Damiano Giuseppe Barone

Dr. Damiano Giuseppe Barone

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
ACAlejandro Carnicer-Lombarte
Alejandro Carnicer-Lombarte
SCShao-Tuan Chen
Shao-Tuan Chen
GMGeorge Malliaras
George Malliaras
DBDamiano Giuseppe Barone
Damiano Giuseppe Barone
The implantation of any foreign material into the body leads to the development of an inflammatory and fibrotic process—the foreign body reaction (FBR). Upon implantation into a tissue, cells of the immune system become attracted to the foreign material and attempt to degrade it. If this degradation fails, fibroblasts envelop the material and form a physical barrier to isolate it from the rest of the body. Long-term implantation of medical devices faces a great challenge presented by FBR, as the cellular response disrupts the interface between implant and its target tissue. This is particularly true for nerve neuroprosthetic implants—devices implanted into nerves to address conditions such as sensory loss, muscle paralysis, chronic pain, and epilepsy. Nerve neuroprosthetics rely on tight interfacing between nerve tissue and electrodes to detect the tiny electrical signals carried by axons, and/or electrically stimulate small subsets of axons within a nerve. Moreover, as advances in microfabrication drive the field to increasingly miniaturized nerve implants, the need for a stable, intimate implant-tissue interface is likely to quickly become a limiting factor for the development of new neuroprosthetic implant technologies. Here, we provide an overview of the material-cell interactions leading to the development of FBR. We review current nerve neuroprosthetic technologies (cuff, penetrating, and regenerative interfaces) and how long-term function of these is limited by FBR. Finally, we discuss how material properties (such as stiffness and size), pharmacological therapies, or use of biodegradable materials may be exploited to minimize FBR to nerve neuroprosthetic implants and improve their long-term stability.

28 January 2014 in Cochrane Database of Systematic Reviews
Verified
Journal Article
Closed access
PDF file
DBDamiano Giuseppe Barone
Damiano Giuseppe Barone
TLTheresa A Lawrie
Theresa A Lawrie
MHMichael G Hart
Michael G Hart

26 April 2024 in Nature Materials
Verified
Journal Article
Open access
PDF file
CDChaoqun Dong
Chaoqun Dong
ACAlejandro Carnicer-Lombarte
Alejandro Carnicer-Lombarte
FBFilippo Bonafè
Filippo Bonafè
BHBotian Huang
Botian Huang
SMSagnik Middya
Sagnik Middya
GMGeorge Malliaras
George Malliaras
Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces.

13 September 2019 in Advanced Materials
Verified
Journal Article
Open access
PDF file
ARAmy E. Rochford
Amy E. Rochford
ACAlejandro Carnicer‐Lombarte
Alejandro Carnicer‐Lombarte
VCVincenzo F. Curto
Vincenzo F. Curto
GMGeorge Malliaras
George Malliaras
DBDamiano Giuseppe Barone
Damiano Giuseppe Barone
The development of electronics capable of interfacing with the nervous system is a rapidly advancing field with applications in basic science and clinical translation. Devices containing arrays of electrodes can be used in the study of cells grown in culture or can be implanted into damaged or dysfunctional tissue to restore normal function. While devices are typically designed and used exclusively for one of these two purposes, there have been increasing efforts in developing implantable electrode arrays capable of housing cultured cells, referred to as biohybrid implants. Once implanted, the cells within these implants integrate into the tissue, serving as a mediator of the electrode–tissue interface. This biological component offers unique advantages to these implant designs, providing better tissue integration and potentially long‐term stability. Herein, an overview of current research into biohybrid devices, as well as the historical background that led to their development are provided, based on the host anatomical location for which they are designed (CNS, PNS, or special senses). Finally, a summary of the key challenges of this technology and potential future research directions are presented.

22 January 2018 in Cochrane Database of Systematic Reviews
Verified
Journal Article
Closed access
PDF file
MJMichael D Jenkinson
Michael D Jenkinson
DBDamiano Giuseppe Barone
Damiano Giuseppe Barone
ABAndrew Bryant
Andrew Bryant
LVLuke Vale
Luke Vale
HBHelen Bulbeck
Helen Bulbeck
CWColin Watts
Colin Watts

25 June 2021 in Science Advances
Verified
Journal Article
Open access
PDF file
BWBen J. Woodington
Ben J. Woodington
VCVincenzo F. Curto
Vincenzo F. Curto
YYYi-Lin Yu
Yi-Lin Yu
HMHéctor Martínez-Domínguez
Héctor Martínez-Domínguez
LCLawrence Coles
Lawrence Coles
DBDamiano Giuseppe Barone
Damiano Giuseppe Barone
Electronics that change shape inside the body enable keyhole surgery of spinal implants that can treat severe pain.