Christopher Wu

Christopher Wu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2024 in The American Journal of Surgery
Verified
Journal Article
Closed access
CWChristopher Wu
Christopher Wu
AGAndrea Gillis
Andrea Gillis
BLBrenessa Lindeman
Brenessa Lindeman
HCHerbert Chen
Herbert Chen
JFJessica Fazendin
Jessica Fazendin

20 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
MWMeng-Huang Wu
Meng-Huang Wu
MLMing-Hsueh Lee
Ming-Hsueh Lee
CWChristopher Wu
Christopher Wu
PTPei-I Tsai
Pei-I Tsai
WHWei Bin Hsu
Wei Bin Hsu
YLYen-Yao Li
Yen-Yao Li
Autogenous bone grafts are the gold standard for interbody fusion implant materials; however, they have several disadvantages. Tantalum (Ta) and titanium (Ti) are ideal materials for interbody cages because of their biocompatibility, particularly when they are incorporated into a three-dimensional (3D) porous structure. We conducted an in vitro investigation of the cell attachment and osteogenic markers of self-fabricated uniform porous Ti (20%, 40%, 60%, and 80%), nonporous Ti, and porous Ta cages (n = 6) in each group. Cell attachment, osteogenic markers, and alkaline phosphatase (ALP) were measured. An in vivo study was performed using a pig-posterior-instrumented anterior interbody fusion model to compare the porous Ti (60%), nonporous Ti, and porous Ta interbody cages in 12 pigs. Implant migration and subsidence, determined using plain radiographs, were recorded before surgery, immediately after surgery, and at 1, 3, and 6 months after surgery. Harvested implants were assessed for bone ingrowth and attachment. Relative to the 20% and 40% porous Ti cages, the 60% and 80% cages achieved superior cellular migration into cage pores. Among the cages, osteogenic marker and ALP activity levels were the highest in the 60% porous Ti cage, osteocalcin expression was the highest in the nonporous Ti cage, and the 60% porous Ti cage exhibited the lowest subsidence. In conclusion, the designed porous Ti cage is biocompatible and suitable for lumbar interbody fusion surgery and exhibits faster fusion with less subsidence compared with porous Ta and nonporous Ti cages.

11 July 2023 in The American Journal of Surgery
Verified
Journal Article
Closed access
CWChristopher Wu
Christopher Wu
AGAndrea Gillis
Andrea Gillis
MSMohamad Sidani
Mohamad Sidani
CMChandler Mcleod
Chandler Mcleod
JFJessica Fazendin
Jessica Fazendin
BLBrenessa Lindeman
Brenessa Lindeman

14 July 2024 in World Journal of Surgery
Verified
Journal Article
Closed access
ZSZhixing Song
Zhixing Song
SBSanjana Balachandra
Sanjana Balachandra
CWChristopher Wu
Christopher Wu
RWRongzhi Wang
Rongzhi Wang
PZPolina Zmijewski
Polina Zmijewski
HCHerbert Chen
Herbert Chen

31 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CWChristopher Wu
Christopher Wu
NFNobuei Fukui
Nobuei Fukui
YLYen-Kuang Lin
Yen-Kuang Lin
CLChing-Yu Lee
Ching-Yu Lee
SCShih-Hsiang Chou
Shih-Hsiang Chou
MWMeng-Huang Wu
Meng-Huang Wu
Robotic-arm-assisted unicompartmental knee arthroplasty (RUKA) was developed to increase the accuracy of bone alignment and implant positioning. This retrospective study explored whether RUKA has more favorable overall outcomes than conventional unicompartmental knee arthroplasty (CUKA). A total of 158 patients with medial compartment osteoarthritis were recruited, of which 85 had undergone RUKA with the Mako system and 73 had undergone CUKA. The accuracy of component positioning and bone anatomical alignment was compared using preoperative and postoperative radiograph. Clinical outcomes were evaluated using questionnaires, which the patients completed preoperatively and then postoperatively at six months, one year, and two years. In total, 52 patients from the RUKA group and 61 from the CUKA group were eligible for analysis. The preoperative health scores and Kellgren–Lawrence scores were higher in the RUKA group. RUKA exhibited higher implant positioning accuracy, thus providing a superior femoral implant angle, properly aligned implant placement, and a low rate of overhang. RUKA also achieved higher accuracy in bone anatomical alignment (tibial axis angle and anatomical axis angle) than CUKA, but surgical time was longer, and blood loss was greater. No significant differences were observed in the clinical outcomes of the two procedures.

24 December 2023 in The American Journal of Surgery
Verified
Journal Article
Closed access
CWChristopher Wu
Christopher Wu
MHMichelle Holland
Michelle Holland
ZSZhixing Song
Zhixing Song
RWRongzhi Wang
Rongzhi Wang
AGAndrea Gillis
Andrea Gillis
HCHerbert Chen
Herbert Chen