Mingbiao Chen

Mr. Mingbiao Chen

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2020 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
MCMingbiao Chen
Mingbiao Chen
SLShili Lin
Shili Lin
WSWenji Song
Wenji Song
JLJie Lv
Jie Lv
ZFZiping Feng
Ziping Feng

25 November 2023 in Applied Thermal Engineering
Verified
Journal Article
Closed access
MCMingbiao Chen
Mingbiao Chen
QDQun Du
Qun Du
TYTao Yu
Tao Yu
WSWenji Song
Wenji Song
WLWenye Lin
Wenye Lin
ZFZiping Feng
Ziping Feng

1 August 2009 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
WLWenchang Liu
Wenchang Liu
XKXiang-Yu Kong
Xiang-Yu Kong
MCMingbiao Chen
Mingbiao Chen
JLJing Li
Jing Li
HYHui Yuan
Hui Yuan
QYQingxiang Yang
Qingxiang Yang

27 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
MCMingbiao Chen
Mingbiao Chen
DFDekun Fu
Dekun Fu
WSWenji Song
Wenji Song
ZFZiping Feng
Ziping Feng
Ice slurry is widely used in the field of ice storage air conditioning, district cooling, seafood preservation, and milk processing. Ice generation using supercooled water is efficient, and the system structure is compact. However, a secondary refrigerant cycle is usually used in order to control the wall temperature and to prevent the “ice blocking” problem. Therefore, an ice generation system using supercooled water with a directed evaporating method is proposed and fabricated in order to improve the system performance, which is tested in the experiment. Then, two calculation methods are used to study the performance of entire ice generation system. We concluded that: (1) The system could run steady without “ice blocking” in the condition where the supercooled water temperature was higher than 271.7 K and the velocity was more than 2.1 m/s. The entire system COP could reach 1.6 when the condenser temperature was about 319 K. (2) The system COP could be improved by about 20% if the compressor output power was based on the theoretical refrigerant cycle. The system COP could reach about 2.5 if the proportion of extra power was 3% and the condenser temperature was 308 K. (3) The system COP with a directed evaporating method was about 14% higher than that with an indirected evaporating method. (4) An orthogonal test was built to quantify the influence of different critical parameters. The influence of factors on the system COP were as follows: condenser temperature > water flow > adiabatic compressibility > refrigerant. This work provided a good look at the performance of an ice generation system using supercooled water with a directed evaporating method. It can play an important role in guiding the design of a system of ice generation using supercooled water.

13 April 2022 in International Journal of Energy Research
Verified
Journal Article
Closed access
MCMingbiao Chen
Mingbiao Chen
WSWenji Song
Wenji Song
SLShili Lin
Shili Lin
FBFanfei Bai
Fanfei Bai
ZFZiping Feng
Ziping Feng

31 August 2024 in Chemical Engineering Science
Verified
Journal Article
Closed access
MCMingbiao Chen
Mingbiao Chen
WSWenji Song
Wenji Song
WLWenye Lin
Wenye Lin
ZFZiping Feng
Ziping Feng