Background: The purpose of this study was to assess the effectiveness and safety of a model predictive control (MPC) algorithm for an artificial pancreas system in outpatients with type 1 diabetes. Methods: We searched PubMed, EMBASE, Cochrane Central, and the Web of Science to December 2021. The eligibility criteria for study selection were randomized controlled trials comparing artificial pancreas systems (MPC, PID, and fuzzy algorithms) with conventional insulin therapy in type 1 diabetes patients. The heterogeneity of the overall results was identified by subgroup analysis of two factors including the intervention duration (overnight and 24 h) and the follow-up periods (< 1 week, 1 week to 1 month, and > 1 month). Results: The meta-analysis included a total of 41 studies. Considering the effect on the percentage of time maintained in the target range between the MPC-based artificial pancreas and conventional insulin therapy, the results showed a statistically significantly higher percentage of time maintained in the target range in overnight use (10.03%, 95% CI [7.50, 12.56] p < 0.00001). When the follow-up period was considered, in overnight use, the MPC-based algorithm showed a statistically significantly lower percentage of time maintained in the hypoglycemic range (−1.34%, 95% CI [−1.87, −0.81] p < 0.00001) over a long period of use (> 1 month). Conclusions: Overnight use of the MPC-based artificial pancreas system statistically significantly improved glucose control while increasing time maintained in the target range for outpatients with type 1 diabetes. Results of subgroup analysis revealed that MPC algorithm-based artificial pancreas system was safe while reducing the time maintained in the hypoglycemic range after an overnight intervention with a long follow-up period (more than 1 month).
Hydrophobic acrylic intraocular lens (IOL) is the most popular material in cataract surgery. Posterior capsule opacification (PCO) is a long-term complication of cataract surgery. It can impair vision and adversely affect the prognosis of IOL delamination. The objective of this study was to perform a systematic review and meta-analysis to provide an updated evaluation of long-term complications and visual function after implantation with hydrophobic acrylic and silicone intraocular lenses. PubMed, Embase, and Cochrane Library were searched from January 2000 until March 2021. Randomized controlled trials (RCTs) and retrospective studies were finally included. The main outcomes were PCO value and neodymium-doped yttrium aluminum garnet (Nd : YAG) capsulotomy rate. Subgroup analysis was performed to compare hydrophobic acrylic and silicone IOLs during the follow-up period. Sensitivity analysis was also performed. The meta-analysis included a total of 17 studies. When the follow-up period was considered, the results of the analysis revealed higher PCO value (Group 3: standardized mean difference (SMD), −0.59; 95% confidence interval (CI), −0.90 to −0.28) and Nd : YAG capsulotomy rate (Group 3: risk ratio (RR), 0.60; 95% CI, 0.40–0.89) for hydrophobic acrylic IOLs than silicone IOLs during a long-term (≥6 years) follow-up. In conclusion, both the PCO value and the Nd : YAG capsulotomy rates were higher in hydrophobic acrylic IOLs group than the silicone IOLs group at long-term use (more than 6 years) after implantation.
Background: IVUS is widely used to quantitatively assess coronary artery disease. The purpose of this study was to automatically characterize dense calcium (DC) tissue in the gray scale intravascular ultrasound (IVUS) images using the image textural features. Methods: A total of 316 Gy-scale IVUS and corresponding virtual histology images from 26 patients with acute coronary syndrome who underwent IVUS along with X-ray angiography between October 2009 to September 2014 were retrospectively acquired and analyzed. One expert performed all procedures and assessed their IVUS scans. After image acquisition, the DC candidate and corresponding acoustic shadow regions were automatically determined. Then, nine image-base feature groups were extracted from the DC candidates. In order to reduce the dimensionalities, principal component analysis (PCA) was performed, and selected feature sets were utilized as an input for a deep belief network. Classification results were validated using 10-fold cross validation. Results: The dimensionality of the feature map was efficiently reduced by 50% (from 66 to 33) without any performance decrease using PCA method. Sensitivity, specificity, and accuracy of the proposed method were 92.8 ± 0.1%, 85.1 ± 0.1%, and 88.4 ± 0.1%, respectively (p < 0.05). We found that the window size could largely influence the characterization results, and selected the 5 × 5 size as the best condition. We also validated the performance superiority of the proposed method with traditional classification methods. Conclusions: These experimental results suggest that the proposed method has significant clinical applicability for IVUS-based cardiovascular diagnosis.
29 October 2023 in Biomedical Signal Processing and Control
The segmentation of a skin lesion is regarded as very challenging because of the low contrast between the lesion and the surrounding skin, the existence of various artifacts, and different imaging acquisition conditions. The purpose of this study is to segment melanocytic skin lesions in dermoscopic and standard images by using a hybrid model combining a new hierarchical K‐means and level set approach, called HK‐LS. Although the level set method is usually sensitive to initial estimation, it is widely used in biomedical image segmentation because it can segment more complex images and does not require a large number of manually labelled images. The preprocessing step is used for the proposed model to be less sensitive to intensity inhomogeneity. The proposed method was evaluated on medical skin images from two publicly available datasets including the PH2 database and the Dermofit database. All skin lesions were segmented with high accuracies (>94%) and Dice coefficients (>0.91) of the ground truth on two databases. The quantitative experimental results reveal that the proposed method yielded significantly better results compared to other traditional level set models and has a certain advantage over the segmentation results of U‐net in standard images. The proposed method had high clinical applicability for the segmentation of melanocytic skin lesions in dermoscopic and standard images.
Background: Liver cancer has a high mortality rate worldwide, and clinicians segment liver vessels in CT images before surgical procedures. However, liver vessels have a complex structure, and the segmentation process is conducted manually, so it is time-consuming and labor-intensive. Consequently, it would be extremely useful to develop a deep learning-based automatic liver vessel segmentation method. Method: As a segmentation method, UNet is widely used as a baseline, and a multi-scale block or attention module has been introduced to extract context information. In recent machine learning efforts, not only has the global context extraction been improved by introducing Transformer, but a method to reinforce the edge area has been proposed. However, the data preprocessing step still commonly uses general augmentation methods, such as flip, rotation, and mirroring, so it does not perform robustly on images of varying brightness or contrast levels. We propose a method of applying image augmentation with different HU windowing values. In addition, to minimize the false negative area, we propose TransRAUNet, which introduces a reverse attention module (RAM) that can focus edge information to the baseline TransUNet. The proposed architecture solves context loss for small vessels by applying edge module (RAM) in the upsampling phase. It can also generate semantic feature maps that allows it to learn edge, global context, and detail location by combining high-level edge and low-level context features. Results: In the 3Dricadb dataset, the proposed model achieved a DSC of 0.948 and a sensitivity of 0.944 in liver vessel segmentation. This study demonstrated that the proposed augmentation method is effective and robust by comparisons with the model without augmentation and with the general augmentation method. Additionally, an ablation study showed that RAM has improved segmentation performance compared to TransUNet. Compared to prevailing state-of-the-art methods, the proposed model showed the best performance for liver vessel segmentation. Conclusions: TransRAUnet is expected to serve as a navigation aid for liver resection surgery through accurate liver vessel and tumor segmentation.