Anton Enders

Mr. Anton Enders

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2018 in Small
Verified
Journal Article
Closed access
PDF file
AEAnton Enders
Anton Enders
ISIna G. Siller
Ina G. Siller
KUKatharina Urmann
Katharina Urmann
MHMichael R. Hoffmann
Michael R. Hoffmann
JBJanina Bahnemann
Janina Bahnemann

2 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
ISIna Siller
Ina Siller
AEAnton Enders
Anton Enders
TSTobias Steinwedel
Tobias Steinwedel
NENiklas-Maximilian Epping
Niklas-Maximilian Epping
MKMarline Kirsch
Marline Kirsch
JBJanina Bahnemann
Janina Bahnemann
With growing advances in three-dimensional (3D) printing technology, the availability and diversity of printing materials has rapidly increased over the last years. 3D printing has quickly become a useful tool for biomedical and various laboratory applications, offering a tremendous potential for efficiently fabricating complex devices in a short period of time. However, there still remains a lack of information regarding the impact of printing materials and post-processing techniques on cell behavior. This study introduces real-time live-cell imaging technology as a fast, user-friendly, and high-throughput screening strategy to verify the in vitro biocompatibility of 3D printed materials. Polyacrylate-based photopolymer material was printed using high-resolution 3D printing techniques, post-processed using three different procedures, and then analyzed with respect to its effects on cell viability, apoptosis, and necrosis of adipogenic mesenchymal stem cells (MSCs). When using ethanol for the post-processing procedure and disinfection, no significant effects on MSCs could be detected. For the analyses a novel image-based live-cell analysis system was compared against a biochemical-based standard plate reader assay and traditional flow cytometry. This comparison illustrates the superiority of using image-based detection of in vitro biocompatibility with respect to analysis time, usability, and scientific outcome.

31 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
AEAnton Enders
Anton Enders
JPJohn-Alexander Preuß
John-Alexander Preuß
JBJanina Bahnemann
Janina Bahnemann
The development of continuous bioprocesses—which require cell retention systems in order to enable longer cultivation durations—is a primary focus in the field of modern process development. The flow environment of microfluidic systems enables the granular manipulation of particles (to allow for greater focusing in specific channel regions), which in turn facilitates the development of small continuous cell separation systems. However, previously published systems did not allow for separation control. Additionally, the focusing effect of these systems requires constant, pulsation-free flow for optimal operation, which cannot be achieved using ordinary peristaltic pumps. As described in this paper, a 3D printed cell separation spiral for CHO-K1 (Chinese hamster ovary) cells was developed and evaluated optically and with cell experiments. It demonstrated a high separation efficiency of over 95% at up to 20 × 106 cells mL−1. Control over inlet and outlet flow rates allowed the operator to adjust the separation efficiency of the device while in use—thereby enabling fine control over cell concentration in the attached bioreactors. In addition, miniaturized 3D printed buffer devices were developed that can be easily attached directly to the separation unit for usage with peristaltic pumps while simultaneously almost eradicating pump pulsations. These custom pulsation dampeners were closely integrated with the separator spiral lowering the overall dead volume of the system. The entire device can be flexibly connected directly to bioreactors, allowing continuous, pulsation-free cell retention and process operation.

5 May 2025 in Advanced Sensor Research
Verified
Journal Article
Open access
CHChristopher Heuer
Christopher Heuer
AEAnton Enders
Anton Enders
SWSteffen Winkler
Steffen Winkler
MKMartin Klaßen
Martin Klaßen
TTThorsten Teutenberg
Thorsten Teutenberg
JBJanina Bahnemann
Janina Bahnemann
In order to screen for optimal bioprocess parameters at higher throughput, researchers developing new biopharmaceuticals are increasingly turning to miniaturized cultivation systems with reduced space and media consumption. However, these systems still face challenges related to the continuous monitoring of critical bioprocess parameters, in particular, because sensor integration is often difficult, and sample volumes for offline measurements are limited. In this work, a novel 3D‐printed microfluidic lab‐on‐a‐chip sensor platform is presented, specifically designed to be compatible with a range of cultivation systems (including shake flasks, bioreactors, and custom microbioreactors). The microfluidic system acts as a miniaturized bypass, integrating sensors for real‐time monitoring of key bioprocess parameters (such as pH, pO₂, pCO₂, glucose, and lactate) without compromising culture volume. This system has been successfully applied in a proof‐of‐concept for the cultivation of Escherichia coli and Saccharomyces cerevisiae. In addition, this platform also includes an integrated sampling unit for small‐volume collection, thereby potentially enabling the analysis of complex analyte mixtures such as amino acids or recombinant proteins. The presented system thus represents a valuable tool for both real‐time online monitoring and offline analysis, contributing to the optimization of biopharmaceutical production processes.