In November 2022, the China Space Station (CSS) was equipped with a cold atomic microwave clock and a Sr optical lattice clock with stabilities of and (where is the integration time in seconds), respectively, which provides an excellent opportunity to test gravitational redshift (GRS) with higher accuracy than previous results. Based on high-precision frequency links between the China Space Station and a ground station, we formulated a model and provided simulation experiments to test GRS. Simulation results suggest that this method could test the GRS at the accuracy level of , more than 2 orders in magnitude higher than the result of the experiment of a hydrogen clock on board a flying rocket more than 40 years ago.
Space-based atomic clocks provide unique conditions for testing General Relativity (GR) due to their stability in a low-disturbance environment and their exposure to significant variations in gravitational potential. Gravitational redshift (GRS), a direct consequence of the Einstein Equivalence Principle (EEP), causes clocks at different gravitational potentials to experience relative time dilation. Ground-to-space GRS experiments measure frequency shifts arising from differences in gravitational potential through signal exchange between ground and satellite clocks. While past experiments have relied on microwave links for time–frequency comparisons, optical time and frequency transfer has recently emerged as a promising alternative due to its immunity to ionospheric effects, reduced sensitivity to atmospheric delays, higher modulation bandwidth, and improved signal clarity. In this work, we investigate the GRS using ground-to-space observations from the Time Transfer by Laser Link (T2L2) experiment onboard the Jason-2 mission. Relative to the pioneering 1975 University of Maryland experiment, USA, the T2L2 mission achieves over an order-of-magnitude improvement in measurement precision, demonstrating the power of modern optical time transfer techniques. By comparing a ground-based hydrogen maser and a space-based ultra-stable quartz oscillator, with respective stabilities of $$10^{-15}$$ and $$10^{-13}$$ at 1000s, over 47 independent T2L2/Jason-2 passes (approximately 12 h total), we obtain a GRS deviation from GR of $$(-0.77 \pm 3.54) \times 10^{-3}$$ . These results demonstrate that optical time-transfer links can achieve high-precision tests of GR, underscoring their potential for future space-based optical timing missions.
The Atomic Clock Ensemble in Space (ACES) mission, currently operating aboard the International Space Station (ISS), is designed to provide high-precision time and frequency measurements and to test fundamental aspects of relativistic physics. Gravitational redshift (GRS), a fundamental prediction of General Relativity (GR), implies that clocks positioned at different gravitational potentials experience relative time dilation. Previous GRS experiments have focused primarily on microwave technologies, with negligible experimental coverage in the optical domain, particularly for ground-to-space links. Motivated by the European Laser Timing (ELT) experiment and the high-precision laser-cooled cesium clock aboard ACES, we introduce and evaluate an optical time-transfer method designed to achieve high-accuracy measurements of GRS. In the absence of actual ELT/ACES optical data, a high-fidelity numerical simulation framework was developed to assess the performance of this method. The framework incorporates representative ELT/ACES mission parameters, including the space-based cesium clock and the H-MASER clock located at the reference ground station, both providing frequency stability at the level of for 1000 s averaging time. Applying a filtering criterion, we obtain a simulated dataset comprising 33 ELT/ACES passes, representing a total observation time of 4.38 h over a single week. Analysis of this high-fidelity dataset reveals a GRS deviation from GR of , achieving a 3.4 orders of magnitude improvement over the best previous laser-ranging experiment conducted at the University of Maryland (UMD), USA, 51 years ago. These simulation results demonstrate that the optical time-transfer link constitutes a powerful tool for testing fundamental physics and, when combined with next-generation optical atomic clocks, enables unprecedented capabilities in space-based timekeeping and geoscience applications.
According to general relativity theory, a precise clock runs at different rates at positions with different geopotentials. Atomic Clock Ensemble in Space (ACES) is a mission using high-performance clocks and links to test fundamental laws of physics in space. The ACES microwave link (MWL) will make the ACES clock signal available to ground laboratories equipped with atomic clocks. The ACES-MWL will allow space-to-ground and ground-to-ground comparisons of atomic frequency standards. This study aims to apply the tri-frequency combination (TFC) method to determine the geopotential difference between the ACES and a first order triangulation station in Egypt. The TFC uses the uplink of carrier frequency 13.475 GHz (Ku band) and downlinks of carrier frequencies 14.70333 GHz (Ku band) and 2248 MHz (S-band) to transfer time and frequency. Here we present a simulation experiment. In this experiment, we use the international space station (ISS) orbit data, ionosphere and troposphere models, regional gravitational potential and geoid for Africa, solid Earth tide model, and simulated clock data by a conventionally accepted stochastic noises model. The scientific object requires stabilities of atomic clocks at least 3 × 10 −16 /day, so we must consider various effects, including the Doppler effect, second-order Doppler effect, atmospheric frequency shift, tidal effects, refraction caused by the atmosphere, and Shapiro effect, with accuracy levels of decimetres. This study is supported by the National Natural Science Foundations of China (NSFC) under Grants 42030105, 41721003, 41804012, 41631072, 41874023, Space Station Project (2020)228, and the Natural Science Foundation of Hubei Province of China under Grant 2019CFB611.
High accuracy and stability of time and frequency transfer links are significant to realizing high-precision time synchronization in geodesy, navigation, and metrology. Also, the current and future challenges for space and ground geodetic observatories are to transfer high-stability time and frequency signals between remote locations. Therefore, future optical spatial links, such as Laser Time Transfer (LTT) on China Space Station (CSS) which will equip with atomic clocks and optical clocks with stabilities of 2 × 10−16 and 8 × 10−18, respectively, are a promising technique for high-precision time transfer links, because laser time transfer links are highly accurate, with fewer delays, and unambiguous observable compared to microwave domain links. The most promising applications for optical time transfer links and optical clocks are fundamental physics and relativistic geodesy. For instance, gravitational redshift test and determination of relativistic geoid. Based on the gravitational frequency shift effect predicted by General Relativity Theory (GRT), this study discusses an approach for determining the gravitational potential difference between optical-atomic clocks onboard China Space Station (CSS) and ground station via optical time transfer link, which could have potential applications in geoscience. For testing purposes, we will use the observations of the Time Transfer by Laser Link (T2L2) on the Jason-2 mission to evaluate the performances of the data analysis algorithm. This study is supported by the National Natural Science Foundations of China (NSFC) under Grants 42030105, 41721003, 41804012, 41974034, 41631072, 41874023, Space Station Project (2020)228, and the Natural Science Foundation of Hubei Province of China under Grant 2019CFB611.
Establishing an International Height Reference Frame (IHRF) has been a major goal of the International Association of Geodesy (IAG) for a long time. The scope of this study is to define a unified height system for Africa using the advantages of relativistic geodetic approaches via spatial time-frequency links. We propose a ground clock network connected with the ACES (Atomic clocks ensemble in Space) by frequencies transfer. The gravitational potential of the ACES will be determined using a gravity field model. The ground stations include stationary clocks as the backbone of the frame. Frequency transfer between the ACES and these stations will be simulated. The gravitational potential differences between the ACES and the ground stations will be computed using the tri-frequency combination method. Finally, the gravitational potential of the ground stations will be determined and converted to orthometric height. The TFC uses the uplink of carrier frequency 13.475 GHz (Ku band) and downlinks of carrier frequencies 14.70333 GHz (Ku band) and 2248 MHz (S-band) to transfer frequency signals. Here we present a simulation experiment. In this experiment, we use the international space station (ISS) orbit data, ionosphere and troposphere models, regional gravitational potential and geoid for Africa, solid Earth tide model, and simulated clock data by a conventionally accepted stochastic noises model. We consider various effects, including the Doppler effect, second-order Doppler effect, atmospheric frequency shift, tidal effects, refraction caused by the atmosphere, and Shapiro effect, with accuracy levels of decimetres. This study is supported by the National Natural Science Foundations of China (NSFC) under Grants 42030105, 41721003, 41804012, 41631072, 41874023, Space Station Project (2020)228, and the Natural Science Foundation of Hubei Province of China under Grant 2019CFB611.