Marijn Jongerden

Dr. Marijn Jongerden

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2009 in IET Software
Verified
Journal Article
Closed access
MJMarijn Jongerden
Marijn Jongerden
BHBoudewijn R. Haverkort
Boudewijn R. Haverkort
The use of mobile devices like cell phones, navigation systems or laptop computers is limited by the lifetime of the included batteries. This lifetime depends naturally on the rate at which energy is consumed; however, it also depends on the usage pattern of the battery. Continuous drawing of a high current results in an excessive drop of residual capacity. However, during intervals with no or very small currents, batteries do recover to a certain extent. The usage pattern of a device can be well modelled with stochastic workload models. However, one still needs a battery model to describe the effects of the power consumption on the state of the battery. Over the years many different types of battery models have been developed for different application areas. In this study we give a detailed analysis of two well-known analytical models, the kinetic battery model (KiBaM) and the so-called diffusion model. We show that the KiBaM is actually an approximation of the more complex diffusion model; this was not known previously. Furthermore, we tested the suitability of these models for performance evaluation purposes, and found that both models are well suited for doing battery lifetime predictions. However, one should not draw conclusions on what is the best usage pattern based on only a few workload traces.

1 June 2007
Verified
Conference Paper
Closed access
LCLucia Cloth
Lucia Cloth
MJMarijn Jongerden
Marijn Jongerden
BHBoudewijn R. Haverkort
Boudewijn R. Haverkort
The usage of mobile devices like cell phones, navigation systems, or laptop computers, is limited by the lifetime of the included batteries. This lifetime depends naturally on the rate at which energy is consumed, however, it also depends on the usage pattern of the battery. Continuous drawing of a high current results in an excessive drop of residual capacity. However, during intervals with no or very small currents, batteries do recover to a certain extend. We model this complex behaviour with an inhomogeneous Markov reward model, following the approach of the so-called kinetic battery model (KiBaM). The state-dependent reward rates thereby correspond to the power consumption of the attached device and to the available charge, respectively. We develop a tailored numerical algorithm for the computation of the distribution of the consumed energy and show how different workload patterns influence the overall lifetime of a battery.

21 June 2010 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
MJMarijn Jongerden
Marijn Jongerden
AMAlexandru Mereacre
Alexandru Mereacre
HBHenrik Bohnenkamp
Henrik Bohnenkamp
BHBoudewijn R. Haverkort
Boudewijn R. Haverkort
JKJoost-Pieter Katoen
Joost-Pieter Katoen
The use of mobile devices is often limited by the battery lifetime. Some devices have the option to connect an extra battery, or to use smart battery-packs with multiple cells to extend the lifetime. In these cases, scheduling the batteries or battery cells over the load to exploit the recovery properties of the batteries helps to extend the overall systems lifetime. Straightforward scheduling schemes, like round-robin or choosing the best battery available, already provide a big improvement compared to a sequential discharge of the batteries. In this paper, we compare these scheduling schemes with the optimal scheduling scheme produced with two different modeling approaches: an approach based on a priced-timed automaton model (implemented and evaluated in Uppaal Cora), as well as an analytical approach (partly formulated as nonlinear optimization problem) for a slightly adapted scheduling problem. We show that in some cases the results of the simple scheduling schemes (round-robin, and best-first) are close to optimal. However, the optimal schedules, computed according to both methods, also clearly show that in a variety of scenarios, the simple schedules are far from optimal.

1 June 2015
Verified
Conference Paper
Closed access
HGHamed Ghasemieh
Hamed Ghasemieh
BHBoudewijn R. Haverkort
Boudewijn R. Haverkort
MJMarijn Jongerden
Marijn Jongerden
ARAnne Remke
Anne Remke
The use of renewable energy in houses and neighbourhoods is very much governed by national legislation and has recently led to enormous changes in the energy market and poses a serious threat to the stability of the grid at peak production times. One of the approaches towards a more balanced grid is, e.g., taken by the German government by subsidizing local storage for solar power. While the main interest of the energy operator and the government is to balance the grid, thereby ensuring its stability, the main interest of the client is twofold: the total cost for electricity should be as low as possible and the house should be as resilient as possible in the presence of power outages. Using local battery storage can help to overcome the effects of power outages. However, the resulting resilience highly depends on the battery usage strategy employed by the controller, taking into account the state of charge of the battery. We present a Hybrid Petri net model of a house (that is mainly powered by solar energy) with a local storage unit, and analyse the impact of different battery usage strategies on its resilience for different production and consumption patterns. Our analysis shows that there is a direct relationship between resilience and flexibility, since increased resilience, i.e., reserving battery capacity for backup, decreases the flexibility of the storage unit.

1 June 2009
Verified
Conference Paper
Closed access
MJMarijn Jongerden
Marijn Jongerden
BHBoudewijn R. Haverkort
Boudewijn R. Haverkort
HBHenrik Bohnenkamp
Henrik Bohnenkamp
JKJoost-Pieter Katoen
Joost-Pieter Katoen
The use of mobile devices is limited by the battery lifetime. Some devices have the option to connect an extra battery, or to use smart battery packs with multiple cells to extend the lifetime. In these cases, scheduling the batteries over the load to exploit recovery properties usually extends the system lifetime. Straightforward scheduling schemes, like round robin or choosing the best battery available, already provide a big improvement compared to a sequential discharge of the batteries. In this paper we compare these scheduling schemes with the optimal scheduling scheme produced with a priced timed automaton battery model (implemented and evaluated in Uppaal Cora). We see that in some cases the results of the simple scheduling schemes are close to optimal. However, the optimal schedules also clearly show that there is still room for improving the battery lifetimes.

9 September 2016 in Energies
Verified
Journal Article
Open access
PDF file
MJMarijn Jongerden
Marijn Jongerden
JHJannik Hüls
Jannik Hüls
ARAnne Remke
Anne Remke
BHBoudewijn R. Haverkort
Boudewijn R. Haverkort
Domestic renewable energy systems, including photovoltaic energy generation, as well as local storage, are becoming increasingly popular and economically feasible, but do come with a wide range of options. Hence, it can be difficult to match their specification to specific customer’s needs. Next to the usage-specific demand profiles and location-specific production profiles, local energy storage through the use of batteries is becoming increasingly important, since it allows one to balance variations in production and demand, either locally or via the grid. Moreover, local storage can also help to ensure a continuous energy supply in the presence of grid outages, at least for a while. Hybrid Petri net (HPN) models allow one to analyze the effect of different battery management strategies on the continuity of such energy systems in the case of grid outages. The current paper focuses on one of these strategies, the so-called smart strategy, that reserves a certain percentage of the battery capacity to be only used in case of grid outages. Additionally, we introduce a new strategy that makes better use of the reserved backup capacity, by reducing the demand in the presence of a grid outage through a prioritization mechanism. This new strategy, called power-save, only allows the essential (high-priority) demand to draw from the battery during power outages. We show that this new strategy outperforms previously-proposed strategies through a careful analysis of a number of scenarios and for a selection of survivability measures, such as minimum survivability per day, number of survivable hours per day, minimum survivability per year and various survivability quantiles.