This paper describes the development and testing of VirtualDose —a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose ’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.
The rapidly increasing number of diagnostic computed tomography (CT) procedures in the recent decades has spurred heightened concern over the potential risk to patients. Although an accurate organ dose assessment tool has now become highly desirable, existing software packages depend on stylized computational phantoms that were originally developed more than 40 years ago, exhibiting very large discrepancies when compared with phantoms that are anatomically realistic. However, past comparative studies did not focus on CT protocols for adult patients. This study was designed to quantitatively compare two types of phantoms, the stylized phantoms and a pair of recently developed RPI-adult male and adult female (RPI-AM and RPI-AF) phantoms, for various CT scanning protocols involving the chest, abdomen-pelvis and chest-abdomen-pelvis. Organ doses were based on Monte Carlo simulations using the MCNPX code and a detailed CT scanner model for the GE LightSpeed 16. Results are presented as ratios of organ doses from the stylized phantoms to those from the RPI phantoms. It is found that, for most organs contained in the scan volume, the ratios were within the range of 0.75-1.16. However, the stomach doses are significantly different and the ratio is found to be up to 1.86 in male phantoms and 2.29 in the female phantoms due to the anatomical differences between the two types of phantoms. Organs that lie near a scan boundary also exhibit a significant relative difference in organ doses between the two types of phantoms. This study concludes that, due to relatively low x-ray energies, CT doses are very sensitive to organ shape, size and position, and thus anatomically realistic phantoms should be used to avoid the dose uncertainties caused by the lack of anatomical realism. The new phantoms, such as the RPI-AM and AF phantoms that are designed using advanced surface meshes, are deformable and will make it possible to match the anatomy of a specific patient leading to further improvement in dose and risk assessments for patients undergoing CT examinations.
Purpose: A 2-m axial field-of-view, total-body PET/CT scanner (uEXPLORER) has been recently developed to provide total-body coverage and ultra-high sensitivity, which together, enables opportunities for in vivo time-activity curve (TAC) measurement of all investigated organs simultaneously with high temporal resolution. This study aims at quantifying the cumulated activity and patient dose of 2-[F-18]fluoro-2-deoxy-D-glucose (F-18 FDG ) imaging by using delayed time-activity curves (TACs), measured out to 8-h post-injection, for different organs so that the comparison between quantifying approaches using short-time method (up to 75 min post-injection) or long-time method (up to 8 h post-injection) could be performed. Methods: Organ TACs of 10 healthy volunteers were collected using total-body PET/CT in 4 periods after the intravenous injection of F-18 FDG. The 8-h post-injection TACs of 6 source organs were fitted using a spline method (based on Origin (version 8.1)). To compare with cumulated activity estimated from spline-fitted curves, the cumulated activity estimated from multi-exponential curve was also calculated. Exponential curve was fitted with shorter series of data consistent with clinical procedure and previous dosimetry works. An 8-h dynamic bladder wall dose model considering 2 voiding were employed to illustrate the differences in bladder wall dose caused by the different measurement durations. Organ absorbed doses were further estimated using Medical Internal Radiation Dose (MIRD) method and voxel phantoms. Results: A short-time measurement could lead to significant bias in estimated cumulated activity for liver compared with long-time-measured spline fitted method, and the differences of cumulated activity were 18.38% on average. For the myocardium, the estimated cumulated activity difference was not statistically significant due to large variation in metabolism among individuals. The average residence time differences of brain, heart, kidney, liver, and lungs were 8.38%, 15.13%, 25.02%, 23.94%, and 16.50% between short-time and long-time methods. Regarding effective dose, the maximum differences of residence time between long-time-measured spline fitted curve and short-time-measured multi-exponential fitted curve was 9.93%. When using spline method, the bladder revealed the most difference in the effective dose among all the investigated organs with a bias up to 21.18%. The bladder wall dose calculated using a long-time dynamic model was 13.79% larger than the two-voiding dynamic model, and at least 50.17% lower than previous studies based on fixed bladder content volume. Conclusions: Long-time measurement of multi-organ TACs with high temporal resolution enabled by a total-body PET/CT demonstrated that the clinical procedure with 20 min PET scan at 1 h after injection could be used for retrospective dosimetry analysis in most organs. As the bladder content contributed the most to the effective dose, a long-time dynamic model was recommended for the bladder wall dose estimation.
To study the shielding effect of radiologists’ eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended.