no failure occurred. Three failures occurred in the primary site alone, 2 in the spinal axis alone. The results of our study have shown that our novel approach for CSI was not associated with increased failures at the field junction and deaths. In addition, no radiation myelitis, pneumonia, severe damage to heart and gastrointestinal tract, and second cancers occurred in our study. This new approach is an optimal alternative in cancer center without TOMO because of its convenience for immobilization, repeatability, optimal dose distribution and satisfactory clinical outcome.