Christian Torres Reyes

Mr. Christian Torres Reyes

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2025 in Gut
Verified
Journal Article
Open access
PDF file
JDJan Drews
Jan Drews
MZMarkus Zachäus
Markus Zachäus
TKTobias Kleemann
Tobias Kleemann
JSJörg Schirra
Jörg Schirra
OCOscar Cahyadi
Oscar Cahyadi
THThomas von Hahn
Thomas von Hahn
Background Prophylactic application of a haemostatic gel to the resection field may be an easy way to prevent delayed bleeding, a frequent complication after endoscopic mucosal resection (EMR). Objective We aimed to evaluate if the prophylactic application of a haemostatic gel to the resection field directly after EMR can reduce the rate of clinically significant delayed bleeding events. Design We conducted a prospective randomised trial of patients undergoing hot-snare EMR of flat lesions in the duodenum (≥10 mm) and colorectum (≥20 mm) at 15 German centres. Prophylactic clip closure was not allowed, but selective clipping or coagulation could be used prior to randomisation to treat intraprocedural bleeding or for prophylactic closure of visible vessels. Patients were randomised to haemostatic gel application or no prophylaxis. The primary endpoint was delayed bleeding within 30 days. Results The trial was stopped early due to futility after an interim analysis. The primary endpoint was analysed in 232 patients (208 colorectal, 26 duodenal). Both groups were comparable in age, sex, comorbidities and lesion characteristics. Preventive measures, such as selective clipping or coagulation, were applied prior to randomisation in 51.9% of cases, with no difference between groups. Delayed bleeding occurred in 14 cases (11.7%; 95% CI 7.1% to 18.6%) after Purastat and in 7 cases (6.3%; 95% CI 3.1% to 12.3%) in the control group (p=0.227), with no difference between colorectal and duodenal subgroups. Conclusion The application of a haemostatic gel following EMR of large flat lesions in the duodenum and colorectum does not reduce the rate of delayed bleeding.

3 September 2021 in COVID
Verified
Journal Article
Open access
PDF file
CRChristian Torres Reyes
Christian Torres Reyes
ESEike Steinmann
Eike Steinmann
NTNina Timmesfeld
Nina Timmesfeld
HTHans-Joachim Trampisch
Hans-Joachim Trampisch
JSJulien Stein
Julien Stein
WSWolfgang Schmidt
Wolfgang Schmidt
The role of educational facilities, including schools and universities, in the SARS-CoV-2 pandemic is heavily debated. Specifically, the risk of infection in student dormitories has not been studied. This cohort study monitored students living in dormitories in Bochum, Germany, throughout the winter term of 2020/2021. Over the course of four months, participants were tested repeatedly for SARS-CoV-2 infections using RT-PCR from gargle samples and serological testing. An online questionnaire identified individual risk factors. A total of 810 (46.5% female) students participated. Of these, 590 (72.8%) students participated in the final visit. The cross-sectional antibody prevalence was n = 23 (2.8%) in November 2020 and n = 29 (4.9%) in February 2021. Of 2513 gargle samples analyzed, 19 (0.8%) tested positive for SARS-CoV-2, corresponding to 14 (2.4%) infections detected within the study period. Gargle samples available of cases with confirmed present infection were always positive. The person-time incidence rate was 112.7 (95% CI: 54.11–207.2) per 100,000 person weeks. The standardized incidence ratio was 0.9 (95% CI 0.51–1.46, p = 0.69). In conclusion, students living in student dormitories do not appear to be major drivers of SARS-CoV-2 infections. RT-PCR from gargle samples is a patient-friendly and scalable surveillance tool for detection of SARS-CoV-2 infections.

13 January 2026 in Endoscopy International Open
Verified
Journal Article
Open access
OCOscar Cahyadi
Oscar Cahyadi
AEAlanna Ebigbo
Alanna Ebigbo
CRChristian Torres Reyes
Christian Torres Reyes
AZAntonia Zörb
Antonia Zörb
ETElena Theiß
Elena Theiß
PEPeter Ewald
Peter Ewald
Background Workflow interruptions are common in procedural medicine and may increase cognitive load, stress, and the risk of errors. While interruptions and flow disruptions have been studied in surgical settings, little is known about workflow interruptions in endoscopic environments. Objective evaluation of workflow interruptions requires a reliable measurement tool. This study aimed to develop a structured observation tool for recording workflow interruptions during endoscopic procedures and to evaluate its interrater reliability. Methods A structured tally-based observation tool for recording workflow interruptions was developed in an iterative process, and interruptions were categorized into predefined domains. Three independent observers underwent structured training and calibration. A predefined subset of endoscopic procedures was observed simultaneously by two independent observers. Interrater reliability was assessed using intraclass correlation coefficients (ICCs) and Bland–Altman analysis. Results A total of 35 procedures were scheduled for double observation, and 33 procedures were included in the final interrater reliability analysis. Interrater reliability for the total number of interruptions was excellent for both observer pairs (ICC 0.995 for A–B and 0.995 for A–C). Reliability across interruption domains ranged from good to excellent. Bland–Altman analysis demonstrated small mean differences with narrow limits of agreement and no relevant systematic bias. Conclusion This methodologic study demonstrates that workflow interruptions during endoscopic procedures can be measured reliably using a structured tally-based observation tool. The instrument provides a standardized methodologic framework for future studies investigating workflow processes and workflow-focused interventions in endoscopy.